Product Introduction
The Bently Nevada 170190-01 Dual Galvanic Isolator is a precision-engineered signal conditioning module designed to electrically isolate input and output channels between field sensors and monitoring systems. This dual-channel isolator is particularly useful in safety-critical and high-noise industrial environments where electrical separation is essential to protect sensitive equipment and personnel.
Manufactured by Bently Nevada, a global leader in condition monitoring solutions under Baker Hughes, the 170190-01 provides robust galvanic isolation to prevent ground loops, minimize signal interference, and ensure the integrity of vibration and dynamic signal measurements. It plays a critical role in applications where accurate data transfer without common-mode voltage issues is required, such as in hazardous or power-intensive machinery monitoring.
Product Specifications
Parameter | Value |
---|---|
Model Number | 170190-01 |
Product Type | Dual Galvanic Isolator Module |
Channels | 2 Independent Galvanically Isolated Channels |
Input Type | Voltage or current input signals (depending on configuration) |
Output Type | Voltage output (analog), isolated from input |
Isolation Voltage | > 2500 V AC RMS (channel-to-channel and channel-to-ground) |
Frequency Response | 0 to 10 kHz (typical) |
Power Supply Voltage | 24 VDC (nominal), optional redundant input |
Power Consumption | ≤ 2.5 W |
Operating Temperature | -20°C to +70°C (-4°F to +158°F) |
Mounting Style | DIN rail or back panel mount |
Certifications | CE, UL, CSA, ATEX (model-dependent) |
Dimensions | 29.46 x 106.9 x 127 mm |
Weight | 0.2 kg |
Signal Integrity | < 0.1% signal distortion, low-noise design |
Connection Type | Screw terminals, labeled for easy identification |
Applications
The 170190-01 Dual Galvanic Isolator is widely used across heavy industrial sectors for:
-
Vibration signal isolation between field sensors and monitoring systems
-
Ground loop prevention in complex data acquisition environments
-
Rotating machinery diagnostics in power plants, refineries, and offshore platforms
-
Electrically noisy environments where signal protection is critical
-
Explosion-prone areas where safe electrical separation is required
-
PLC and DCS signal interfacing in condition-based maintenance systems
This unit enables reliable data transfer while protecting monitoring systems from high-voltage surges and transients.
Product Advantages
-
True Dual-Channel Design
Two completely independent channels allow for cost-effective signal isolation in dual-sensor systems. -
High Electrical Isolation
Rated at over 2500 V RMS, ensuring protection against voltage surges and electrical hazards. -
Signal Fidelity
Maintains the integrity of input signals with extremely low noise and minimal distortion. -
Flexible Mounting Options
Compact DIN rail or back panel mountable, saving valuable cabinet space. -
Enhanced Safety Compliance
Certified for use in industrial and potentially hazardous locations, depending on model variant. -
Long-Term Reliability
Designed to operate continuously in harsh environments without degradation of performance.
Frequently Asked Questions (FAQ)
-
What is the primary function of the Bently Nevada 170190-01?
It isolates input and output electrical signals, preventing ground loops and signal degradation in industrial monitoring systems. -
Can the two channels operate independently?
Yes, each channel is electrically isolated and functions independently. -
Is this device compatible with the Bently Nevada 3500 system?
Yes, it is often used to interface field signals with the 3500 monitoring rack. -
What type of signals can be isolated using this module?
Analog voltage signals, typically from transducers such as proximity or velocity sensors. -
Does it require a dedicated power supply?
Yes, it operates on 24 VDC and may support redundant power supply configurations. -
Can this be installed in hazardous areas?
Certain models may be certified for use in ATEX or Class I Div 2 environments. Check product label for specific certifications. -
What is the installation method?
The module can be DIN rail or back panel mounted inside control cabinets. -
Is calibration required during setup?
Factory calibration is provided, but fine-tuning may be necessary depending on system requirements. -
How long does the device last under continuous use?
Designed for industrial-grade performance, the unit can function reliably for over 10 years with proper conditions. -
Is there a risk of signal delay or loss?
No, the device is engineered to preserve signal timing and amplitude with minimal loss (<0.1%).
Related Models (Same Series or Function)
Model Number | Channels | Description |
---|---|---|
170190-01 | 2 | Dual-channel galvanic isolator module |
170191-01 | 1 | Single-channel version for isolated signal conditioning |
141716-01 | 1 | Galvanic isolator for buffered output applications |
147663-01 | 1 | Signal isolator cable with embedded isolation electronics |
140481-01 | 1 | Compact isolator accessory for sensor interfaces |
141709-0010-02 | N/A | Interface cable for galvanic isolators |
Popular Bently Nevada Models
Model Number | Type | Function |
---|---|---|
3500/42M | Vibration Monitor | Four-channel module for radial and thrust vibration |
3500/22M | Communications Gateway | Ethernet/Modbus interface for 3500 system |
330104-00-12-10-02 | Proximity Probe | Shaft vibration and position sensing |
3500/05 | System Rack | Chassis for up to 14 3500 series monitoring modules |
330130-040-00-00 | Extension Cable | For proximity transducer systems |
330980-70-00 | Laser Tachometer | Optical sensor for shaft speed detection |