Yokogawa AAI143-S00/K4A00 Analog Input Module Excellent PLC Co.,Ltd

PLC and DCS professional supplier

Yokogawa AAI143-S00/K4A00 Analog Input Module

Manufacturer:Yokogawa

Product Number:AAI143-S00/K4A00

Product Type:Analog Input Module

Origin:Japan

Dimensions:107.5 × 32.8 × 130 mm

Weight:0.3 kg

Views:100

Payment Methods:T/T, PayPal, Western Union

Condition:New & In Stock

Shipping Port:Xiamen, China

Warranty:1 Year

Lead Time:1-3 Working Days

Certificate:COO

Courier partners:DHL, UPS, TNT, FedEx and EMS.

Business hours:7*24


  • Product Details
  • FAQs
  • Related
  • Contact Us
  • Packing & Delivery
  • Product Ratings
Company Information
E-mail [email protected]
Mobile +8613666033393
Whatsapp +8613666033393
WeChat 13666033393
Add Room 1004, No. 62 Xiangxiu Li, Siming District, Xiamen City, Fujian Province, China

Yokogawa AAI143-S00/K4A00 Analog Input Module

Product Overview

The Yokogawa AAI143-S00/K4A00 is a 16-channel, isolated analog input module designed for precise current signal acquisition in control systems. It supports 4 to 20 mA DC input signals and offers HART communication functionality for enhanced device diagnostics and configuration. This module is typically used in field control systems requiring high signal integrity and electrical isolation.


Technical Specifications

Parameter Specification
Model AAI143-S00/K4A00
Input Channels 16 (Isolated)
Input Signal 4 to 20 mA DC
Input Resistance (Power ON) 270 Ω (20 mA) to 350 Ω (4 mA)
Input Resistance (Power OFF) ≥ 500 kΩ
Allowable Input Current Max. 24 mA
Accuracy ±16 µA
Temperature Drift ±16 µA/10°C
Data Update Period 10 ms
Withstanding Voltage 1500 V AC (1 min) between input and system
Transmitter Power Supply 19.0 V (min at 20 mA), 25.5 V (max at 0 mA), limit 25 mA
Maximum Current Consumption 230 mA (5 V DC), 540 mA (24 V DC)
HART Communication Supported
External Connection Pressure clamp terminal, MIL connector, KS cable
Dimensions (W × H × D) 107.5 × 32.8 × 130 mm
Weight 0.3 kg

Applications

  • Process control systems in refineries and petrochemical plants

  • Power generation plants (including renewables and fossil fuel)

  • Water and wastewater treatment facilities

  • Pulp and paper manufacturing

  • Pharmaceutical and biotechnology automation


Product Advantages

  • Channel Isolation: Improves signal integrity and prevents ground loop issues.

  • High Accuracy: ±16 µA accuracy for precision analog measurement.

  • HART Protocol Support: Enables real-time device diagnostics and configuration.

  • Wide Compatibility: Compatible with multiple FCS systems such as AFV, AFG, AFF series.

  • Flexible Terminal Options: Supports KS cable and pressure clamp terminals.

  • Redundancy Support: Operates in dual-redundant configurations.


FAQs

Q1: How many input channels does the AAI143-S00/K4A00 module support?
A1: It supports 16 isolated current input channels.

Q2: What type of input signals can it handle?
A2: It handles 4 to 20 mA DC current signals.

Q3: Is HART communication supported?
A3: Yes, it supports HART communication for enhanced field device integration.

Q4: What is the power consumption of the module?
A4: It consumes 230 mA at 5 V DC and 540 mA at 24 V DC.

Q5: Can this module be used with 2-wire transmitters?
A5: Yes, each channel supports 2-wire or 4-wire transmitters via pin setting.

Q6: Is the module suitable for hazardous area applications?
A6: Yes, when used with an isolation barrier (Zener barriers are not allowed).

Q7: What is the update rate of the data from this module?
A7: Data is updated every 10 milliseconds.

Q8: What systems is this module compatible with?
A8: Compatible with Yokogawa field control units like AFV30, AFV40, AFF50, and AFG series.

Q9: What’s the isolation voltage rating?
A9: 1500 V AC between input and system for one minute.

Q10: How is the module connected externally?
A10: Via pressure clamp terminal block, MIL connector, or KS cable interface.


