Product Introduction
The ABB Bailey PHARPS00010000 is a high-performance phasor measurement unit (PMU) designed for advanced power system monitoring and control. It is part of ABB’s Bailey series, renowned for its reliability and precision in electrical grid applications. This device provides real-time synchrophasor measurements, enabling utilities to enhance grid stability, detect faults, and optimize power distribution.
Product Parameters
Parameter | Specification |
---|---|
Model Number | PHARPS00010000 |
Input Voltage | 100-240V AC, 50/60Hz |
Measurement Range | 0-150V (Phase), 0-5A (Current) |
Accuracy | ±0.1% (Voltage), ±0.2% (Current) |
Communication | Ethernet, IEC 61850, Modbus |
Sampling Rate | Up to 60 samples per cycle |
Dimensions | 120 x 60 x 100mm |
Weight | 0.8 kg |
Operating Temp. | -20°C to +60°C |
Protection Class | IP54 (Dust and splash resistant) |
Product Applications
The ABB Bailey PHARPS00010000 is widely used in:
-
Wide-Area Monitoring Systems (WAMS) – Provides real-time grid stability analysis.
-
Smart Grids – Enhances situational awareness and fault detection.
-
Renewable Energy Integration – Ensures stable power flow from wind/solar farms.
-
Microgrid Control – Optimizes distributed energy resource management.
-
Transmission & Distribution Networks – Improves reliability and reduces blackout risks.
Product Advantages
-
High Precision – Delivers accurate synchrophasor data for critical decision-making.
-
Robust Communication – Supports multiple protocols (IEC 61850, Modbus) for seamless integration.
-
Compact & Durable – IP54-rated enclosure ensures reliability in harsh environments.
-
Low Latency – Real-time data transmission for rapid grid response.
-
Scalability – Compatible with ABB’s suite of grid automation solutions.
Frequently Asked Questions (FAQ)
-
What is the primary function of the PHARPS00010000?
It measures synchronized phasor data (voltage, current, frequency) for grid monitoring. -
Does it support GPS time synchronization?
Yes, it uses GPS for precise time-stamping of measurements. -
What communication protocols are supported?
Ethernet, IEC 61850, and Modbus. -
Is this device suitable for outdoor installation?
Yes, its IP54 rating protects against dust and moisture. -
What is the typical response time for fault detection?
Less than 20 milliseconds. -
Can it integrate with existing SCADA systems?
Yes, it is compatible with most SCADA platforms. -
What is the expected lifespan of the device?
5+ years under normal operating conditions. -
Does it require regular calibration?
Annual calibration is recommended for optimal accuracy. -
Is backup power required?
An optional UPS is suggested for uninterrupted operation. -
How long is the warranty period?
The standard warranty is 1 years, subject to proper usage and conditions.
Recommended Related Models
Model Number | Description | Key Features |
---|---|---|
PHARPS00020000 | Enhanced PMU with wider voltage range | 300V input, higher sampling rate |
PHARPS00030000 | Compact PMU for microgrids | DIN-rail mounting, low power consumption |
PHARPS00040000 | Ruggedized PMU for harsh environments | IP67, extended temperature range |
PHARPS00050000 | Multi-channel PMU | 12-phase monitoring, advanced analytics |
PHARPS00060000 | Wireless-enabled PMU | LTE/5G support, cloud integration |
PHARPS00070000 | Budget-friendly PMU | Basic synchrophasor functions |
Popular ABB Models in the Same Category
Model Number | Product Type | Key Applications |
---|---|---|
REF615 | Protection Relay | Grid protection, fault detection |
UNS0880A | Network Switch | Substation communication |
PCD2311A | Power Controller | Load management, energy optimization |
Relion 670 | Advanced Protection System | High-voltage transmission lines |
SSC600 | Substation Automation Controller | SCADA integration, grid control |
M2M 12-24DC | Power Supply Unit | Reliable DC power for PMUs/relays |