Honeywell RM7800M1011 Burner Control
- Product Details
- FAQs
- Related
- Contact Us
- Packing & Delivery
- Product Ratings

Product Overview
The Honeywell RM7800M1011 is a microprocessor-based burner control module designed for automatically fired gas, oil, or combination fuel single-burner applications. It provides advanced sequencing, flame supervision, system diagnostics, and status indication, ensuring reliable and safe burner operation.
Applications
The RM7800M1011 is suitable for:
-
Industrial and commercial boilers
-
Furnaces and ovens
-
Kilns and incinerators
-
Any single-burner system requiring SIL3-capable safety
Advantages
-
Microprocessor precision with non-volatile memory
-
SIL3 safety capability with self-checking logic
-
Wide application flexibility with Modbus and other communication options
-
First-out annunciation and detailed fault diagnostics
-
Interchangeable flame amplifiers for various detection types
-
Robust design operating from -40°C to +60°C
Technical Specifications
| Parameter | Value |
|---|---|
| Power Supply | 120 Vac, 50/60 Hz |
| Power Dissipation | 10 W (module), 3 W (display) |
| Max Connected Load | 2000 VA |
| Operating Temperature | -40°C to +60°C |
| Storage Temperature | -40°C to +66°C |
| Humidity | 85% RH non-condensing |
| Vibration Resistance | 0.5G |
| Dimensions | 127 x 127 x 133 mm |
| Weight | 0.7 kg |
FAQ
Q1: What type of burners can the RM7800M1011 control?
A1: It is designed for single-burner gas, oil, or combination fuel systems.
Q2: Does the RM7800M1011 support remote monitoring?
A2: Yes, it supports Modbus™ communication and remote reset options.
Q3: What safety standard does it comply with?
A3: It is SIL3 capable when used in an appropriate safety system.
Q4: Can it retain fault history after a power loss?
A4: Yes, thanks to its non-volatile memory.
Q5: What is the Flame Failure Response Time (FFRT)?
A5: Between 0.8 and 3.0 seconds depending on amplifier type.
Q6: What is included in a typical system setup?
A6: Relay module, keyboard display, subbase, amplifier, and purge card.
Q7: How does it indicate faults?
A7: Through its display module and optional expanded annunciators.
Q8: Can it operate in cold environments?
A8: Yes, it works down to -40°C.
Q9: Does it perform self-diagnostics?
A9: Yes, dynamic self-check and amplifier checks are performed regularly.
Q10: What is the maximum total connected electrical load?
A10: Up to 2000 VA.
Related Honeywell Models (Same Series or Compatible)
| Model | Description | Dimensions (mm) | Weight (kg) |
|---|---|---|---|
| RM7800E1012 | Relay Module (modulating) | 127x127x133 | 0.7 |
| RM7800G1015 | Relay Module (modulating) | 127x127x133 | 0.7 |
| RM7800L1087 | Relay Module with VPS | 127x127x133 | 0.7 |
| S7800A1001 | Keyboard Display (English) | 127x127x25 | 0.1 |
| Q7800A1005 | Panel Mount Subbase | 127x127x20 | 0.2 |
| R7847A1023 | Flame Signal Amplifier | 60x40x25 | 0.05 |
Popular Honeywell Models
| Model | Description | Dimensions (mm) | Weight (kg) |
|---|---|---|---|
| R7849A1023 | Ultraviolet Amplifier | 60x40x25 | 0.05 |
| C7027A1023 | Minipeeper UV Detector | 100x30x30 | 0.15 |
| C7061A1012 | UV Flame Detector | 200x80x60 | 1.2 |
| S7830A1005 | Expanded Annunciator | 150x100x50 | 0.5 |
| S7810M1003 | Modbus Communication Module | 100x60x30 | 0.2 |
| S7820A1007 | Remote Reset Module | 100x60x30 | 0.2 |
FAQ
Q1: What type of burners can the RM7800M1011 control?
A1: It is designed for single-burner gas, oil, or combination fuel systems.
Q2: Does the RM7800M1011 support remote monitoring?
A2: Yes, it supports Modbus™ communication and remote reset options.
Q3: What safety standard does it comply with?
A3: It is SIL3 capable when used in an appropriate safety system.
Q4: Can it retain fault history after a power loss?
A4: Yes, thanks to its non-volatile memory.
Q5: What is the Flame Failure Response Time (FFRT)?
A5: Between 0.8 and 3.0 seconds depending on amplifier type.
Q6: What is included in a typical system setup?
A6: Relay module, keyboard display, subbase, amplifier, and purge card.
Q7: How does it indicate faults?
A7: Through its display module and optional expanded annunciators.
Q8: Can it operate in cold environments?
A8: Yes, it works down to -40°C.
Q9: Does it perform self-diagnostics?
A9: Yes, dynamic self-check and amplifier checks are performed regularly.
Q10: What is the maximum total connected electrical load?
A10: Up to 2000 VA.
Related Honeywell Models (Same Series or Compatible)
| Model | Description | Dimensions (mm) | Weight (kg) |
|---|---|---|---|
| RM7800E1012 | Relay Module (modulating) | 127x127x133 | 0.7 |
| RM7800G1015 | Relay Module (modulating) | 127x127x133 | 0.7 |
| RM7800L1087 | Relay Module with VPS | 127x127x133 | 0.7 |
| S7800A1001 | Keyboard Display (English) | 127x127x25 | 0.1 |
| Q7800A1005 | Panel Mount Subbase | 127x127x20 | 0.2 |
| R7847A1023 | Flame Signal Amplifier | 60x40x25 | 0.05 |
Popular Honeywell Models
| Model | Description | Dimensions (mm) | Weight (kg) |
|---|---|---|---|
| R7849A1023 | Ultraviolet Amplifier | 60x40x25 | 0.05 |
| C7027A1023 | Minipeeper UV Detector | 100x30x30 | 0.15 |
| C7061A1012 | UV Flame Detector | 200x80x60 | 1.2 |
| S7830A1005 | Expanded Annunciator | 150x100x50 | 0.5 |
| S7810M1003 | Modbus Communication Module | 100x60x30 | 0.2 |
| S7820A1007 | Remote Reset Module | 100x60x30 | 0.2 |
| Company Information | ||||||||
| [email protected] | ||||||||
| Mobile | +8613666033393 | |||||||
| +8613666033393 | ||||||||
| 13666033393 | ||||||||
| Add | Room 1004, No. 62 Xiangxiu Li, Siming District, Xiamen City, Fujian Province, China | |||||||
Excellent PLC Co., Ltd. has a large number of brand new and original PLC and DCS spare parts, with more than 60 cooperative countries. All products are guaranteed for 1 year and delivered to you by high-quality express. We are committed to using the best products and the most favorable prices to meet the needs and friendship of our customers. We have won the trust of thousands of customers, including these excellent customers.
As for the delivery time, when we receive your order requirements, we will arrange for warehouse personnel to test and verify the products. After you place the order, we will send it to you within 24 hours.
Excellent PLC