Honeywell RM7800L1087 Burner Control Excellent PLC Co.,Ltd

PLC and DCS professional supplier

Honeywell RM7800L1087 Burner Control

Manufacturer:Honeywell

Product Number:RM7800L1087

Product Type:Burner Control

Origin:USA

Dimensions:127 x 127 x 133 mm

Weight:0.83 kg

Views:134

Payment Methods:T/T, PayPal, Western Union

Condition:New & In Stock

Shipping Port:Xiamen, China

Warranty:1 Year

Lead Time:1-3 Working Days

Certificate:COO

Courier partners:DHL, UPS, TNT, FedEx and EMS.

Business hours:7*24


  • Product Details
  • FAQs
  • Related
  • Contact Us
  • Packing & Delivery
  • Product Ratings
Company Information
E-mail [email protected]
Mobile +8613666033393
Whatsapp +8613666033393
WeChat 13666033393
Add Room 1004, No. 62 Xiangxiu Li, Siming District, Xiamen City, Fujian Province, China

Honeywell RM7800L1087 Burner Control

Product Description

The Honeywell RM7800L1087 is a microprocessor-based burner control relay module designed for automatic sequencing, flame supervision, system status display, and diagnostics of single-burner gas, oil, or combination fuel applications. It delivers advanced safety and control functions, replacing conventional burner controls.


Product Applications

  • Industrial gas and oil-fired burners

  • Boilers, furnaces, ovens, and kilns

  • Applications requiring SIL3-capable safety instrumentation

  • Systems needing Modbus™ communication and extended diagnostics

  • Single burner systems in commercial and industrial environments


Product Advantages

  • SIL3 capable for high safety integrity

  • Advanced diagnostics and fault history logging

  • Flame failure response time as fast as 0.8 seconds

  • Flexible post purge settings up to 60 minutes

  • Robust safety checks and tamper-resistant logic

  • Modbus™ interface and local/remote annunciation options

  • Nonvolatile memory retains status and history after power loss


Technical Specifications

Parameter Specification
Dimensions 127 × 127 × 133 mm
Weight 0.83 kg
Operating Voltage 120 VAC ±10%, 50/60 Hz
Power Dissipation Max 10 W (Relay), Max 3 W (Display)
Ambient Temperature -40°C to +60°C operating
Humidity 85% RH non-condensing
Mounting Options Panel, wall, or burner with subbase
Flame Failure Response Time 0.8 to 3.0 seconds (depending on amplifier)
Communication Optional Modbus™ interface
Safety Certification SIL3 capable, UL, CSA, FM approvals

FAQ

Q1: What fuel types does the RM7800L1087 support?
A1: It supports gas, oil, or combination fuel systems.

Q2: What is the flame failure response time?
A2: Depending on the amplifier, it ranges from 0.8 to 3.0 seconds.

Q3: Can this module communicate with building management systems?
A3: Yes, through the optional Modbus™ communication module.

Q4: What is the maximum adjustable post purge time?
A4: Up to 60 minutes, with 15 seconds as the default setting.

Q5: Is this product suitable for continuous burner operation?
A5: Yes, it is designed for burners with either intermittent or continuous operation.

Q6: Does it provide fault history logging?
A6: Yes, it records the six most recent faults with detailed data.

Q7: What safety certifications does it have?
A7: UL, CSA, FM, and SIL3 capable in proper configurations.

Q8: What is the maximum load it can handle?
A8: The total connected load is up to 2000 VA with 15A fast-blow fuse protection.

Q9: How is the RM7800L1087 mounted?
A9: Using the Q7800 subbase for panel, wall, or burner mounting.

Q10: Does it retain its settings after a power outage?
A10: Yes, it uses nonvolatile memory to retain history and sequence status.


