| Company Information | ||||||||
| [email protected] | ||||||||
| Mobile | +8613666033393 | |||||||
| +8613666033393 | ||||||||
| 13666033393 | ||||||||
| Add | Room 1004, No. 62 Xiangxiu Li, Siming District, Xiamen City, Fujian Province, China | |||||||
Emerson VE4019P0 Series 2 Plus Redundant H1 Fieldbus Interface Card
- Product Details
- FAQs
- Related
- Contact Us
- Packing & Delivery
- Product Ratings

Product Overview
The Emerson VE4019P0 is a DeltaV™ M-series FOUNDATION™ Fieldbus Series 2 Plus interface card designed for redundant control applications. Featuring four high-performance H1 ports, it enables communication with multiple field devices using a single card and supports up to 16 devices per port. Ideal for modern digital process control systems, it maximizes device communication, diagnostics, and redundancy with ease.
Technical Specifications
| Parameter | Specification |
|---|---|
| Model Number | VE4019P0 |
| Number of Channels | 4 Ports |
| Devices per Port | Up to 16 |
| Signal Type | FOUNDATION Fieldbus (IEC 61158-2) |
| Localbus Current | 200 mA typical, 300 mA max |
| Field Circuit Power | 9–12 V DC, 12 mA per channel |
| Isolation | 1000V DC (2s) isolation per channel |
| Operating Temperature | -40 to 70°C (-40 to 158°F) |
| Storage Temperature | -40 to 85°C (-40 to 185°F) |
| Relative Humidity | 5–95%, non-condensing |
| Vibration | 1 mm p-p (5–13.2 Hz); 0.7 g (13.2–150 Hz) |
| Shock | 10 g, 11 ms |
| Protection Class | IP20 |
| Airborne Contaminants | ISA-S71.04 G3 with conformal coating |
| Certifications | CE, FM, CSA, ATEX, IEC-Ex, Marine (ABS, DNV) |
| Dimensions (W x H x D) | 107 x 41 x 105 mm |
| Weight | 0.3 kg |
Applications
-
Process industries requiring high-availability field communication
-
Petrochemical, chemical, and pharmaceutical manufacturing
-
Power plants and energy generation facilities
-
Redundant, multi-device control networks in critical applications
-
Automation systems requiring FOUNDATION Fieldbus connectivity
Key Advantages
-
Redundant Control: 1:1 active-standby redundancy with automatic switchover
-
High Device Density: Up to 64 devices per card (16 per port)
-
Multi-Drop Efficiency: Simplifies wiring and reduces cost
-
Smart Device Support: Full utilization of diagnostics and data from FF devices
-
Easy Commissioning: Auto-sense and auto-configure for new/standby cards
-
Robust Design: Meets G3 airborne contaminant standards with conformal coating
-
Seamless Integration: Compatible with AMS Device Manager and DeltaV v13.3.1+
Frequently Asked Questions (FAQ)
Q1: How many field devices can the VE4019P0 support?
A1: It supports up to 16 devices per port, totaling 64 devices per card.
Q2: Is the VE4019P0 compatible with redundant systems?
A2: Yes, it provides full 1:1 redundancy with automatic switchover.
Q3: Can the card be replaced while the system is powered?
A3: Yes, hot-swapping is supported in safe areas.
Q4: What DeltaV version is required for this module?
A4: DeltaV v13.3.1 or higher is required.
Q5: Does it support third-party FOUNDATION Fieldbus devices?
A5: Yes, provided they meet Emerson’s compatibility requirements.
Q6: What environmental protection rating does it meet?
A6: It meets IP20 and ISA-S71.04 G3 class with conformal coating.
Q7: What happens during a card failure?
A7: The system automatically switches to the standby card without user intervention.
Q8: Can the card be used in hazardous environments?
A8: Yes, it is certified for FM, ATEX, IEC-Ex, and marine use.
Q9: How is diagnostic information accessed?
A9: Through DeltaV diagnostics explorer and AMS Device Manager.
Q10: What kind of field wiring is required?
A10: Standard fieldbus wiring with power supplies and terminators for each segment.
