| Company Information | ||||||||
| [email protected] | ||||||||
| Mobile | +8613666033393 | |||||||
| +8613666033393 | ||||||||
| 13666033393 | ||||||||
| Add | Room 1004, No. 62 Xiangxiu Li, Siming District, Xiamen City, Fujian Province, China | |||||||
Yokogawa ACM22 RS-422/485 Communication Module
- Product Details
- FAQs
- Related
- Contact Us
- Packing & Delivery
- Product Ratings
Product Introduction
The Yokogawa ACM22 RS-422/485 Communication Module is a high-performance serial communication interface for integration with Yokogawa CENTUM CS 3000 and compatible control systems. It provides reliable RS-422/485 communication between controllers, field devices, and third-party devices. The module enables seamless system expansion and integration with minimal configuration effort.
Product Advantages
-
Stable and noise-resistant RS-422/485 communication.
-
Flexible configuration for point-to-point and multi-drop topologies.
-
High compatibility with Yokogawa FCS and ESB systems.
-
Robust design suitable for industrial environments.
-
Easy maintenance with modular plug-in structure.
-
Built-in diagnostics with LED indicators for quick troubleshooting.
Technical Specifications
| Parameter | Description |
|---|---|
| Model | Yokogawa ACM22 |
| Communication Interface | RS-422 / RS-485 |
| Supported Protocols | Modbus RTU, Yokogawa proprietary |
| Communication Speed | 300 bps to 115.2 kbps |
| Topology | Point-to-point, multi-drop |
| Isolation | Optical and galvanic isolation |
| Power Supply Voltage | 5 V DC |
| Power Consumption | 1.5 W |
| Diagnostic Indicators | Link, TX/RX, and status LEDs |
| Operating Temperature | 0 to 50°C |
| Storage Temperature | -20 to 70°C |
| Humidity Range | 10 to 90% RH non-condensing |
| Mounting | DIN rail or backplane |
| Dimensions | 125 x 130 x 248 mm |
| Weight | 0.14 kg |
Product Applications
-
Power generation and distribution networks for intelligent relays and meters
-
Oil and gas plants for serial communication with field devices
-
Chemical and petrochemical facilities connecting analyzers and PLCs
-
Water and wastewater treatment systems for remote data acquisition
-
Manufacturing automation systems requiring reliable RS-485 networks
FAQ
Q1: What communication protocols does the ACM22 support?
A1: It supports Modbus RTU and Yokogawa proprietary protocols over RS-422 and RS-485 interfaces.
Q2: Can the ACM22 operate in both half-duplex and full-duplex modes?
A2: Yes, configuration allows operation in either mode depending on network setup.
Q3: Is electrical isolation provided between communication ports and the system bus?
A3: Yes, both optical and galvanic isolation are implemented to prevent interference.
Q4: What is the maximum RS-485 communication distance?
A4: Up to 100 meters using shielded twisted-pair cables.
Q5: Can the ACM22 communicate with third-party PLCs?
A5: Yes, as long as the PLC supports Modbus RTU or RS-485 standards.
Q6: What baud rates are supported?
A6: 300 bps to 115.2 kbps, configurable via engineering software.
Q7: Is there any special configuration required for multi-drop RS-485 lines?
A7: Yes, proper termination resistors and unique node addresses are required.
Q8: Does ACM22 support redundant system configurations?
A8: Yes, it can be integrated into redundant systems for continuous operation.
Q9: How is module status monitored during operation?
A9: LEDs indicate link, transmission, and error status for on-site diagnostics.
Q10: Can firmware updates be performed without shutting down the system?
A10: Yes, updates are applied via the engineering tool with minimal communication interruption.
