Product Overview
The Yokogawa SAI143-H03 is a 16-channel analog input module engineered for use within the ProSafe-RS safety control system. Specially designed to accept 4 to 20 mA current inputs from field instrumentation, it integrates HART communication, enabling simultaneous process signal acquisition and device diagnostics. The module is robustly isolated and ideal for high-reliability and safety-critical applications in process automation environments like oil & gas, power generation, and chemical plants.
Technical Specifications
| Parameter | Specification |
|---|---|
| Model | SAI143-H03 |
| Input Channels | 16 channels (individually isolated per module) |
| Input Type | Current input (4 to 20 mA) |
| Permissible Input Range | 0 to 25 mA |
| Input Impedance (Power ON) | 250 Ω + voltage drop in input protection circuit (0.45 V max drop) |
| Input Impedance (Power OFF) | ≥ 500 kΩ |
| Rated Accuracy | ±16 µA (0.05 to 23 mA, style code S3 or later) |
| Data Update Frequency | 40 ms |
| Temperature Drift | ±16 µA/10°C |
| Withstand Voltage | 1.5 kV AC (Input signal to system, 1 min) |
| Transmitter Power Supply | 16.15 V min at 20 mA, 26.4 V max at 0 mA (max current 25 mA) |
| Power Supply Channels | 2-wire or 4-wire, channel-by-channel selectable |
| Power Consumption (5V) | 320 mA |
| Power Consumption (24V) | 550 mA |
| External Connections | Pressure clamp terminal / MIL cable / Dedicated signal cable |
| HART Communication | Supported (One modem per module; one device at a time) |
| Weight | 0.34 kg |
| Dimensions (W x H x D) | 130 x 107.5 x 32.8 mm |
Applications
-
Industrial process control in oil & gas, petrochemical, and chemical industries
-
Safety instrumentation systems within emergency shutdown applications
-
Power generation plants (thermal, nuclear, hydro)
-
High-availability input collection for DCS and SIS environments
-
Monitoring and diagnostic communication with HART-enabled transmitters
Key Advantages
-
High Accuracy: Maintains tight measurement tolerances even in the low current range down to 0.05 mA
-
Full HART Compatibility: Supports device diagnostics and configuration through PRM integration
-
Isolation & Safety: 1.5 kV isolation between system and input channels ensures operational safety
-
Dual-Redundancy Capable: Enhances system availability by allowing redundant configurations
-
Fast Response: 40 ms update time ensures real-time process visibility
-
Flexible Wiring Options: Compatible with both 2-wire and 4-wire transmitter configurations
-
Compact Form Factor: Space-efficient installation in control cabinets
-
Surge Protection & False Insertion Options: Configurable for enhanced safety and field robustness
Frequently Asked Questions (FAQ)
Q1: What signal types does the SAI143-H03 accept?
A1: It accepts analog current inputs ranging from 4 to 20 mA, with an extended permissible range of 0 to 25 mA.
Q2: Can this module be used in hazardous environments?
A2: Yes, explosion-protected versions are available via specific suffix codes (e.g., “E” or “F”).
Q3: Does it support HART communication?
A3: Yes, the H03 variant integrates HART communication compliant with HART Protocol Revision 5.7.
Q4: How many HART devices can be connected to the module?
A4: One HART device can be connected per input channel, but communication occurs with one device at a time due to a single modem.
Q5: What is the input update rate?
A5: The data update frequency is 40 milliseconds.
Q6: Is the module isolated?
A6: Yes, the entire module is galvanically isolated from the system and other channels.
Q7: What are the installation options for the terminal connections?
A7: It supports pressure clamp terminals, MIL cable, or dedicated signal cables, with various suffix and option codes.
Q8: What is the operating temperature range?
A8: When equipped with the appropriate suffix (e.g., “3” or “C”), the module supports operation from -20°C to +70°C.
Q9: Can I use it in a dual-redundant configuration?
A9: Yes, dual redundancy is supported for enhanced reliability.
Q10: What kind of diagnostic capabilities does HART communication enable?
A10: It enables device-level diagnostics, configuration, and partial stroke testing (when applicable), viewable via Yokogawa’s PRM system.
Recommended Related or Series Models
| Model | Description | Input Type | Channels | HART | Weight | Dimensions (mm) |
|---|---|---|---|---|---|---|
| SAI143-S03 | Analog Input Module (no HART) | 4–20 mA | 16 | No | 0.34 kg | 130 x 107.5 x 32.8 |
| SAV144-H03 | Analog Voltage Input Module with HART | 1–5 V / 1–10 V | 16 | Yes | 0.24 kg | 130 x 107.5 x 32.8 |
| SAT145-S06 | TC/mV Input Module | Thermocouple/mV | 16 | No | 0.47 kg | 130 x 107.5 x 32.8 |
| SAR145-S06 | RTD Input Module | RTD (Pt100, Ni100) | 16 | No | 0.47 kg | 130 x 107.5 x 32.8 |
| SAI533-H06 | Analog Output Module with HART | 4–20 mA | 8 | Yes | 0.26 kg | 130 x 107.5 x 32.8 |
| SAI533-S06 | Analog Output Module (Standard, no HART) | 4–20 mA | 8 | No | 0.26 kg | 130 x 107.5 x 32.8 |
Recommended Popular Yokogawa Modules
| Model | Description | Type | Channels | HART | Weight | Dimensions (mm) |
|---|---|---|---|---|---|---|
| SAI143-H03 | Analog Input Module with HART | 4–20 mA | 16 | Yes | 0.34 kg | 130 x 107.5 x 32.8 |
| SAI533-H06 | Analog Output Module with HART | 4–20 mA | 8 | Yes | 0.26 kg | 130 x 107.5 x 32.8 |
| AAI143-H50 | FOUNDATION Fieldbus AI Module | Fieldbus (FF) | 16 | Yes | ~0.3 kg | Similar size |
| AAI543-H00 | FOUNDATION Fieldbus AO Module | Fieldbus (FF) | 8 | Yes | ~0.3 kg | Similar size |
| ADV551-P00 | Digital Input Module for CENTUM VP | DI | 16 | N/A | 0.27 kg | ~120 x 100 x 35 |
| AAR181-S00 | Sequence of Events (SOE) Input Module | SOE | 16 | N/A | 0.28 kg | ~130 x 107.5 x 32.8 |
Frequently Asked Questions (FAQ)
Q1: What signal types does the SAI143-H03 accept?
