Product Introduction
The HIMA F3316 is a Safety Systems Input Module designed specifically for high-integrity safety applications in process industries. Manufactured by HIMA, a global leader in safety automation solutions, this module forms a critical part of a fail-safe control system used to monitor field input signals such as contact closures, switches, or digital sensor outputs.
The F3316 ensures reliable detection and transmission of digital inputs to the safety controller under all operating conditions. It is engineered with rigorous attention to signal integrity, fault detection, and system diagnostics, making it suitable for Safety Integrity Level (SIL) 3 systems as defined by IEC 61508.
Its robust design, paired with seamless integration into the HIMA HIMax and HIQuad platforms, enables the F3316 to deliver secure, redundant, and error-checked communication for critical operations where failure is not an option.
Product Specifications
Parameter | Details |
---|---|
Model | F3316 |
Product Type | Safety Input Module |
Manufacturer | HIMA |
Input Channels | 16 Digital Inputs |
Input Type | Potential-free contacts or electronic sensors |
Input Voltage Range | 18–30 VDC (typically 24 VDC) |
Channel Monitoring | Yes (short circuit, wire break detection) |
Response Time | Typically < 10 ms |
Power Supply | Via backplane bus |
Interface | System Bus |
Status Indicators | LED for each channel + system status |
Operating Temperature | -20°C to +60°C |
Storage Temperature | -40°C to +85°C |
Humidity Range | 5% to 95% non-condensing |
Mounting Type | DIN rail mounting |
Protection Class | IP20 (housing) |
Certification | SIL3 (IEC 61508), ATEX, CE |
Dimensions (W×H×D) | 200 × 100 × 25 mm |
Weight | 0.3 kg |
Product Applications
The HIMA F3316 is widely used in industrial sectors where reliable monitoring of input signals is essential for operational safety. Typical application areas include:
-
Emergency Shutdown Systems (ESD): Detects critical conditions requiring plant shutdown.
-
Fire & Gas Detection Systems (FGS): Interfaces with flame detectors, smoke sensors, and gas analyzers.
-
Burner Management Systems (BMS): Monitors burner safety interlocks.
-
Turbomachinery Control: Ensures safe operation of turbines through contact and speed monitoring.
-
Power Generation: Interfaces with switchgear and field interlocks.
-
Chemical & Petrochemical: Connects sensors and field devices in explosive and high-risk zones.
Product Advantages
-
High Channel Density: 16 isolated digital inputs in a compact form factor reduce panel space requirements.
-
System Diagnostics: Each input channel is monitored for faults such as open wires or short circuits.
-
Designed for SIL3: Compliant with functional safety standards, ensuring safe operation in critical environments.
-
Seamless Integration: Compatible with HIMax and HIQuad safety systems, allowing scalable configurations.
-
LED Indicators: Real-time channel status indicators simplify troubleshooting and maintenance.
-
Long-Term Reliability: Industrial-grade components ensure durability under harsh operating conditions.
-
Maintenance Friendly: Hot-swappable design (in supported platforms) minimizes system downtime.
Frequently Asked Questions (FAQ)
-
What is the primary function of the HIMA F3316 module?
It monitors 16 digital inputs from field devices and transmits them to a safety controller for logic processing. -
Is the F3316 certified for use in SIL3 safety systems?
Yes, it is fully certified for SIL3 applications under IEC 61508. -
What type of signals can the F3316 process?
It supports potential-free contact closures or active low-voltage transistor outputs. -
How are input faults detected?
Each input is individually monitored for wire break, short circuit, or invalid signal levels. -
Can this module be used in explosive environments?
Yes, when integrated with appropriate barriers and certified enclosures, it is suitable for ATEX zones. -
Is the module hot-swappable?
In HIMax systems, it can be hot-swapped without shutting down the controller (depends on system configuration). -
Does the module have channel-specific LEDs?
Yes, each channel has an LED for status indication, making diagnostics easier. -
What are the dimensions and weight of the F3316?
It measures 200 × 100 × 25 mm and weighs 0.3 kg. -
How is the F3316 installed?
It is mounted on a DIN rail and communicates via the system backplane bus. -
Is it compatible with older HIMA platforms?
It is designed for newer HIMA systems like HIMax, but compatibility depends on the overall configuration.
Recommended Related Models (Same Series or Function)
Model Number | Description | Input Type | Channels | Dimensions (mm) |
---|---|---|---|---|
F3315 | Dual-channel switching amplifier | Relay | 2 | 35 × 160 × 120 |
F3320 | Digital input module with diagnostics | Contact/Sensor | 16 | 35 × 160 × 120 |
F3221 | Digital input module for HIQuad | 24 VDC | 16 | 130 × 120 × 35 |
F3420 | Analog input module | 4-20 mA / 0-10 V | 8 | 35 × 160 × 120 |
F3513 | Relay output module | Relay | 4 | 35 × 160 × 120 |
F3113 | Time delay module | Contact | 1 | 35 × 160 × 120 |
Popular HIMA Modules (Same Brand)
Model Number | Description | Type | Dimensions (mm) | Application Area |
---|---|---|---|---|
F7133 | Analog output module | Analog Output | 35 × 160 × 120 | Process Control |
F8650X | Safety System CPU Module | CPU | 60 × 210 × 160 | Central Processing |
F7553 | Digital output module | Digital Output | 35 × 160 × 120 | Machine Control |
F8640 | Power supply unit | Power Supply | 50 × 210 × 160 | Safety System Power Management |
F8621A | Communication module for redundant networks | Network Interface | 35 × 160 × 120 | Data Communication |
F6705 | Redundancy switching unit | Redundancy Control | 35 × 160 × 120 | High Availability Systems |