Product Introduction
The HIMA F7115 High Performance Safety Module is a robust digital output module designed for integration into HIMA safety instrumented systems (SIS), including HIMax and HIQuad platforms. This module is engineered to provide fast, reliable, and safe output signals to critical field devices such as solenoids, actuators, relays, and motor starters.
The F7115 is built to support high-integrity safety applications, ensuring precise execution of safety logic for emergency shutdown systems, fire and gas systems, and turbine or generator protection. With SIL 3 certification according to IEC 61508, the module meets the most stringent industrial safety standards. Its advanced diagnostics, modular design, and compatibility with redundant architectures make it ideal for mission-critical industrial environments.
Product Parameters
Parameter | Specification |
---|---|
Module Type | High Performance Digital Output Module |
Output Channels | 16 isolated digital output channels |
Output Type | Relay / Transistor configurable outputs |
Safety Certification | SIL 3 certified per IEC 61508 |
Diagnostics | Channel fault detection, short/open circuit monitoring |
Response Time | <10 ms |
Voltage Range | 24 V DC / 48 V DC selectable |
Current Rating | Up to 2 A per channel |
Galvanic Isolation | Between channels and system bus |
Operating Temperature Range | -20 °C to +60 °C |
Storage Temperature Range | -40 °C to +85 °C |
Power Consumption | <10 W |
Dimensions (H × W × D) | 160 × 25 × 120 mm |
Weight | 0.4 kg |
Mounting | Rack-based or DIN-rail installation |
Product Applications
The F7115 High Performance Safety Module is suitable for multiple high-integrity safety and process automation applications:
-
Emergency Shutdown Systems (ESD): Activates valves, breakers, or actuators during unsafe operating conditions.
-
Fire and Gas Detection Systems (FGS): Controls alarms and safety devices to prevent accidents.
-
Turbine & Generator Protection: Executes trip functions and interlocks for high-speed protection.
-
High-Integrity Pressure Protection Systems (HIPPS): Drives safety outputs in oil, gas, and petrochemical facilities.
-
Process Automation: Reliable control of pumps, motors, and solenoids in critical chemical, pharmaceutical, or power generation processes.
-
Distributed Safety Systems: Integration into redundant safety architectures to ensure uninterrupted operation.
Product Advantages
-
SIL 3 Safety Certified: Complies with IEC 61508 for high-integrity safety applications.
-
High-Speed Response: Executes output signals with <10 ms response time.
-
Advanced Diagnostics: Detects short circuits, open circuits, and channel failures in real-time.
-
Versatile Output Configuration: Supports relay or transistor outputs to suit different field devices.
-
Redundant System Compatibility: Can be used in redundant architectures for high availability.
-
Compact Modular Design: Allows dense installation in control racks, optimizing space.
-
Robust Performance: Designed for harsh industrial environments with high electromagnetic noise immunity.
FAQ
-
What types of output signals does the F7115 support?
The module supports relay and transistor outputs configurable per channel. -
How many output channels are available on the module?
The F7115 provides 16 isolated digital output channels. -
Is the F7115 certified for safety applications?
Yes, it is SIL 3 certified according to IEC 61508. -
What is the maximum response time of the module?
The output response time is less than 10 milliseconds. -
Does the module include diagnostic monitoring?
Yes, it provides channel fault detection including open and short-circuit monitoring. -
Can the F7115 operate in redundant architectures?
Yes, it is fully compatible with redundant safety system configurations. -
What voltage and current ratings does the module support?
The module supports 24 V DC or 48 V DC outputs with up to 2 A per channel. -
Is galvanic isolation provided between channels?
Yes, each output channel is galvanically isolated from the system bus. -
Can the F7115 be integrated into existing HIMA safety systems?
Yes, it is compatible with HIMax, HIQuad, and other HIMA safety controllers. -
How does the module ensure reliable operation in harsh industrial environments?
It uses industrial-grade components, electromagnetic noise immunity design, and comprehensive diagnostics to maintain reliability.
Recommended Related Models (Same Series or Similar)
Model Number | Description | Channels | Output Type | Weight |
---|---|---|---|---|
F7111 | Digital Output Module | 8 | Relay/Transistor | 0.35 kg |
F7112 | High-Speed Output Module | 16 | Transistor | 0.38 kg |
F7113 | Mixed Output Module | 12 | Analog/Digital | 0.36 kg |
F7114 | Safety Output Module | 8 | Relay | 0.34 kg |
F7116 | Redundant Digital Output Module | 16 | Relay/Transistor | 0.42 kg |
F7117 | High Integrity Output Module | 16 | Relay/Transistor | 0.40 kg |
Recommended Popular Models (Same Brand, HIMA)
Model Number | Description | Application Area | Weight |
---|---|---|---|
F6204 | Analog Input Module | Process measurement and monitoring | 0.35 kg |
F7101 | Printed Circuit Board Module | Signal processing and I/O integration | 0.30 kg |
F7105 | Counter Module | Pulse and event counting | 0.32 kg |
F7130 | Temperature Input Module | RTD and thermocouple measurement | 0.34 kg |
F8650E | Communication Interface Module | System networking and redundancy | 0.40 kg |
F3236 | Digital Input Module | High-density input applications | 0.34 kg |