Product Introduction
The Yokogawa ALR111-S00 is a serial communication module engineered to facilitate high-speed and reliable serial data exchange between Yokogawa’s process control systems and external devices. Designed for seamless integration within the CENTUM VP and STARDOM automation platforms, the ALR111-S00 ensures efficient communication using serial protocols such as RS-232C and RS-422A/RS-485. It plays a crucial role in connecting PLCs, sensors, actuators, barcode readers, and other field devices to Yokogawa’s control environment.
This module is typically mounted within a system rack and acts as a bridge between different layers of the industrial communication hierarchy, ensuring data integrity and process optimization in real-time. With robust construction, long operational life, and compliance with industrial standards, the ALR111-S00 is well-suited for mission-critical applications in process industries such as oil and gas, chemicals, power, and water treatment.
Product Specifications
| Parameter | Description | 
|---|---|
| Model Number | ALR111-S00 | 
| Manufacturer | Yokogawa Electric Corporation | 
| Product Type | Serial Communication Module | 
| Communication Interface | RS-232C / RS-422A / RS-485 selectable | 
| Baud Rate Support | 1,200 to 115,200 bps | 
| Data Format | Start bit, data bits (7/8), parity (odd/even/none), stop bit | 
| Isolation | Optical isolation between communication and system circuits | 
| Error Handling | Parity check, framing error detection | 
| Status Indicators | LED for TX/RX, error, and module health | 
| Power Consumption | Approx. 2.5 W | 
| Operating Temperature | 0 to 50°C | 
| Storage Temperature | -20 to 70°C | 
| Humidity Range | 5% to 95% RH (non-condensing) | 
| Mounting Method | Mounted on a baseplate or I/O unit chassis | 
| Dimensions (W×H×D) | 126.7 × 32.8 × 130 mm | 
| Weight | 0.3 kg | 
| Compliance | CE, UL, CSA, RoHS | 
| Software Support | Configurable via Yokogawa system configuration tools | 
Product Applications
The ALR111-S00 module is utilized across various industrial control applications requiring serial data communication. Key applications include:
- 
PLC-to-DCS Communication: Connecting third-party PLCs with Yokogawa DCS. 
- 
Instrument Data Acquisition: Receiving data from serial instruments like analyzers and sensors. 
- 
Barcode/RFID Integration: Interfacing with scanners for traceability in production lines. 
- 
Remote Terminal Units (RTUs): Enabling communication with RTUs for remote data access. 
- 
Legacy System Integration: Connecting older equipment with serial-only ports into modern control systems. 
- 
Building Management Systems (BMS): Communicating with HVAC controllers or access systems. 
Product Advantages
- 
Multi-Protocol Support: Offers flexible RS-232C and RS-485/422 interfaces. 
- 
Robust Communication: Ensures stable data transfer even in noisy industrial environments. 
- 
Flexible Configuration: Baud rates, parity, and data formats are easily adjustable. 
- 
Compact Design: Small footprint allows for efficient cabinet space usage. 
- 
Diagnostic LEDs: Real-time communication status and fault indication for easier troubleshooting. 
- 
High Compatibility: Seamless integration with Yokogawa’s automation platforms and third-party systems. 
- 
Long-Term Reliability: Industrial-grade components for continuous 24/7 operation. 
- 
Cost-Efficiency: Enables modernization of legacy equipment without complete overhaul. 
Frequently Asked Questions (FAQ)
- 
What communication protocols does the ALR111-S00 support? 
 The ALR111-S00 supports RS-232C, RS-422A, and RS-485 serial communication standards.
- 
Is the ALR111-S00 compatible with CENTUM VP? 
 Yes, it is fully compatible and configurable through Yokogawa’s system engineering tools.
- 
How is the module powered? 
 It receives power through the system rack it is mounted in, with a typical consumption of 2.5 W.
- 
Can I use this module in outdoor environments? 
 The module is designed for indoor use within a control cabinet. Use in outdoor settings requires proper enclosure.
- 
How do I configure the baud rate and data format? 
 Configuration is done via Yokogawa’s engineering workstation or configuration tools.
- 
Is there galvanic isolation in the communication path? 
 Yes, optical isolation is provided between system circuitry and serial ports for safety.
- 
What are the indicators on the module? 
 The LEDs indicate transmit (TX), receive (RX), error, and module health status.
- 
Can I use this module to communicate with Modbus RTU devices? 
 Yes, provided the proper protocol support is configured, it can handle Modbus RTU over serial.
- 
What is the lifespan of the module? 
 Under normal industrial conditions, the lifespan exceeds 10 years.
- 
What certifications does the ALR111-S00 hold? 
 It is CE marked and complies with UL, CSA, and RoHS standards.
Related Models from the Same Series
| Model | Description | Key Features | 
|---|---|---|
| ALR121-S00 | Enhanced serial module with dual-port configuration | RS-485/RS-422 dual channel | 
| ALR110-S00 | Basic RS-232C communication module | Ideal for legacy connections | 
| ALP121-S00 | Protocol conversion and serial data handling | Multi-device connectivity | 
| ALR113-S00 | Isolated RS-485 communication module | Strong electrical noise immunity | 
| ALR124-S00 | High-speed RS-422 communication interface | Optimized for fast polling systems | 
| ALP122-P12 | Advanced protocol gateway module | Interconnects various serial protocols | 
Popular Yokogawa Models
| Model | Description | Key Features | 
|---|---|---|
| YFGW410 | Wireless gateway for field device networks | ISA100 wireless support | 
| CENTUM VP | Distributed control system (DCS) platform | Highly scalable, secure, and reliable | 
| ProSafe-RS | Safety instrumented system with SIL-3 certification | Integrated with DCS | 
| YHC5150X | Handheld HART communicator | Portable, rugged design | 
| YTA610 | Smart temperature transmitter | Dual input, HART protocol | 
| FCN-RTU | Compact remote terminal unit for field sites | Ideal for oil & gas and utilities | 
 Excellent PLC