The Honeywell 10302/1/1 Watchdog Repeater Module is a critical monitoring and safety assurance component designed for Honeywell’s automation and safety systems. This module functions as a watchdog timer and signal repeater, ensuring continuous signal integrity and fail-safe operation within industrial process control systems. It actively monitors the health and responsiveness of critical system functions and can initiate a fail-safe state if abnormal behavior is detected.
Ideal for use in Safety Instrumented Systems (SIS) and Emergency Shutdown Systems (ESD), this module provides redundancy and error checking by repeating control signals and verifying continuous operation. Any detected malfunction triggers automatic protective actions, ensuring system availability and safety.
Product Specifications
Parameter | Description |
---|---|
Model | 10302/1/1 |
Manufacturer | Honeywell |
Type | Watchdog Repeater Module |
Primary Function | Signal health monitoring and automatic fallback |
Channels Supported | 1 channel |
Input Type | Digital pulse or heartbeat signal |
Output Type | Repeated signal output (fail-safe in error state) |
Signal Delay | < 10 ms typical |
Operating Voltage | Supplied via system backplane |
Operating Temperature | 0°C to 60°C (32°F to 140°F) |
Storage Temperature | -40°C to 85°C (-40°F to 185°F) |
Humidity Range | 5% to 95% RH non-condensing |
Diagnostics | Built-in self-check and LED status indication |
Mounting Method | DIN rail or panel mount |
Certifications | CE, UL, CSA, SIL-rated (application-dependent) |
Dimensions (W×H×D) | 160 x 100 x 25 mm |
Weight | 0.12 kg |
Product Applications
-
Safety Instrumented Systems (SIS): Monitors the pulse or heartbeat signals from safety logic solvers to verify system responsiveness.
-
Emergency Shutdown Systems (ESD): Detects failure conditions and triggers safe shutdown protocols.
-
Redundant Control Architectures: Repeats and verifies system commands in multi-path control networks.
-
Power Plants: Ensures safe and consistent operation of automated shutdown mechanisms.
-
Oil & Gas Facilities: Used to ensure signal reliability and safety compliance in hazardous locations.
-
Chemical and Petrochemical Plants: Protects against silent system faults by monitoring signal integrity.
Product Advantages
-
Reliable Fault Detection: Continuously checks for signal dropouts or abnormal timing to maintain process integrity.
-
Fail-Safe Action: Automatically transfers system into a known safe state in the event of a fault or watchdog timeout.
-
Signal Repeating Functionality: Ensures signals are transmitted with integrity even over long distances or in complex systems.
-
Integrated Diagnostics: LED indicators provide at-a-glance status to reduce troubleshooting time.
-
Compact Modular Design: Easily fits within existing panel infrastructure with minimal space requirements.
-
Industry Certifications: Meets international safety standards (UL, CE, CSA) and can support SIL-rated systems.
Frequently Asked Questions (FAQ)
-
What is the purpose of the 10302/1/1 Watchdog Repeater Module?
It monitors a digital heartbeat or control signal and ensures continuous communication; if the signal fails, it initiates a fail-safe response. -
Can this module be used in SIL-rated systems?
Yes, when configured within approved Honeywell architectures, it supports use in SIL 2/3 environments. -
What kind of signals does it monitor?
It typically monitors digital pulse signals or heartbeat signals from controllers or safety logic solvers. -
What happens if a signal is lost or malformed?
The module will activate a fail-safe state or output a defined alarm response to indicate a system fault. -
Does the module offer diagnostic feedback?
Yes, it includes LED indicators for power status and signal activity, as well as internal self-checking logic. -
Is it compatible with Honeywell’s Safety Manager system?
Absolutely. It is often used alongside Honeywell Safety Manager, TDC 3000, and Experion PKS platforms. -
Can it be mounted horizontally and vertically?
Yes, its flexible DIN rail or panel mount allows both mounting orientations. -
What is the response time of the module?
The internal signal processing delay is typically under 10 milliseconds. -
Is there any configuration or firmware needed?
The module comes pre-configured for standard operation, but may require DCS system integration. -
How often does the module require maintenance?
It is designed for long-term, low-maintenance use. Visual inspection and periodic loop checks are recommended.
Related Models from the Same Series or Function Group
Model | Description | Function | Dimensions (mm) | Weight |
---|---|---|---|---|
10302/1/2 | Dual-channel Watchdog Repeater Module | Watchdog & Repeater | 125×130×35 | 370 g |
10303/1/1 | Heartbeat Monitor Module | Signal Monitoring | 125×130×35 | 360 g |
10304/1/1 | Relay Driver Module | Output Actuation | 125×130×35 | 340 g |
10208/2/1 | Relay Output Module | Relay Output | 125×130×35 | 350 g |
10209/2/1 | Digital Input Module | Digital Input | 125×130×35 | 330 g |
10213/2/1 | Mixed I/O Module | Input/Output (Mixed) | 125×130×35 | 355 g |
Popular Honeywell Models (Same Brand)
Model | Description | Function | Dimensions (mm) | Weight |
---|---|---|---|---|
CC-TAOX01 | Analog Output Module | Analog Output | 120×125×35 | 320 g |
CC-PDOB01 | Digital Output Module for C300 Controller | Digital Output | 120×125×35 | 300 g |
CC-TDIL01 | Digital Input Module | Digital Input | 120×125×35 | 310 g |
MC-TAMR03 | Analog Input Module | Analog Input | 126×134×36 | 370 g |
FC-TPSU-2430 | Redundant Power Supply Unit | Power Supply | 125×130×45 | 800 g |
CC-PCNT01 | Pulse Counter Module | Pulse Input | 125×130×35 | 310 g |