Related Models (Same Series or Function)
| Model Number | Description | Ports | Redundancy | Dimensions (mm) | Weight |
|---|---|---|---|---|---|
| VE4039P0 | Redundant H1 Interface, 4 Ports, Two-wide Termination Block | 4 | Yes | 107 x 82 x 105 | 0.6 kg |
| KC3030X1-BA3 | H1 Fieldbus Card Series 2 Plus, Four Segments | 4 | No | 107 x 41 x 105 | 0.3 kg |
| KC4011X1-BL1 | Termination Block for Simplex H1 | – | No | – | – |
| KC4011X1-BF1 | Termination Block for Redundant H1 | – | Yes | – | – |
| VE4018P0 | Simplex H1 FF Interface, 2-Port Series 2 | 2 | No | 107 x 41 x 105 | 0.3 kg |
| VE4020P0 | Redundant H1 FF Interface, 2-Port Series 2 | 2 | Yes | 107 x 82 x 105 | 0.6 kg |
Popular Emerson Models
| Model Number | Description | Function | Dimensions (mm) | Weight |
|---|---|---|---|---|
| KJ3001X1-BB1 | Analog Input 12 Channels, DeltaV M-Series | AI Module | 107 x 41 x 105 | 0.3 kg |
| KJ3204X1-BA1 | 4-Channel Thermocouple Input Module | Temperature Input | 107 x 41 x 105 | 0.3 kg |
| KJ4001X1-BA2 | HART Enabled Analog Output 8 Channels | AO Module | 107 x 41 x 105 | 0.3 kg |
| KJ3241X1-BA1 | 32 Channel Digital Input Module | DI Module | 107 x 41 x 105 | 0.3 kg |
| KJ3221X1-BA1 | 16 Channel Digital Output | DO Module | 107 x 41 x 105 | 0.3 kg |
| KJ4010X1-BF1 | Redundant Ethernet Interface for DeltaV Controller | Network Redundancy | 107 x 41 x 105 | 0.3 kg |
Frequently Asked Questions (FAQ)
Q1: How many field devices can the VE4019P0 support?
A1: It supports up to 16 devices per port, totaling 64 devices per card.
Q2: Is the VE4019P0 compatible with redundant systems?
A2: Yes, it provides full 1:1 redundancy with automatic switchover.
Q3: Can the card be replaced while the system is powered?
A3: Yes, hot-swapping is supported in safe areas.
Q4: What DeltaV version is required for this module?
A4: DeltaV v13.3.1 or higher is required.
Q5: Does it support third-party FOUNDATION Fieldbus devices?
A5: Yes, provided they meet Emerson’s compatibility requirements.
Q6: What environmental protection rating does it meet?
A6: It meets IP20 and ISA-S71.04 G3 class with conformal coating.
Q7: What happens during a card failure?
A7: The system automatically switches to the standby card without user intervention.
Q8: Can the card be used in hazardous environments?
A8: Yes, it is certified for FM, ATEX, IEC-Ex, and marine use.
Q9: How is diagnostic information accessed?
A9: Through DeltaV diagnostics explorer and AMS Device Manager.
Q10: What kind of field wiring is required?
A10: Standard fieldbus wiring with power supplies and terminators for each segment.
Related Models (Same Series or Function)
| Model Number | Description | Ports | Redundancy | Dimensions (mm) | Weight |
|---|---|---|---|---|---|
| VE4039P0 | Redundant H1 Interface, 4 Ports, Two-wide Termination Block | 4 | Yes | 107 x 82 x 105 | 0.6 kg |
| KC3030X1-BA3 | H1 Fieldbus Card Series 2 Plus, Four Segments | 4 | No | 107 x 41 x 105 | 0.3 kg |
| KC4011X1-BL1 | Termination Block for Simplex H1 | – | No | – | – |
| KC4011X1-BF1 | Termination Block for Redundant H1 | – | Yes | – | – |
| VE4018P0 | Simplex H1 FF Interface, 2-Port Series 2 | 2 | No | 107 x 41 x 105 | 0.3 kg |
| VE4020P0 | Redundant H1 FF Interface, 2-Port Series 2 | 2 | Yes | 107 x 82 x 105 | 0.6 kg |
Popular Emerson Models
| Model Number | Description | Function | Dimensions (mm) | Weight |
|---|---|---|---|---|
| KJ3001X1-BB1 | Analog Input 12 Channels, DeltaV M-Series | AI Module | 107 x 41 x 105 | 0.3 kg |
| KJ3204X1-BA1 | 4-Channel Thermocouple Input Module | Temperature Input | 107 x 41 x 105 | 0.3 kg |
| KJ4001X1-BA2 | HART Enabled Analog Output 8 Channels | AO Module | 107 x 41 x 105 | 0.3 kg |
| KJ3241X1-BA1 | 32 Channel Digital Input Module | DI Module | 107 x 41 x 105 | 0.3 kg |
| KJ3221X1-BA1 | 16 Channel Digital Output | DO Module | 107 x 41 x 105 | 0.3 kg |
| KJ4010X1-BF1 | Redundant Ethernet Interface for DeltaV Controller | Network Redundancy | 107 x 41 x 105 | 0.3 kg |
| Company Information | ||||||||
| [email protected] | ||||||||
| Mobile | +8613666033393 | |||||||
| +8613666033393 | ||||||||
| 13666033393 | ||||||||
| Add | Room 1004, No. 62 Xiangxiu Li, Siming District, Xiamen City, Fujian Province, China | |||||||
Excellent PLC Co., Ltd. has a large number of brand new and original PLC and DCS spare parts, with more than 60 cooperative countries. All products are guaranteed for 1 year and delivered to you by high-quality express. We are committed to using the best products and the most favorable prices to meet the needs and friendship of our customers. We have won the trust of thousands of customers, including these excellent customers.
As for the delivery time, when we receive your order requirements, we will arrange for warehouse personnel to test and verify the products. After you place the order, we will send it to you within 24 hours.
Excellent PLC