Company Information | ||||||||
[email protected] | ||||||||
Mobile | +8613666033393 | |||||||
+8613666033393 | ||||||||
13666033393 | ||||||||
Add | Room 1004, No. 62 Xiangxiu Li, Siming District, Xiamen City, Fujian Province, China |
Product Introductio
The Honeywell 51202901-500 Connection Cable is a high-integrity, shielded communication cable developed for use in Honeywell’s industrial control systems, especially the TDC3000, TotalPlant Solution (TPS), and Experion PKS platforms. As part of Honeywell’s automation connectivity suite, this cable is engineered for critical applications that require stable, interference-free signal transmission between modules and subsystems.
With a standard 1-meter length, the cable offers compact connectivity within cabinets or between modules in distributed systems. It features pre-assembled, factory-terminated connectors which minimize installation time and errors. Built with industrial-grade materials and dual-layer shielding, this cable is optimized for performance in electrically noisy environments such as chemical plants, refineries, power stations, and manufacturing facilities.
Product Specifications
Parameter | Details |
---|---|
Model Number | Honeywell 51202901-500 |
Product Type | Shielded Communication/Connection Cable |
Cable Length | 1 meter (3.28 feet) |
Connector Type | Factory-installed proprietary Honeywell ends |
Conductor Material | Copper (multi-strand) |
Shielding | Braided + foil shield (double shielded) |
Jacket Material | PVC (Flame-retardant, UL 94V-0) |
Operating Voltage | 300V |
Insulation Resistance | ≥ 100 MΩ/km |
Operating Temperature | -20°C to +70°C |
Storage Temperature | -40°C to +85°C |
Cable Diameter | 8 mm |
Weight | 0.159 kg |
Certifications | UL, CE, RoHS compliant |
System Compatibility | TDC3000, TPS, Experion PKS |
Product Applications
The Honeywell 51202901-500 cable is specifically designed for use in:
-
Distributed Control Systems (DCS) such as TDC3000 and Experion PKS
-
I/O modules to control cabinet connections
-
Operator interface terminals and control processors
-
Field data acquisition systems
-
Redundant system communication links
-
Power generation and process automation
-
Chemical, petrochemical, and oil & gas industries
Product Advantages
-
High Signal Integrity:
Dual shielding (braided and foil) effectively blocks EMI/RFI, ensuring reliable data transfer. -
Quick Installation:
Pre-installed factory connectors eliminate manual termination and reduce human error. -
Industrial Durability:
Designed for harsh operating conditions with a tough PVC jacket and high-flex core. -
Space-Saving Design:
The 1-meter length makes it perfect for short-distance cabinet connections and reduces cable clutter. -
Compliance with Global Standards:
Fully certified for industrial use (UL, CE, RoHS), meeting international quality and safety benchmarks. -
Wide System Compatibility:
Specifically tailored for Honeywell’s DCS platforms such as TPS and Experion PKS, ensuring maximum performance and minimal configuration issues.
Frequently Asked Questions (FAQ)
1. How is this cable typically used in Honeywell’s control systems?
It’s most often installed between I/O modules and system cabinets or used to connect interface cards within the DCS architecture, particularly in TDC3000 and Experion PKS environments.
2. What makes this cable suitable for high-EMI industrial environments?
It features both braided and foil shielding, which provide excellent noise immunity in areas with heavy electrical interference such as near motors, inverters, or relay panels.
3. Can this cable support both analog and digital signals?
Yes. While designed for digital communications in Honeywell systems, its construction allows it to support analog signal transmission as well, depending on the application.
4. Are these cables interchangeable with third-party equivalents?
It’s not recommended. The 51202901-500 is tailored to Honeywell’s impedance and signal requirements. Using third-party alternatives may cause performance issues or damage system components.
5. What happens if the cable is bent sharply during installation?
Sharp bends can damage the shielding and degrade signal performance. The cable should be installed following Honeywell’s recommended minimum bend radius to preserve integrity.
6. Is there a part number suffix that indicates customization or connector variation?
Yes. Honeywell often uses suffixes like -501 or -600 to indicate different lengths or shielding enhancements. Always refer to the exact part number when ordering replacements.
7. Does this cable require grounding at both ends?
In most cases, grounding at one end is sufficient and preferred to avoid ground loops. Honeywell installation manuals will specify the grounding strategy for each application.
8. Can this cable be reused after system maintenance?
If removed carefully and connectors remain intact, it can be reused. However, due to potential degradation in shielding or physical stress, new cables are generally recommended for critical links.
9. What’s the most common reason for failure in this cable?
Physical damage from improper routing, excessive bending, or connector fatigue is the leading cause. Environmental degradation is rare if installed properly.
10. Is it possible to test the cable’s integrity in the field?
Yes. You can use a continuity tester or cable analyzer to check conductor paths, shielding, and resistance. Honeywell also provides test procedures for field diagnostics.
Related Models from the Same Series
Model Number | Description |
---|---|
51202901-501 | 2-meter shielded connection cable |
51202901-502 | 5-meter shielded connection cable |
51202901-600 | 1-meter high-flex, high-EMI-resistant version |
51400939-100 | Fieldbus connection cable (1 meter) |
51304485-100 | I/O module to terminal block cable (1 meter) |
51201420-100 | Redundant signal cable, shielded (1 meter) |
Popular Honeywell Models
Model Number | Product Type | Application |
---|---|---|
CC-PAIH01 | Analog Input Module | Universal analog signal acquisition |
CC-PAOH01 | Analog Output Module | Signal output to control actuators |
CC-TDIL01 | Digital Input Module (24V DC) | Input for discrete signals from field devices |
CC-TAIX01 | Analog Input Module | Multi-channel analog input for Experion PKS |
51400948-100 | Universal I/O Cable | Versatile communication cable |
CC-PDIL01 | Pulse Digital Input Module | High-speed pulse signal processing |