A1: It accepts analog current inputs ranging from 4 to 20 mA, with an extended permissible range of 0 to 25 mA.
Q2: Can this module be used in hazardous environments?
A2: Yes, explosion-protected versions are available via specific suffix codes (e.g., “E” or “F”).
Q3: Does it support HART communication?
A3: Yes, the H03 variant integrates HART communication compliant with HART Protocol Revision 5.7.
Q4: How many HART devices can be connected to the module?
A4: One HART device can be connected per input channel, but communication occurs with one device at a time due to a single modem.
Q5: What is the input update rate?
A5: The data update frequency is 40 milliseconds.
Q6: Is the module isolated?
A6: Yes, the entire module is galvanically isolated from the system and other channels.
Q7: What are the installation options for the terminal connections?
A7: It supports pressure clamp terminals, MIL cable, or dedicated signal cables, with various suffix and option codes.
Q8: What is the operating temperature range?
A8: When equipped with the appropriate suffix (e.g., “3” or “C”), the module supports operation from -20°C to +70°C.
Q9: Can I use it in a dual-redundant configuration?
A9: Yes, dual redundancy is supported for enhanced reliability.
Q10: What kind of diagnostic capabilities does HART communication enable?
A10: It enables device-level diagnostics, configuration, and partial stroke testing (when applicable), viewable via Yokogawa’s PRM system.
Recommended Related or Series Models
| Model | Description | Input Type | Channels | HART | Weight | Dimensions (mm) |
|---|---|---|---|---|---|---|
| SAI143-S03 | Analog Input Module (no HART) | 4–20 mA | 16 | No | 0.34 kg | 130 x 107.5 x 32.8 |
| SAV144-H03 | Analog Voltage Input Module with HART | 1–5 V / 1–10 V | 16 | Yes | 0.24 kg | 130 x 107.5 x 32.8 |
| SAT145-S06 | TC/mV Input Module | Thermocouple/mV | 16 | No | 0.47 kg | 130 x 107.5 x 32.8 |
| SAR145-S06 | RTD Input Module | RTD (Pt100, Ni100) | 16 | No | 0.47 kg | 130 x 107.5 x 32.8 |
| SAI533-H06 | Analog Output Module with HART | 4–20 mA | 8 | Yes | 0.26 kg | 130 x 107.5 x 32.8 |
| SAI533-S06 | Analog Output Module (Standard, no HART) | 4–20 mA | 8 | No | 0.26 kg | 130 x 107.5 x 32.8 |
Recommended Popular Yokogawa Modules
| Model | Description | Type | Channels | HART | Weight | Dimensions (mm) |
|---|---|---|---|---|---|---|
| SAI143-H03 | Analog Input Module with HART | 4–20 mA | 16 | Yes | 0.34 kg | 130 x 107.5 x 32.8 |
| SAI533-H06 | Analog Output Module with HART | 4–20 mA | 8 | Yes | 0.26 kg | 130 x 107.5 x 32.8 |
| AAI143-H50 | FOUNDATION Fieldbus AI Module | Fieldbus (FF) | 16 | Yes | ~0.3 kg | Similar size |
| AAI543-H00 | FOUNDATION Fieldbus AO Module | Fieldbus (FF) | 8 | Yes | ~0.3 kg | Similar size |
| ADV551-P00 | Digital Input Module for CENTUM VP | DI | 16 | N/A | 0.27 kg | ~120 x 100 x 35 |
| AAR181-S00 | Sequence of Events (SOE) Input Module | SOE | 16 | N/A | 0.28 kg | ~130 x 107.5 x 32.8 |
| Company Information | ||||||||
| [email protected] | ||||||||
| Mobile | +8613666033393 | |||||||
| +8613666033393 | ||||||||
| 13666033393 | ||||||||
| Add | Room 1004, No. 62 Xiangxiu Li, Siming District, Xiamen City, Fujian Province, China | |||||||
Excellent PLC Co., Ltd. has a large number of brand new and original PLC and DCS spare parts, with more than 60 cooperative countries. All products are guaranteed for 1 year and delivered to you by high-quality express. We are committed to using the best products and the most favorable prices to meet the needs and friendship of our customers. We have won the trust of thousands of customers, including these excellent customers.
As for the delivery time, when we receive your order requirements, we will arrange for warehouse personnel to test and verify the products. After you place the order, we will send it to you within 24 hours.
Excellent PLC