Recommended Related Models (Same Series or Similar)

Model Number Description Dimensions (mm) Weight (kg)
RM7800E1012 Relay Module, basic model 127 × 127 × 133 0.83
RM7800G1003 Relay Module, intermittent pilot 127 × 127 × 133 0.83
RM7800M1002 Relay Module, on/off 127 × 127 × 133 0.83
RM7840L1075 Burner Control, programmable 127 × 127 × 133 0.83
RM7890A1015 Basic Programmer Module 127 × 127 × 133 0.83
RM7895A1014 Integrated Burner Controller 127 × 127 × 133 0.83

Popular Honeywell Models

Model Number Description Dimensions (mm) Weight (kg)
R7910A1005 Integrated Burner Control 127 × 127 × 133 0.83
R7886A1020 Flame Amplifier, UV Self-check 127 × 127 × 133 0.83
R7861A1022 Flame Amplifier, Dynamic Check 127 × 127 × 133 0.83
R7847A1025 Flame Amplifier, Rectification 127 × 127 × 133 0.83
R7852A1008 Infrared Flame Amplifier 127 × 127 × 133 0.83
R7849A1033 Flame Amplifier, UV Minipeeper 127 × 127 × 133 0.83

FAQ

Q1: What fuel types does the RM7800L1087 support?
A1: It supports gas, oil, or combination fuel systems.

Q2: What is the flame failure response time?
A2: Depending on the amplifier, it ranges from 0.8 to 3.0 seconds.

Q3: Can this module communicate with building management systems?
A3: Yes, through the optional Modbus™ communication module.

Q4: What is the maximum adjustable post purge time?
A4: Up to 60 minutes, with 15 seconds as the default setting.

Q5: Is this product suitable for continuous burner operation?
A5: Yes, it is designed for burners with either intermittent or continuous operation.

Q6: Does it provide fault history logging?
A6: Yes, it records the six most recent faults with detailed data.

Q7: What safety certifications does it have?
A7: UL, CSA, FM, and SIL3 capable in proper configurations.

Q8: What is the maximum load it can handle?
A8: The total connected load is up to 2000 VA with 15A fast-blow fuse protection.

Q9: How is the RM7800L1087 mounted?
A9: Using the Q7800 subbase for panel, wall, or burner mounting.

Q10: Does it retain its settings after a power outage?
A10: Yes, it uses nonvolatile memory to retain history and sequence status.

Recommended Related Models (Same Series or Similar)

Model Number Description Dimensions (mm) Weight (kg)
RM7800E1012 Relay Module, basic model 127 × 127 × 133 0.83
RM7800G1003 Relay Module, intermittent pilot 127 × 127 × 133 0.83
RM7800M1002 Relay Module, on/off 127 × 127 × 133 0.83
RM7840L1075 Burner Control, programmable 127 × 127 × 133 0.83
RM7890A1015 Basic Programmer Module 127 × 127 × 133 0.83
RM7895A1014 Integrated Burner Controller 127 × 127 × 133 0.83

Popular Honeywell Models

Model Number Description Dimensions (mm) Weight (kg)
R7910A1005 Integrated Burner Control 127 × 127 × 133 0.83
R7886A1020 Flame Amplifier, UV Self-check 127 × 127 × 133 0.83
R7861A1022 Flame Amplifier, Dynamic Check 127 × 127 × 133 0.83
R7847A1025 Flame Amplifier, Rectification 127 × 127 × 133 0.83
R7852A1008 Infrared Flame Amplifier 127 × 127 × 133 0.83
R7849A1033 Flame Amplifier, UV Minipeeper 127 × 127 × 133 0.83

Honeywell RM7800L1087 Burner Control

Company Information
E-mail [email protected]
Mobile +8613666033393
Whatsapp +8613666033393
WeChat 13666033393
Add Room 1004, No. 62 Xiangxiu Li, Siming District, Xiamen City, Fujian Province, China

Excellent PLC Co., Ltd. has a large number of brand new and original PLC and DCS spare parts, with more than 60 cooperative countries. All products are guaranteed for 1 year and delivered to you by high-quality express. We are committed to using the best products and the most favorable prices to meet the needs and friendship of our customers. We have won the trust of thousands of customers, including these excellent customers.

As for the delivery time, when we receive your order requirements, we will arrange for warehouse personnel to test and verify the products. After you place the order, we will send it to you within 24 hours.

Click to rate this post!
[Total: 0 Average: 0]

Prev:

Next:

Leave a message