Product Introduction
The ABB 83SR05B-E GJR2360100R1100 is a high-reliability Battery Module designed to provide secure backup power for ABB’s process automation and control systems, particularly within the Symphony and INFI 90 systems. This module plays a critical role in ensuring data retention, real-time clock accuracy, and configuration integrity during power outages or planned maintenance operations.
Engineered for industrial-grade reliability, the 83SR05B-E battery module guarantees uninterrupted support for memory functions within critical controller units such as CPUs, I/O modules, and communication interfaces. Its durable, maintenance-free design minimizes operational downtime, making it essential for any continuous process control architecture where system integrity is paramount.
Product Specifications
Parameter | Details |
---|---|
Product Name | Battery Module |
Model Number | 83SR05B-E |
Part Number | GJR2360100R1100 |
Function | Backup power for memory/data retention |
Battery Chemistry | Lithium-based |
Voltage Rating | 3.6V (nominal) |
Capacity | 2.4 Ah |
Battery Life Expectancy | 5 to 10 years (depending on usage and environment) |
Typical Backup Duration | Supports SRAM/RTC up to several weeks/months |
Rechargeable | No (Primary lithium cell) |
Connection Type | Plug-in connector (pre-configured for ABB systems) |
Status Monitoring | Yes (via system diagnostics) |
Operating Temperature | -20°C to +60°C |
Storage Temperature | -40°C to +85°C |
Humidity Range | 5% – 95% (non-condensing) |
Mounting Method | Module/rack-mounted |
Safety Features | Short-circuit protection, thermal stability |
Compliance | RoHS, CE, EN61010 |
Dimensions (W x H x D) | 18 x 197 x 261 mm |
Weight | 0.46 kg |
Product Applications
The ABB 83SR05B-E battery module is primarily used in applications that require persistent memory support and protection of system configurations during power loss. It is suitable for:
-
DCS Systems in Power Plants: Ensures system parameter retention in turbines, boiler controls, and generator synchronizers.
-
Oil and Gas Refineries: Maintains critical logging and safety data in SCADA controllers.
-
Chemical Processing Units: Preserves batch recipe data and configuration files during shutdowns.
-
Pharmaceutical Plants: Guarantees compliance with process integrity for GMP regulations.
-
Water & Wastewater Treatment: Prevents loss of historical data and calibration in telemetry systems.
-
Manufacturing Facilities: Supports programmable controller memory during emergency stops or restarts.
Product Advantages
-
Long Operational Life: Up to a decade of battery life ensures minimal need for replacement and reduced maintenance overhead.
-
System Compatibility: Specially engineered for ABB INFI 90 and Symphony Plus platforms, ensuring plug-and-play integration.
-
Data Integrity Protection: Keeps controller and I/O configurations intact during blackouts or reboots.
-
Thermal Resilience: Functions reliably in wide industrial temperature ranges.
-
Compact and Modular: Small form factor enables flexible installation even in dense control racks.
-
Diagnostic Support: Integrated into ABB control platforms to alert users of low battery or end-of-life status.
-
No Recharging Required: Designed as a primary battery, eliminating the need for recharging circuits or maintenance tasks.
-
Field Proven: Trusted globally in mission-critical installations with a reputation for durability.
Frequently Asked Questions (FAQ)
-
What system platforms is the 83SR05B-E compatible with?
-
It is specifically designed for ABB Symphony and INFI 90 automation systems.
-
-
How long does the battery last under normal conditions?
-
Typical lifespan is 5 to 10 years, depending on ambient temperature and load.
-
-
Is the battery module rechargeable?
-
No, it uses a primary lithium cell that is non-rechargeable.
-
-
How does the module notify the user of battery failure?
-
Integrated diagnostics within the control system alert the operator of a low battery.
-
-
What is the module used for?
-
It backs up volatile memory and real-time clocks in automation controllers during power loss.
-
-
Can I replace the battery without shutting down the system?
-
In many configurations, it can be hot-swapped, depending on system design.
-
-
Is this module compatible with ABB 800xA systems?
-
It is primarily used with Symphony/INFI 90 systems; compatibility with 800xA depends on architecture.
-
-
What environmental conditions can it operate in?
-
It operates in temperatures from -20°C to +60°C and is stable in high-humidity environments.
-
-
Are there any safety certifications for the 83SR05B-E?
-
Yes, it meets RoHS, CE, and EN61010 standards.
-
-
Can I use third-party batteries as a replacement?
-
ABB recommends only using official 83SR05B-E modules to ensure safety and compatibility.
-
Recommended Related Models (Same Series / Application Field)
Model Number | Description | Function | Compatibility |
---|---|---|---|
83SR04-E | System Battery Module (Legacy) | Memory backup | INFI 90 legacy systems |
83SR06B-E | Extended Capacity Battery Module | Extended runtime for critical units | Symphony Plus/INFI 90 |
83BA01 | System Battery Backup Unit | RTC and SRAM backup | INFI 90 Controller Systems |
81CS01 | Control Power Supply with Battery Port | Power & battery integration | Modular I/O systems |
83TC01-E | Temperature Compensated Battery Module | Improved thermal performance | Harsh environment systems |
83BT02 | Battery Tray for Multi-Cell Integration | Holds multiple battery units | Redundant battery configurations |
Popular ABB Models (Same Brand, High Demand)
Model Number | Description | Application | Category |
---|---|---|---|
PM864AK01 | AC 800M Controller | High-performance process control | CPU/Controller |
AI810 | Analog Input Module | Analog signal acquisition | I/O Module |
CI854AK01 | PROFIBUS Communication Module | Field device integration | Communication Module |
DO810 | Digital Output Module (24V Source) | Actuation interface | I/O Module |
TU810V1 | I/O Terminal Unit | I/O connection management | Accessories |
PM902F | Redundant CPU for Symphony Plus Systems | High-availability process applications | Redundant Control Module |