Product Introduction
The ABB Bailey NLIS01 6636690AI Loop Interface Slave Module is an essential component in ABB’s INFI 90 Distributed Control System (DCS) architecture. Designed to serve as a communication interface between control modules and field loops, the NLIS01 provides seamless connectivity and accurate data exchange across multiple control nodes. It operates as a “slave” in a loop interface network, receiving data from loop master modules and facilitating real-time signal processing between central controllers and remote field devices.
The NLIS01 is particularly well-suited for process automation environments such as chemical plants, refineries, water treatment facilities, and power generation stations. Its robust performance, high communication reliability, and long service life make it a trusted module for critical industrial processes.
Product Specifications
Parameter | Description |
---|---|
Model Number | NLIS01 |
ABB Part Number | 6636690AI |
Product Type | Loop Interface Slave Module |
System Compatibility | INFI 90, Symphony Harmony |
Communication Protocol | Proprietary INFI 90 Bus |
Data Rate | Up to 2 Mbps (INFI 90 Loop) |
Power Supply | 5 V DC (from backplane) |
Mounting Style | DIN rail / card rack |
Indicators | LED status indicators for power, communication, and diagnostics |
Operating Temperature Range | 0°C to +60°C |
Storage Temperature | -40°C to +85°C |
Humidity | 5% to 95% non-condensing |
Cooling | Passive air cooling |
Dimensions (H x W x D) | 130 x 30 x 200 mm |
Weight | 0.771 kg |
Certifications | CE, UL, RoHS Compliant |
Housing Material | Metal shielded enclosure |
Diagnostic Capability | Built-in self-diagnostics and error reporting |
Product Applications
The ABB NLIS01 module is widely used in process automation industries where secure and real-time communication is vital. Its key applications include:
-
Power Plants: Integrates various sensors and controllers within turbine and boiler systems.
-
Chemical Processing Plants: Facilitates safe and controlled reactions by ensuring accurate loop feedback.
-
Oil & Gas Refineries: Communicates between field instruments and the DCS for pressure, flow, and temperature control.
-
Water & Wastewater Treatment: Provides precise control and monitoring of water quality and pump operations.
-
Pulp & Paper Mills: Ensures synchronization of multiple process stages such as bleaching, pulping, and drying.
-
Pharmaceutical Manufacturing: Helps in maintaining strict environmental and process standards via tight loop control.
Product Advantages
-
High Communication Reliability: Ensures error-free data exchange over the INFI 90 network with minimal latency.
-
Robust Construction: Metal-enclosed design provides strong protection against electromagnetic interference (EMI).
-
Seamless Integration: Compatible with both legacy and modern ABB control systems, ensuring upgrade flexibility.
-
Diagnostics & Monitoring: Built-in LEDs and diagnostics simplify troubleshooting and maintenance.
-
Compact Design: Small form factor allows for dense installation in control cabinets or racks.
-
Low Maintenance: Reliable performance reduces the need for frequent servicing or part replacement.
-
Long-Term Availability: Supported by ABB’s commitment to lifecycle support and spare part supply.
-
Optimized for Harsh Environments: Wide operating temperature range and industrial-grade components.
-
Plug-and-Play Architecture: Reduces downtime and simplifies module replacement in live systems.
-
Field-Proven Reliability: Trusted by industries worldwide for decades in mission-critical systems.
Frequently Asked Questions (FAQ)
-
What is the primary function of the NLIS01 module?
It serves as a slave device in the INFI 90 loop interface system, handling data exchange between master controllers and field devices. -
Is the NLIS01 compatible with the ABB Symphony Harmony system?
Yes, the NLIS01 is fully compatible with both Symphony Harmony and INFI 90 DCS platforms. -
Can the NLIS01 operate in high-temperature environments?
Yes, it supports operation in temperatures up to 60°C, suitable for most industrial environments. -
Does this module require external power?
No, it receives power from the backplane when installed in a compatible ABB rack system. -
What communication speed does the NLIS01 support?
It supports communication speeds up to 2 Mbps via the proprietary INFI 90 bus. -
Is the NLIS01 hot-swappable?
It is designed for easy replacement but should be swapped following ABB’s recommended safety procedures. -
Does this module come with onboard diagnostics?
Yes, it has built-in diagnostic functions and LED indicators for status monitoring. -
How often does this module need maintenance?
Under normal conditions, the NLIS01 requires minimal maintenance beyond routine inspection and cleaning. -
Can I use the NLIS01 with third-party controllers?
It is optimized for ABB control systems and may not function reliably with third-party controllers. -
What happens if the NLIS01 fails during operation?
The system will raise a communication fault; ABB recommends keeping a spare module to reduce downtime.
Related Models (Same Series / Functionally Similar)
Model Number | Description | System Compatibility |
---|---|---|
NLIM01 | Loop Interface Master Module | INFI 90 / Symphony Harmony |
INNIS01 | Network Interface Slave Module | INFI 90 |
INNPM01 | Network Processing Module | INFI 90 / Symphony Harmony |
NIS01 | Network Interface Slave (legacy model) | INFI 90 |
INICT13A | Communication Interface Module | INFI 90 |
INNIS21 | Advanced Network Interface Slave Module | INFI 90 / Harmony |
Popular ABB Bailey Models
Model Number | Description | Function/Use Case |
---|---|---|
INFI90 | Core DCS System Platform | Distributed Control System |
INNPM11 | Network Processing Module | Control & Data Processing |
INICT03A | Communication Interface Module | Serial & Ethernet Networking |
IMMFP12 | Multi-Function Processor Module | Control Execution |
INNIS11 | Network Interface Slave | DCS Communication Interface |
IMASI23 | Analog Input Module | Analog Signal Acquisition |