Add Room 1004, No. 62 Xiangxiu Li, Siming District, Xiamen City, Fujian Province, China

Product Introduction

The Honeywell 2MLF-RD8A RTD Input Module is a high-performance input device designed specifically for reading temperature signals from Resistance Temperature Detectors (RTDs). This module is an integral part of Honeywell’s industrial automation systems, including programmable logic controllers (PLCs) and distributed control systems (DCS). It supports multiple RTD types and delivers high-accuracy measurements critical for temperature-sensitive applications in manufacturing, power generation, oil and gas, and process industries.

Built with robust industrial-grade components, the 2MLF-RD8A ensures long-term reliability in harsh environments. It provides eight channels of RTD input, supporting both 2-wire and 3-wire configurations. This module enhances process visibility and enables tighter control over thermal processes, making it an indispensable component in modern industrial automation systems.


Product Specifications

Parameter Description
Product Name RTD Input Module
Model Number 2MLF-RD8A
Manufacturer Honeywell
Input Type RTD (Resistance Temperature Detector)
Supported RTD Types Pt100, Pt1000, Ni100, Cu50, Cu100
Number of Channels 8
Measurement Configuration 2-wire and 3-wire
Resolution 16-bit ADC resolution
Accuracy ±0.1% of span
Input Range -200°C to +850°C (depends on RTD type)
Isolation Channel-to-bus and channel-to-channel isolation
Update Rate 10 ms per channel
Diagnostic Capabilities Open wire detection, short circuit detection
Operating Temperature Range 0°C to 60°C
Storage Temperature Range -40°C to +85°C
Humidity Range 5% to 95% non-condensing
Power Supply Voltage 24V DC nominal
Power Consumption < 3W
Dimensions 245 x 87 x 68 mm
Weight 0.34 kg
Mounting DIN rail or panel mount
Communication Interface Backplane bus or remote I/O rack
Certifications CE, RoHS, UL/CSA

Product Applications

  • Temperature Monitoring in Process Plants: Ideal for monitoring temperatures in reactors, heat exchangers, and furnaces.

  • HVAC and Building Automation: Used to ensure proper temperature control in ventilation and climate systems.

  • Food & Beverage Industry: Maintains process temperatures during cooking, fermentation, and cooling.

  • Pharmaceutical Manufacturing: Precise temperature control for cleanrooms and chemical reactions.

  • Power Generation Facilities: Critical for monitoring boiler temperatures, turbine bearings, and transformers.

  • Oil & Gas Sector: Suitable for onshore/offshore operations requiring rugged and accurate temperature input modules.


Product Advantages

  • Multi-Type RTD Support: Compatible with a wide range of RTDs for flexible deployment.

  • High Accuracy & Resolution: Ensures precision monitoring with minimal error margin.

  • Eight Isolated Channels: Enables simultaneous temperature sensing from multiple points.

  • Built-in Diagnostics: Features open wire and short circuit detection to reduce downtime.

  • Rugged Design: Withstands harsh industrial environments with shock and vibration resistance.

  • Flexible Installation: Compact size with DIN/panel mounting support for various enclosures.

  • Low Power Consumption: Efficient operation with minimal heat generation.

  • Seamless Integration: Easily integrates with Honeywell’s PLC, DCS, and SCADA systems.

  • Fast Sampling Rate: Enables real-time temperature monitoring with 10ms update rate.

  • Long-Term Reliability: Engineered for continuous operation in mission-critical environments.


Frequently Asked Questions (FAQ)

  1. What RTD types does the Honeywell 2MLF-RD8A support?
    It supports Pt100, Pt1000, Ni100, Cu50, and Cu100 RTDs.

  2. How many channels does this module have?
    It has 8 independent, isolated RTD input channels.

  3. What kind of configurations are supported — 2-wire or 3-wire?
    Both 2-wire and 3-wire configurations are supported.

  4. Can I use this module with non-Honeywell systems?
    It is optimized for Honeywell systems but may integrate with third-party platforms if electrical specifications are met.

  5. Does the module provide diagnostic features?
    Yes, it includes open-wire and short-circuit detection for each channel.

  6. What is the input range for temperature?
    It typically supports -200°C to +850°C, depending on the RTD type.

  7. Is the module hot-swappable?
    This depends on the rack system used. Some Honeywell systems support hot-swap features.

  8. What kind of mounting is required?
    The module can be mounted on DIN rails or directly to panels.

  9. How is data communicated to the controller?
    Through the backplane or a remote I/O bus, depending on the system configuration.

