Product Introduction
The Yokogawa SSC50D-S2121 Duplexed Safety Control Unit is a high-reliability component designed for use in safety instrumented systems (SIS). It ensures continuous and secure operation by providing duplexed (redundant) control, minimizing the risk of single-point failures. This control unit is primarily implemented in critical industrial processes where system safety and uninterrupted performance are of utmost importance, such as oil & gas, petrochemical, power generation, and chemical plants.
Technical Specifications
| Parameter | Description |
|---|---|
| Model | Yokogawa SSC50D-S2121 Duplexed Safety Control Unit |
| Control Type | Duplexed safety control (redundant configuration) |
| Processor | High-performance dual-redundant CPU |
| Power Supply | 24 VDC (redundant input supported) |
| Dimensions | 482.6 x 266 x 88.1 mm |
| Weight | 8.5 kg |
| Operating Temperature | 0 to 55 °C |
| Storage Temperature | -20 to 70 °C |
| Certifications | SIL3 (IEC 61508 compliant), IEC 61511 ready |
| Diagnostic Functions | Self-checking, error detection, watchdog timer |
| Mounting | Cabinet rack mounting |
| System Redundancy | CPU, power supply, and communication redundancy |
Product Applications
-
Emergency shutdown (ESD) systems in oil refineries
-
Burner management systems in power plants
-
Process safeguarding in petrochemical complexes
-
Safety control in gas processing facilities
-
Chemical reactor overpressure and temperature protection
-
Integrated safety system (ISS) applications in distributed control systems (DCS)
Product Advantages
-
High Reliability: Duplex architecture ensures continuous operation even if one module fails.
-
Safety-Certified: Designed to comply with SIL3, ensuring the highest level of safety integrity.
-
Redundancy at Multiple Levels: CPU, power, and communication redundancy minimize downtime risk.
-
Advanced Diagnostics: Continuous self-checking and fault isolation allow for proactive maintenance.
-
Flexible Integration: Easily integrates with Yokogawa’s ProSafe-RS and other control environments.
-
Scalability: Suitable for both small-scale safety systems and large-scale plant-wide safety integration.
-
Extended Lifecycle Support: Built for long-term plant use with backward compatibility and vendor support.
FAQ
Q1: How does the SSC50D-S2121 handle CPU redundancy?
A1: The unit employs dual CPUs running in parallel. If one fails, the second CPU continues execution seamlessly without disrupting safety functions.
Q2: What safety standard level does the SSC50D-S2121 comply with?
A2: It is certified to SIL3 under IEC 61508, making it suitable for high-integrity safety functions.
Q3: Can the SSC50D-S2121 be integrated with ProSafe-RS?
A3: Yes, it is fully compatible with Yokogawa ProSafe-RS, enabling unified safety and process control management.
Q4: What happens if a power supply unit fails?
A4: The duplex power configuration ensures continuous operation. The system automatically switches to the redundant supply without interruption.
Q5: Does the SSC50D-S2121 support hot swapping of modules?
A5: Yes, critical modules such as power supply and CPU can be hot-swapped to minimize downtime.
Q6: What diagnostic features are available?
A6: The unit provides watchdog timers, error detection, continuous self-checking, and fault isolation to maintain system integrity.
Q7: How is communication redundancy achieved?
A7: It uses dual communication paths, ensuring that even if one network fails, the other maintains safe and reliable data transfer.
Q8: Can it be used in harsh environments?
A8: Yes, with its robust design, it supports operation in industrial temperature ranges and is resistant to vibration and electrical noise.
Q9: How is synchronization maintained between redundant CPUs?
A9: The CPUs constantly exchange state information over a high-speed internal bus, ensuring synchronized execution of safety logic.
Q10: What type of I/O modules can be connected?
A10: The SSC50D-S2121 supports Yokogawa safety I/O modules, including digital input, digital output, and analog input/output units designed for SIS applications.