Related or Same-Series Models
| Model | Description |
|---|---|
| ACM11 | RS-232 Communication Module |
| ACM12 | RS-422/485 Dual Channel Module |
| ACM21 | Multi-protocol Communication Interface |
| ACM23 | High-speed RS-485 Module |
| ACM24 | RS-422/485 Module with extended diagnostics |
| ACM25 | Dual-port Communication Module for redundancy |
Popular Yokogawa Models
| Model | Description | Communication Type / Function |
|---|---|---|
| AAI141 | Analog Input Module | 16-channel analog input |
| AAI543 | Analog Input Module | High-accuracy analog acquisition |
| ADV151 | Digital Output Module | 16-channel discrete output |
| ANB10D | Node Interface Unit | FCS network interface |
| AIP827-32 | Analog Input Module | Redundant high-performance module |
| AMM22 S3 | Analog Multiplexer Module | 16-channel analog multiplexer |
| AIP504-51 | Net Coupler Module | Ethernet network interface |
| ANT411-50 | ESB Bus Repeater Module | Extends ESB communication range |
FAQ
Q1: What communication protocols does the ACM22 support?
A1: It supports Modbus RTU and Yokogawa proprietary protocols over RS-422 and RS-485 interfaces.
Q2: Can the ACM22 operate in both half-duplex and full-duplex modes?
A2: Yes, configuration allows operation in either mode depending on network setup.
Q3: Is electrical isolation provided between communication ports and the system bus?
A3: Yes, both optical and galvanic isolation are implemented to prevent interference.
Q4: What is the maximum RS-485 communication distance?
A4: Up to 100 meters using shielded twisted-pair cables.
Q5: Can the ACM22 communicate with third-party PLCs?
A5: Yes, as long as the PLC supports Modbus RTU or RS-485 standards.
Q6: What baud rates are supported?
A6: 300 bps to 115.2 kbps, configurable via engineering software.
Q7: Is there any special configuration required for multi-drop RS-485 lines?
A7: Yes, proper termination resistors and unique node addresses are required.
Q8: Does ACM22 support redundant system configurations?
A8: Yes, it can be integrated into redundant systems for continuous operation.
Q9: How is module status monitored during operation?
A9: LEDs indicate link, transmission, and error status for on-site diagnostics.
Q10: Can firmware updates be performed without shutting down the system?
A10: Yes, updates are applied via the engineering tool with minimal communication interruption.
Related or Same-Series Models
| Model | Description |
|---|---|
| ACM11 | RS-232 Communication Module |
| ACM12 | RS-422/485 Dual Channel Module |
| ACM21 | Multi-protocol Communication Interface |
| ACM23 | High-speed RS-485 Module |
| ACM24 | RS-422/485 Module with extended diagnostics |
| ACM25 | Dual-port Communication Module for redundancy |
Popular Yokogawa Models
| Model | Description | Communication Type / Function |
|---|---|---|
| AAI141 | Analog Input Module | 16-channel analog input |
| AAI543 | Analog Input Module | High-accuracy analog acquisition |
| ADV151 | Digital Output Module | 16-channel discrete output |
| ANB10D | Node Interface Unit | FCS network interface |
| AIP827-32 | Analog Input Module | Redundant high-performance module |
| AMM22 S3 | Analog Multiplexer Module | 16-channel analog multiplexer |
| AIP504-51 | Net Coupler Module | Ethernet network interface |
| ANT411-50 | ESB Bus Repeater Module | Extends ESB communication range |
| Company Information | ||||||||
| [email protected] | ||||||||
| Mobile | +8613666033393 | |||||||
| +8613666033393 | ||||||||
| 13666033393 | ||||||||
| Add | Room 1004, No. 62 Xiangxiu Li, Siming District, Xiamen City, Fujian Province, China | |||||||
Excellent PLC Co., Ltd. has a large number of brand new and original PLC and DCS spare parts, with more than 60 cooperative countries. All products are guaranteed for 1 year and delivered to you by high-quality express. We are committed to using the best products and the most favorable prices to meet the needs and friendship of our customers. We have won the trust of thousands of customers, including these excellent customers.
As for the delivery time, when we receive your order requirements, we will arrange for warehouse personnel to test and verify the products. After you place the order, we will send it to you within 24 hours.
Excellent PLC
