Product Overview
The Honeywell FTA-T-14 is a Fail-Safe Digital Output Field Termination Assembly (FTA) engineered for use in safety-critical industrial control systems. Designed specifically for compatibility with Honeywell’s Safety Manager and FSC (Fail Safe Controller) platforms, this module enables safe, deterministic, and reliable actuation of field devices in response to logic-driven digital output commands.
The FTA-T-14 is structured to ensure fail-safe operation, meaning that outputs will default to a safe state in the event of a system failure or power loss. This feature is essential for applications in process safety systems, where the safe operation of actuators, relays, and control valves can protect both personnel and infrastructure.
Key Features
-
Fail-Safe Output Design: Ensures outputs revert to a safe state in case of failure
-
SIL 3 Certified: Fully compliant with IEC 61508 for use in safety instrumented systems
-
Direct Interface to Safety Manager: Enables accurate and secure output delivery to field devices
-
Field-Terminated Connections: Streamlines installation and maintenance
-
Redundancy Support: Ideal for deployment in redundant I/O architectures
-
LED Status Indicators: Provides quick visual feedback for diagnostics and operational status
-
Low Power Operation: Efficiently designed for low energy consumption while maintaining high performance
-
Compact DIN Rail Form Factor: Saves control cabinet space and simplifies layout
-
Industrial-Grade Protection: Built to withstand electrical and environmental stresses
Technical Specifications
Parameter | Specification |
---|---|
Model Number | FTA-T-14 |
Product Type | Fail-Safe Digital Output Field Termination Assembly |
Output Type | Digital fail-safe outputs |
Number of Outputs | 14 individual output channels |
Output Voltage | 24 VDC nominal |
Output Current | 2 A max per channel |
Fail-Safe Operation | Yes, with output fallback on failure |
SIL Rating | SIL 3 (certified to IEC 61508) |
System Compatibility | Honeywell Safety Manager, FSC |
Input Power Supply | 24 VDC (nominal), 18–30 VDC range |
Field Termination | Yes |
Protection Features | Short-circuit, overvoltage, reverse polarity |
Diagnostics | LED indicators for power, signal, and faults |
Mounting | 35 mm DIN rail (EN 60715 standard) |
Operating Temperature | -20°C to +60°C (-4°F to +140°F) |
Storage Temperature | -40°C to +85°C (-40°F to +185°F) |
Humidity Range | 5% to 95% RH, non-condensing |
Dimensions= | 145 × 70 × 65 mm |
Weight | 1.36 kg |
Certifications | CE, UL, RoHS, CSA, IEC 61508 |
Industry Applications
-
Oil & Gas: Critical actuation of blowdown valves, isolation switches, and fire suppression systems
-
Power Generation: Triggers safety interlocks, turbine trip devices, and shutdown logic
-
Chemical & Petrochemical: Ensures safe field device actuation during emergency situations
-
Pharmaceutical: Supports validated alarm and shutdown mechanisms in GxP-regulated environments
-
Water and Wastewater: Interfaces with emergency controls and overpressure valve systems
-
Mining and Metallurgy: Delivers safe output to control systems for high-risk equipment
Product Advantages
-
Safety First: Designed for fail-safe behavior, protecting people, equipment, and processes
-
Certified Performance: SIL 3 rating confirms suitability for high-integrity safety applications
-
Multi-Channel Output: Controls up to 14 devices from one compact module
-
Flexible Deployment: Easily integrated into new or existing Honeywell safety architectures
-
Built for Harsh Conditions: Robust enough for continuous use in rugged industrial environments
-
Minimal Downtime: LED diagnostics help pinpoint issues quickly, reducing troubleshooting time
-
Cost-Effective Safety: Combines multiple output channels in a single module, reducing system complexity
Frequently Asked Questions (FAQ)
-
Q: What makes the FTA-T-14 a “fail-safe” module?
A: It ensures that all outputs default to a safe (de-energized) state during failures or power loss. -
Q: How many output channels does the module provide?
A: The FTA-T-14 provides 14 discrete digital output channels. -
Q: Is the FTA-T-14 certified for safety applications?
A: Yes, it is SIL 3 certified under IEC 61508, suitable for safety instrumented systems. -
Q: Which Honeywell systems is it compatible with?
A: It is fully compatible with Honeywell Safety Manager and FSC systems. -
Q: What type of devices can be controlled using this module?
A: It can control relays, solenoids, actuators, alarms, and other 24 VDC-driven field devices. -
Q: What protection features does it have?
A: It includes short-circuit, reverse polarity, and overvoltage protection. -
Q: What is the typical power supply for this module?
A: It operates on 24 VDC, with a functional range from 18–30 VDC. -
Q: Can it be used in redundant configurations?
A: Yes, it is designed for use in redundant I/O systems for increased reliability. -
Q: Are status indicators available?
A: Yes, LED indicators provide visual feedback on power, activity, and fault status. -
Q: What environments is the module rated for?
A: It operates in industrial environments with temperatures from -20°C to +60°C, and up to 95% humidity.
Related or Similar Honeywell Models
Model Number | Description |
---|---|
FS-TSRO-0824 | 8-channel Digital Output FTA |
FS-TDIO-2430 | Digital Input/Output FTA for safety systems |
FS-USI-0001 | Universal Safety Interface Module |
FC-IOTA-R24 | Redundant I/O Termination Assembly |
FS-TPSU-2430 | Power Supply Module for Safety Controllers |
FS-TERM-0001 | Redundant I/O Bus Terminator |
Popular Honeywell Automation Modules (Same Brand)
Model Number | Description |
---|---|
CC-TDIL01 | Digital Input Module for C300 Controllers |
CC-PAIH01 | HART Analog Input Module |
CC-TDOR01 | Relay Output Module |
CC-PDOB01 | Digital Output Module |
CC-TCNT01 | Pulse Counter Module |
CC-TAOX11 | Analog Output Module |