Recommended Same-Series or Related Models
| Model | Description |
|---|---|
| SSC10D | Basic safety control unit for smaller systems |
| SSC20D | Standard safety control unit with redundancy options |
| SSC50D | Advanced safety control unit |
| SSC60D | Enhanced duplexed safety control with extended diagnostics |
| SSC100D | Large-scale system safety controller |
| SSC50D-S1111 | Earlier variant of duplexed safety controller |
Popular Yokogawa Models
| Model | Description |
|---|---|
| AAI141-S50 | Analog Input Module |
| AAI543-S50 | Analog Input Module |
| ADV151-P00 | Digital Input Module |
| ADV551-P00 | Digital Output Module |
| SAI143-H50 | Safety Analog Input Module |
| SDO141-S50 | Safety Digital Output Module |
| SEC401-50 | ESB Bus Coupler Module |
| SSC50D-S2121 | Duplexed Safety Control Unit |
FAQ
Q1: How does the SSC50D-S2121 handle CPU redundancy?
A1: The unit employs dual CPUs running in parallel. If one fails, the second CPU continues execution seamlessly without disrupting safety functions.
Q2: What safety standard level does the SSC50D-S2121 comply with?
A2: It is certified to SIL3 under IEC 61508, making it suitable for high-integrity safety functions.
Q3: Can the SSC50D-S2121 be integrated with ProSafe-RS?
A3: Yes, it is fully compatible with Yokogawa ProSafe-RS, enabling unified safety and process control management.
Q4: What happens if a power supply unit fails?
A4: The duplex power configuration ensures continuous operation. The system automatically switches to the redundant supply without interruption.
Q5: Does the SSC50D-S2121 support hot swapping of modules?
A5: Yes, critical modules such as power supply and CPU can be hot-swapped to minimize downtime.
Q6: What diagnostic features are available?
A6: The unit provides watchdog timers, error detection, continuous self-checking, and fault isolation to maintain system integrity.
Q7: How is communication redundancy achieved?
A7: It uses dual communication paths, ensuring that even if one network fails, the other maintains safe and reliable data transfer.
Q8: Can it be used in harsh environments?
A8: Yes, with its robust design, it supports operation in industrial temperature ranges and is resistant to vibration and electrical noise.
Q9: How is synchronization maintained between redundant CPUs?
A9: The CPUs constantly exchange state information over a high-speed internal bus, ensuring synchronized execution of safety logic.
Q10: What type of I/O modules can be connected?
A10: The SSC50D-S2121 supports Yokogawa safety I/O modules, including digital input, digital output, and analog input/output units designed for SIS applications.
Recommended Same-Series or Related Models
| Model | Description |
|---|---|
| SSC10D | Basic safety control unit for smaller systems |
| SSC20D | Standard safety control unit with redundancy options |
| SSC50D | Advanced safety control unit |
| SSC60D | Enhanced duplexed safety control with extended diagnostics |
| SSC100D | Large-scale system safety controller |
| SSC50D-S1111 | Earlier variant of duplexed safety controller |
Popular Yokogawa Models
| Model | Description |
|---|---|
| AAI141-S50 | Analog Input Module |
| AAI543-S50 | Analog Input Module |
| ADV151-P00 | Digital Input Module |
| ADV551-P00 | Digital Output Module |
| SAI143-H50 | Safety Analog Input Module |
| SDO141-S50 | Safety Digital Output Module |
| SEC401-50 | ESB Bus Coupler Module |
| SSC50D-S2121 | Duplexed Safety Control Unit |
| Company Information | ||||||||
| [email protected] | ||||||||
| Mobile | +8613666033393 | |||||||
| +8613666033393 | ||||||||
| 13666033393 | ||||||||
| Add | Room 1004, No. 62 Xiangxiu Li, Siming District, Xiamen City, Fujian Province, China | |||||||
Excellent PLC Co., Ltd. has a large number of brand new and original PLC and DCS spare parts, with more than 60 cooperative countries. All products are guaranteed for 1 year and delivered to you by high-quality express. We are committed to using the best products and the most favorable prices to meet the needs and friendship of our customers. We have won the trust of thousands of customers, including these excellent customers.
As for the delivery time, when we receive your order requirements, we will arrange for warehouse personnel to test and verify the products. After you place the order, we will send it to you within 24 hours.
Excellent PLC