Product Introduction
Emerson’s KJ3001X1-BD1 discrete input module is a high-performance I/O component designed for Emerson’s DeltaV control system. It is specifically designed to process a variety of digital input signals and reliably and accurately monitor the on/off status of field devices such as switches, sensors, and relays.
As a member of the DeltaV Series 2 I/O product family, the KJ3001X1-BD1 offers advanced diagnostic capabilities, easy integration, and seamless communication with DeltaV controller networks. Its rugged design ensures stable operation in harsh industrial environments, making it ideal for process automation, manufacturing control, and safety-critical systems.
Product Specifications
| Range | value |
|---|---|
| model | KJ3001X1-BD1 |
| Manufacturer | Emerson Electric Company |
| Product Type | Discrete input modules |
| System compatibility | Emerson DeltaV Series 2 I/O |
| Input Channel | 16 isolated discrete inputs |
| Input voltage range | 12–24 VDC (nominal) |
| Input signal type | Dry contact, wet contact, TTL logic |
| Isolation | Channel-to-channel isolation and channel-to-ground isolation |
| Update rate | Typical value <50 milliseconds |
| Diagnostic features | Channel fault detection, line integrity monitoring |
| Communication interface | DeltaV I/O Bus |
| Power consumption | Typical value 3 W |
| Operating temperature | -20°C to +55°C |
| Storage temperature | -40°C to +85°C |
| Humidity range | 5%–95% non-condensing |
| Protection Rating | IP20 (module housing) |
| Certifications | UL, CE, ATEX, IECEx |
| Compliance Standards | IEC 61131-2, EN 61000-6-2, EN 61000-6-4 |
| Mounting Type | Plug-in to DeltaV carrier rail |
| Dimensions (W × H × D) | 107 x 41 x 105 mm |
| Weight | 0.181 kg |
Product Applications
-
Process Automation: Monitoring digital signals in chemical, oil & gas, and water treatment plants.
-
Manufacturing Control: Integrating sensors and switches into automated production systems.
-
Power Generation: Used in turbine control, substation automation, and energy monitoring.
-
Safety Instrumented Systems (SIS): Detecting and processing safety-critical digital inputs.
-
Building Automation: Collecting on/off status from HVAC and lighting control systems.
-
Machine Control: Interfacing with limit switches and emergency stop buttons.
-
Remote I/O Systems: Providing digital input monitoring for distributed control networks.
Product Advantages
-
High Channel Density: 16 isolated channels for efficient use of panel space.
-
Advanced Diagnostics: Built-in fault detection reduces troubleshooting time.
-
Seamless Integration: Fully compatible with Emerson DeltaV control architecture.
-
Flexible Input Support: Accepts both dry and wetted contacts for versatile field use.
-
Robust Isolation: Ensures signal integrity and protects against electrical interference.
-
Fast Response: Low update rate for time-sensitive control applications.
-
Industrial Durability: Operates reliably in harsh environmental conditions.
-
Plug-and-Play Installation: Hot-swappable design simplifies maintenance and upgrades.
FAQ
-
How many discrete inputs does the KJ3001X1-BD1 support?
It supports 16 isolated digital input channels. -
What input voltage range is accepted by this module?
It operates with discrete input signals in the 12–24 VDC range. -
Does the module provide channel-to-channel isolation?
Yes, each channel is electrically isolated to ensure signal integrity. -
Can the KJ3001X1-BD1 detect line integrity faults?
Yes, it includes diagnostics for open-wire and line fault detection. -
Is this module compatible with all DeltaV carriers?
It is compatible with DeltaV Series 2 I/O carriers and backplanes. -
What type of field devices can be connected to this module?
It supports dry contact switches, wetted contacts, and TTL logic devices. -
Can the module be hot-swapped without shutting down the system?
Yes, it supports online replacement to minimize downtime. -
What is the typical scan/update rate of the module?
The module updates input status in less than 50 ms under typical conditions. -
Is the KJ3001X1-BD1 suitable for hazardous area applications?
Yes, it is certified for ATEX and IECEx hazardous areas when equipped with appropriate isolation barriers. -
Does the module support remote diagnostics over the DeltaV network?
Yes, it provides comprehensive diagnostics and status monitoring over the DeltaV control network.
Recommended related models
| model | describe | Main Features |
|---|---|---|
| KJ3001X1-BB1 | Discrete output modules | 16-channel isolated digital output |
| KJ3001X1-BG1 | Analog input modules | High-precision analog signal acquisition |
| KJ3001X1-BF1 | Analog output module | Precise control of analog actuators |
| KJ3001X1-BA1 | HART analog input module | Analog input with HART communication |
| KJ3001X1-BC1 | Pulse input module | High-speed counting and pulse signal input |
| KJ3001X1-BE1 | Mixed-Signal I/O Modules | Combination of digital and analog channels |
Recommended popular Emerson models
| model | describe | Main Applications |
|---|---|---|
| KJ4001X1-CA1 | DeltaV Controller Module | Central processing unit of the DeltaV system |
| KJ3222X1-BA1 | Analog input terminal block | High-density analog signal terminal |
| KJ1501X1-BB1 | Power Module | Provides reliable power to I/O carriers |
| KJ3204X1-BB1 | Discrete output terminal blocks | Digital output interface field wiring |
| KJ4002X1-BE1 | DeltaV Network Interface Module | Ethernet and serial communication gateway |
| KJ2101X1-BB1 | Redundant power supply controller | Managing power redundancy in DeltaV systems |
Excellent PLC