Company Information | ||||||||
[email protected] | ||||||||
Mobile | +8613666033393 | |||||||
+8613666033393 | ||||||||
13666033393 | ||||||||
Add | Room 1004, No. 62 Xiangxiu Li, Siming District, Xiamen City, Fujian Province, China |
Product Introduction
The ABB LT 8978B V1 HI024049-313 Pulse Amplifier is a highly reliable, high-performance signal amplification module specifically designed for industrial automation systems. As part of ABB’s extensive automation product portfolio, the LT 8978B V1 serves to amplify weak pulse signals, ensuring that the signals are suitable for further processing by control systems. It is particularly beneficial in applications where signal integrity is crucial, such as in remote sensors, measurement systems, and feedback loops within large industrial setups.
This amplifier is designed to work seamlessly with ABB’s distributed control systems (DCS), process controllers, and other automation platforms. It enhances the performance of sensor-driven systems by improving signal strength without introducing noise or distortion, which is critical in ensuring high operational accuracy and process stability. The module is built for robustness, operating in a wide range of environmental conditions typical of industrial environments.
Product Specifications
Parameter | Value |
---|---|
Product Name | Pulse Amplifier |
Model Number | LT 8978B V1 |
ABB Part Number | HI024049-313 |
Function | Signal amplification for pulse signals |
System Compatibility | ABB Advant OCS, Symphony, MOD300 |
Power Supply | 24 VDC ± 10% |
Input Type | Low-level pulse signals (both analog and digital) |
Output Type | Amplified pulse output, logic-level |
Operating Temperature | -20°C to +60°C |
Storage Temperature | -40°C to +85°C |
Humidity Range | 5% to 95% RH, non-condensing |
Signal Frequency Range | 1 Hz to 10 kHz |
Mounting Type | Modular chassis or DIN rail |
Diagnostics Features | Onboard LED status indicators |
Weight | 0.62 kg |
Dimensions (L x W x H) | 295 × 180 × 28 mm |
Compliance | CE, RoHS |
Certifications | UL, ISO 9001, IEC 61131 compliant |
Application Category | Industrial process control, sensor systems |
Product Applications
-
Industrial Automation
The LT 8978B V1 is used in factory automation systems, where it amplifies low-level pulse signals generated by sensors and transducers, ensuring accurate signal processing for control systems. -
Measurement and Monitoring Systems
In systems requiring precision measurements (e.g., flow meters, pressure sensors), the pulse amplifier ensures that weak signals are sufficiently amplified for further data analysis. -
Remote Monitoring
For remote monitoring applications in industries such as oil & gas, water treatment, and power generation, the amplifier boosts signal strength over long distances, ensuring data integrity and reliable communication. -
Process Control Systems
The module enhances feedback loops in distributed control systems (DCS), allowing for improved control accuracy, especially in critical process industries such as chemical manufacturing, power plants, and pharmaceuticals. -
Test and Calibration Systems
Used in test rigs and calibration systems for sensors and measurement equipment, the amplifier ensures signals from test equipment are amplified and standardized before analysis. -
Automated Safety Systems
Integrated into safety-critical automation systems to ensure that pulse-based signals, such as emergency shutdown triggers, are reliably transmitted and processed.
Product Advantages
-
Signal Clarity and Integrity
The LT 8978B V1 enhances weak signals without introducing distortion or noise, ensuring accurate and reliable data transmission within control systems. -
High Sensitivity and Wide Frequency Range
Capable of amplifying pulse signals across a broad frequency range (1 Hz to 10 kHz), the amplifier is adaptable to a wide range of industrial applications. -
Compact and Modular Design
Its compact form factor allows easy integration into existing system racks or DIN rail setups, providing flexibility in both new and retrofit installations. -
Reliable Diagnostic Capabilities
Equipped with diagnostic LEDs, the module allows operators to easily monitor operational status and quickly identify issues, minimizing system downtime. -
Industrial-Grade Durability
Designed to withstand harsh environmental conditions, including wide temperature variations, humidity, and electrical noise, making it suitable for use in critical applications. -
Energy Efficient
The amplifier is designed to operate at a low power consumption level, contributing to the overall energy efficiency of industrial systems.
FAQ
-
What type of pulse signals does the LT 8978B V1 amplify?
The LT 8978B V1 is designed to amplify both analog and digital pulse signals from low-level sources, improving signal clarity and strength. -
Can this amplifier work with high-frequency pulse signals?
Yes, the unit is capable of amplifying pulse signals within the frequency range of 1 Hz to 10 kHz, making it versatile for various applications. -
What is the maximum output power of the pulse amplifier?
The amplifier outputs pulse signals at logic-level voltage, suitable for direct interfacing with control systems, but the exact power depends on the system’s load conditions. -
Is this pulse amplifier compatible with all types of ABB control systems?
It is fully compatible with ABB’s distributed control systems like Advant OCS, MOD300, and Symphony, integrating easily into existing infrastructures. -
Does the amplifier support bidirectional pulse signal amplification?
The LT 8978B V1 supports amplification of pulse signals in a unidirectional flow from input to output, without bidirectional amplification capabilities. -
How does the amplifier handle signal distortion or noise during amplification?
The amplifier is designed with advanced noise suppression circuits to ensure the output pulse signal remains clear, free from unwanted distortion or electromagnetic interference (EMI). -
Can the amplifier be used in hazardous environments?
While it is built for industrial environments, further protective enclosures or intrinsically safe barriers may be required in hazardous areas to meet safety standards. -
What kind of power supply is required for the amplifier to operate?
The LT 8978B V1 operates with a 24 VDC power supply, which is common in industrial automation systems. -
How does the amplifier deal with signal overload?
The module includes built-in protection circuitry to prevent signal overload, ensuring the output remains stable and within safe operating limits. -
Are there any limitations to the types of pulse signals the amplifier can handle?
The primary limitation is the signal frequency range (1 Hz to 10 kHz). Pulse signals outside this range may not be effectively amplified or may require additional filtering.
Related Models (Same Series or Compatible)
Model | Description |
---|---|
LT 8978A V1 | Pulse amplifier for analog signals |
LT 8978C V1 | High-speed pulse amplifier for real-time applications |
LT 8980B V1 | Digital signal amplifier for sensor interfaces |
LT 8975A V1 | Low-level signal conditioning amplifier |
LT 8974B V1 | Amplifier for high-frequency pulse signals |
LT 8979C V1 | Integrated pulse amplifier with digital outputs |
Popular ABB Models (Other High-Demand Control Components)
Model | Function |
---|---|
PM864AK01 | ABB AC 800M Controller for high-performance automation |
CI853K01 | PROFIBUS DP Communication Interface Module |
AI845 | 8-channel analog input module (HART-compatible) |
DO880 | 16-channel digital output module (relay-type) |
TU810V1 | Terminal Unit for ABB’s S800 I/O system |
CI840A | Communication interface for ABB distributed I/O systems |