Related or Same-Series Models

Model Input Type Channels Isolation HART Support Dimensions (mm) Weight
AAI135 4–20 mA Current 8 Yes Yes 107.5×32.8×130 0.3 kg
AAI141 4–20 mA Current 16 No Yes 107.5×32.8×130 0.2 kg
AAB141 1–5 V / 4–20 mA 16 No Yes 107.5×32.8×130 0.3 kg
AAI841 4–20 mA (I/O) 8/8 No Yes 107.5×32.8×130 0.3 kg
AAV144 -10 to +10 V 16 Yes No 107.5×32.8×130 0.2 kg
AAI543 4–20 mA Output 16 Yes Yes 107.5×32.8×130 0.4 kg

Popular Yokogawa Models

Model Description Type Channels HART Dimensions (mm) Weight
AAI143 Analog Input Module (Isolated) Analog Input 16 Yes 107.5×32.8×130 0.3 kg
AAI543 Analog Output Module (Isolated) Analog Output 16 Yes 107.5×32.8×130 0.4 kg
AAV144 Voltage Input Module (Isolated) Analog Input 16 No 107.5×32.8×130 0.2 kg
AAT141 Thermocouple/mV Input Module TC/mV Input 16 No 107.5×32.8×130 0.2 kg
AAI135 Analog Input Module (Isolated Channels) Analog Input 8 Yes 107.5×32.8×130 0.3 kg
AAI835 Analog I/O Module (Isolated Channels) Analog I/O 4/4 Yes 107.5×32.8×130 0.3 kg

FAQs

Q1: How many input channels does the AAI143-S00/K4A00 module support?
A1: It supports 16 isolated current input channels.

Q2: What type of input signals can it handle?
A2: It handles 4 to 20 mA DC current signals.

Q3: Is HART communication supported?
A3: Yes, it supports HART communication for enhanced field device integration.

Q4: What is the power consumption of the module?
A4: It consumes 230 mA at 5 V DC and 540 mA at 24 V DC.

Q5: Can this module be used with 2-wire transmitters?
A5: Yes, each channel supports 2-wire or 4-wire transmitters via pin setting.

Q6: Is the module suitable for hazardous area applications?
A6: Yes, when used with an isolation barrier (Zener barriers are not allowed).

Q7: What is the update rate of the data from this module?
A7: Data is updated every 10 milliseconds.

Q8: What systems is this module compatible with?
A8: Compatible with Yokogawa field control units like AFV30, AFV40, AFF50, and AFG series.

Q9: What’s the isolation voltage rating?
A9: 1500 V AC between input and system for one minute.

Q10: How is the module connected externally?
A10: Via pressure clamp terminal block, MIL connector, or KS cable interface.

Related or Same-Series Models

Model Input Type Channels Isolation HART Support Dimensions (mm) Weight
AAI135 4–20 mA Current 8 Yes Yes 107.5×32.8×130 0.3 kg
AAI141 4–20 mA Current 16 No Yes 107.5×32.8×130 0.2 kg
AAB141 1–5 V / 4–20 mA 16 No Yes 107.5×32.8×130 0.3 kg
AAI841 4–20 mA (I/O) 8/8 No Yes 107.5×32.8×130 0.3 kg
AAV144 -10 to +10 V 16 Yes No 107.5×32.8×130 0.2 kg
AAI543 4–20 mA Output 16 Yes Yes 107.5×32.8×130 0.4 kg

Popular Yokogawa Models

Model Description Type Channels HART Dimensions (mm) Weight
AAI143 Analog Input Module (Isolated) Analog Input 16 Yes 107.5×32.8×130 0.3 kg
AAI543 Analog Output Module (Isolated) Analog Output 16 Yes 107.5×32.8×130 0.4 kg
AAV144 Voltage Input Module (Isolated) Analog Input 16 No 107.5×32.8×130 0.2 kg
AAT141 Thermocouple/mV Input Module TC/mV Input 16 No 107.5×32.8×130 0.2 kg
AAI135 Analog Input Module (Isolated Channels) Analog Input 8 Yes 107.5×32.8×130 0.3 kg
AAI835 Analog I/O Module (Isolated Channels) Analog I/O 4/4 Yes 107.5×32.8×130 0.3 kg

Yokogawa AAI143-S00/K4A00 Analog Input Module

Company Information
E-mail [email protected]
Mobile +8613666033393
Whatsapp +8613666033393
WeChat 13666033393
Add Room 1004, No. 62 Xiangxiu Li, Siming District, Xiamen City, Fujian Province, China

Excellent PLC Co., Ltd. has a large number of brand new and original PLC and DCS spare parts, with more than 60 cooperative countries. All products are guaranteed for 1 year and delivered to you by high-quality express. We are committed to using the best products and the most favorable prices to meet the needs and friendship of our customers. We have won the trust of thousands of customers, including these excellent customers.

As for the delivery time, when we receive your order requirements, we will arrange for warehouse personnel to test and verify the products. After you place the order, we will send it to you within 24 hours.

Click to rate this post!
[Total: 0 Average: 0]

Prev:

Next:

Leave a message