Product Introduction:
The Triconex 9662-110 3000570-310 DO Terminal Panel is a dedicated output interface module designed to facilitate the connection of discrete digital output signals from the Triconex safety systems to field devices. This terminal panel plays a vital role in ensuring the safe and reliable transmission of control signals to actuators, valves, and other output equipment in industrial safety systems.
Engineered for use in high-integrity safety environments, the 9662-110 terminal panel offers robust mechanical design and secure wiring termination points, making it a trusted component in complex safety instrumented systems (SIS). Its compatibility with Triconex controllers and its ease of installation make it a valuable asset for process control and safety automation professionals.
Product Specifications:
Parameter | Details |
---|---|
Model Number | 9662-110 |
Manufacturer | Triconex (Emerson) |
Product Type | Digital Output (DO) Terminal Panel |
Number of Channels | 16 discrete digital output channels |
Terminal Type | Screw clamp terminals with secure locking |
Signal Type | Discrete digital output signals |
Output Voltage | Up to 30 V DC |
Output Current | Up to 0.5 A per channel |
Insulation Resistance | > 10^9 Ohms |
Dielectric Strength | 2.5 kV AC for 1 minute |
Operating Temperature Range | -20°C to +70°C |
Storage Temperature Range | -40°C to +85°C |
Humidity | 5% to 95% non-condensing |
Mounting | DIN rail or panel mounting |
Dimensions (L × W × H) | 114.3 × 196.85 × 107.95 mm |
Weight | 0.5 kg |
Material | Flame-retardant plastic housing, corrosion-resistant metal terminals |
Certifications | SIL 3 certified, CE, UL recognized |
Product Applications:
-
Safety Instrumented Systems: Provides the interface for safe output signals to valves, alarms, and actuators in critical safety applications.
-
Process Automation: Controls outputs for emergency shutdown, process control valves, and motor starters in petrochemical, chemical, and power plants.
-
Fire & Gas Systems: Sends discrete output commands for fire suppression systems and gas detection alarms.
-
Industrial Machinery: Used to drive safety-rated output devices in manufacturing and automation systems.
-
Power Generation: Controls turbine trip outputs and other safety-related shutdown functions.
-
Emergency Shutdown Systems (ESD): Acts as the reliable digital output interface for emergency stop and shutdown commands.
Product Advantages:
-
Robust and Reliable: Designed to maintain secure and stable output connections even in harsh industrial environments with vibration and temperature variations.
-
High Safety Integrity: Certified to SIL 3 standards, making it suitable for the most stringent safety applications.
-
Easy Installation: Features screw clamp terminals that simplify wiring and maintenance tasks.
-
Compact Form Factor: Allows for efficient use of cabinet space without compromising accessibility.
-
Durable Materials: Constructed with flame-retardant plastics and corrosion-resistant metals for longevity and safety compliance.
-
Versatile Mounting: Supports both DIN rail and panel mounting options for flexible integration.
-
Clear Labeling: Terminal points are clearly marked, facilitating accurate wiring and troubleshooting.
-
Diagnostic Friendly: Centralizes output wiring for easier system diagnostics and fault isolation.
-
Industry Proven: Backed by Emerson’s trusted Triconex brand, known for safety and reliability in critical applications.
Frequently Asked Questions (FAQ):
-
What is the purpose of the 9662-110 DO Terminal Panel?
It serves as the termination point for digital output signals from Triconex safety controllers to field devices such as valves and actuators. -
How many output channels does this panel support?
It supports up to 16 discrete digital output channels. -
What is the maximum voltage and current rating per output?
Each output can handle up to 30 V DC and 0.5 A. -
Is the terminal panel compatible with all Triconex safety controllers?
Yes, it is designed to work seamlessly with all Triconex controllers. -
What type of terminals are used for wiring?
The panel uses screw clamp terminals with secure locking to prevent loosening due to vibration. -
Can the panel be mounted on DIN rails?
Yes, it supports both DIN rail and panel mounting configurations. -
What certifications does this product have?
It is certified to meet SIL 3 standards and complies with CE and UL safety requirements. -
What are the operating temperature limits?
The panel operates reliably from -20°C to +70°C. -
How does the panel improve system diagnostics?
By centralizing output wiring, it simplifies fault detection and maintenance. -
Is this panel suitable for use in hazardous areas?
It is built for rugged industrial environments, but use in hazardous zones depends on the overall system certification and proper enclosures.
Related Models from the Same Series:
Model Number | Description | Channels | Mounting Type | Notes |
---|---|---|---|---|
9662-100 | 8-Channel Digital Output Terminal Panel | 8 | DIN rail | Smaller channel count option |
9662-110 | 16-Channel Digital Output Terminal Panel | 16 | DIN rail/panel | Standard full channel panel |
9662-120 | Digital Output Panel with Enhanced Labeling | 16 | Panel mount | Improved terminal identification |
9662-130 | Digital Output Terminal with Diagnostics | 16 | DIN rail | Diagnostic features included |
9662-140 | Compact Digital Output Terminal Panel | 8 | DIN rail | Smaller footprint design |
9662-150 | Digital Output Panel with Test Points | 16 | Panel mount | Supports in-circuit testing |
Popular Triconex Models (Same Brand):
Model Number | Description | Type | Application | Certification |
---|---|---|---|---|
3002 | Safety Logic Solver Controller | Controller | Core safety logic processing | SIL 3 |
3620 | 32-Channel Digital Input Module | I/O Module | Digital input acquisition | SIL 3 |
3621 | 16-Channel Digital Output Module | I/O Module | Digital output control | SIL 3 |
9562 | Terminal Panel Module | Terminal Module | Field wiring interface | SIL 3 |
3742 | Power Supply Module | Power Supply | Power distribution and backup | SIL 3 |
3502 | TriStation Safety System Software | Software | System configuration and diagnostics | SIL 3 |