Product Description
The HIMA HIMatrix F60 GEH 01 is a modular safety-related controller subrack designed for critical industrial automation applications. It accommodates the F60 system’s power supply, central, and I/O modules in a compact, reliable structure. Engineered for harsh environments, it ensures secure and stable mounting with integrated fans and earth grid.
Technical Specifications
| Parameter | Value |
|---|---|
| Material | Aluminum, anodized, partially coated |
| Slots | 8 (1 for PSU, 1 for CPU, 6 for I/O) |
| Horizontal pitch | 40 HP |
| Modules per DIN EN 60297-3 | 4 HP per module |
| Connector type | DIN EN 60603-2, Type C, 96-pole |
| Fan part number | 39 2003001 |
| Ambient temperature | 0…+60 °C |
| Storage temperature | -40…+85 °C |
| Humidity | <95% RH, non-condensing |
| Protection class | IP20 |
| Power supply | 24 V DC |
| Dimensions (W×H×D) | 259 × 310 × 228 mm |
| Weight | Approx. 1.5 kg |
Applications
-
Industrial process automation
-
Emergency shutdown (ESD) systems
-
Railway signaling and control (with GEH 014 variant)
-
Zone 2 hazardous area installations (ATEX compliant)
-
SIL-rated safety applications in oil, gas, and power industries
Advantages
-
Compact and modular design for flexible configurations
-
Supports up to 6 I/O modules in addition to PSU and CPU
-
Integrated fans for improved cooling and reliability
-
Certified for use in hazardous areas (Zone 2) with proper enclosure
-
High resistance to environmental factors (temperature, shock, vibration)
FAQ
Q1: How many modules can the GEH 01 accommodate?
A1: Up to 8 modules—1 power supply, 1 CPU, and 6 I/O modules.
Q2: Is the GEH 01 suitable for Zone 2 hazardous environments?
A2: Yes, when installed in a certified enclosure meeting IP54 or higher.
Q3: What power supply is required?
A3: A 24 V DC power supply unit with PELV or SELV isolation.
Q4: Does the subrack itself perform safety functions?
A4: No, safety functions are implemented by the installed modules, not the subrack.
Q5: How often should the fans be replaced?
A5: Every 5 years at normal temperatures or every 3 years if >40 °C.
Q6: What is the recommended storage temperature?
A6: Between -40 °C and +85 °C.
Q7: What material is used for the housing?
A7: Anodized and partially coated aluminum.
Q8: Is maintenance required during operation?
A8: No, the subrack itself is maintenance-free aside from fan replacement.
Q9: Can modules be replaced while powered?
A9: Work in a de-energized state is recommended for safety.
Q10: What is the protection rating of the subrack?
A10: IP20 by default, higher when installed in suitable enclosures.
Recommended Related Models
| Model | Description | Dimensions (mm) | Weight |
|---|---|---|---|
| HIMA HIMatrix F60 GEH 014 | Railway-compliant variant with coated electronics | 259 × 310 × 228 | 1.5 kg |
| HIMA HIMatrix F60 CPU 01 | Central processing unit module | 4 HP width (per slot) | ~0.3 kg |
| HIMA HIMatrix F60 PSU 01 | Power supply module | 4 HP width (per slot) | ~0.4 kg |
| HIMA HIMatrix F60 DI 01 | Digital input module | 4 HP width (per slot) | ~0.3 kg |
| HIMA HIMatrix F60 DO 01 | Digital output module | 4 HP width (per slot) | ~0.3 kg |
| HIMA HIMatrix F60 AI 01 | Analog input module | 4 HP width (per slot) | ~0.3 kg |
Popular HIMA Models
| Model | Description | Dimensions (mm) | Weight |
|---|---|---|---|
| HIMA HIMax X-CPU 01 | High-availability CPU module | 4 HP width (per slot) | ~0.4 kg |
| HIMA HIMax X-PSU 01 | Redundant power supply module | 4 HP width (per slot) | ~0.4 kg |
| HIMA HIMatrix F35 | Compact safety controller | 134 × 140 × 113 | ~1.2 kg |
| HIMA HIMatrix F3 AIO8 | Compact analog/digital I/O | 134 × 140 × 113 | ~1.2 kg |
| HIMA HIMatrix F3 DO8 | Compact digital output module | 134 × 140 × 113 | ~1.2 kg |
| HIMA Planar4 F8627X | Fail-safe relay module | 140 × 180 × 110 | ~0.8 kg |
Excellent PLC