  10. Is there isolation between the channels?
    Yes, it features both channel-to-channel and channel-to-bus isolation for safety and noise immunity.


Related Models (Same Series or Function)

Model Description Channels Input Type Key Feature
2MLF-TC8A Thermocouple Input Module 8 TC High-precision thermocouple input
2MLF-AI8A Analog Input Module 8 Voltage/Current General-purpose analog input
2MLF-AO4A Analog Output Module 4 Voltage/Current For analog control output
2MLF-DO16A Digital Output Module 16 Discrete Relay or transistor output
2MLF-DI16A Digital Input Module 16 Discrete High-speed digital input
2MLF-RTD4A RTD Input Module (Compact) 4 RTD Compact version for small systems

Popular Honeywell Models (Different Functions, Same Brand)

Model Function Application Key Feature
C300 Controller Process Controller DCS Automation Advanced control and logic processing
51454416-100 Analog Input Module Experion PKS Systems 8-channel analog signal acquisition
51204172-175 RTD/TC Input Module Temperature sensing Dual-input support with diagnostics
51199929-100 Digital Output Module Control systems Isolated digital output
51400997-100 Power Supply Module System power distribution Hot-swappable, redundant-capable
HC900-CPU-202 Hybrid Controller Unit Hybrid automation Combines logic, PID, and sequencing

Frequently Asked Questions (FAQ)

  1. What RTD types does the Honeywell 2MLF-RD8A support?
    It supports Pt100, Pt1000, Ni100, Cu50, and Cu100 RTDs.

  2. How many channels does this module have?
    It has 8 independent, isolated RTD input channels.

  3. What kind of configurations are supported — 2-wire or 3-wire?
    Both 2-wire and 3-wire configurations are supported.

  4. Can I use this module with non-Honeywell systems?
    It is optimized for Honeywell systems but may integrate with third-party platforms if electrical specifications are met.

  5. Does the module provide diagnostic features?
    Yes, it includes open-wire and short-circuit detection for each channel.

  6. What is the input range for temperature?
    It typically supports -200°C to +850°C, depending on the RTD type.

  7. Is the module hot-swappable?
    This depends on the rack system used. Some Honeywell systems support hot-swap features.

  8. What kind of mounting is required?
    The module can be mounted on DIN rails or directly to panels.

  9. How is data communicated to the controller?
    Through the backplane or a remote I/O bus, depending on the system configuration.

  10. Is there isolation between the channels?
    Yes, it features both channel-to-channel and channel-to-bus isolation for safety and noise immunity.

Related Models (Same Series or Function)

Model Description Channels Input Type Key Feature
2MLF-TC8A Thermocouple Input Module 8 TC High-precision thermocouple input
2MLF-AI8A Analog Input Module 8 Voltage/Current General-purpose analog input
2MLF-AO4A Analog Output Module 4 Voltage/Current For analog control output
2MLF-DO16A Digital Output Module 16 Discrete Relay or transistor output
2MLF-DI16A Digital Input Module 16 Discrete High-speed digital input
2MLF-RTD4A RTD Input Module (Compact) 4 RTD Compact version for small systems

Popular Honeywell Models (Different Functions, Same Brand)

Model Function Application Key Feature
C300 Controller Process Controller DCS Automation Advanced control and logic processing
51454416-100 Analog Input Module Experion PKS Systems 8-channel analog signal acquisition
51204172-175 RTD/TC Input Module Temperature sensing Dual-input support with diagnostics
51199929-100 Digital Output Module Control systems Isolated digital output
51400997-100 Power Supply Module System power distribution Hot-swappable, redundant-capable
HC900-CPU-202 Hybrid Controller Unit Hybrid automation Combines logic, PID, and sequencing

Honeywell 2MLF-RD8A RTD Input Module

Company Information
E-mail sales@xmjzjsgs.com
Mobile +8613666033393
Whatsapp +8613666033393
WeChat 13666033393
Add Room 1004, No. 62 Xiangxiu Li, Siming District, Xiamen City, Fujian Province, China

Excellent PLC Co., Ltd. has a large number of brand new and original PLC and DCS spare parts, with more than 60 cooperative countries. All products are guaranteed for 1 year and delivered to you by high-quality express. We are committed to using the best products and the most favorable prices to meet the needs and friendship of our customers. We have won the trust of thousands of customers, including these excellent customers.

As for the delivery time, when we receive your order requirements, we will arrange for warehouse personnel to test and verify the products. After you place the order, we will send it to you within 24 hours.

Prev:

Next:

Leave a message