Product Overview
The Bently Nevada 3500/33 184631-01F is a high-reliability 16-Channel Relay Output Module designed to work within the Bently Nevada 3500 Machinery Protection System. This module offers sixteen individually programmable Form-C relay outputs, allowing operators to control shutdown circuits, alarms, and external devices in response to machine conditions. With robust construction, integrated arc suppression, and advanced alarm logic, the 184631-01F enhances safety, reliability, and flexibility in industrial machinery protection systems.
Key Features
-
Sixteen independent Form-C (SPDT) relay outputs
-
Advanced alarm-drive logic with programmable AND/OR configurations
-
Full-height module occupying both front and rear rack slots
-
Epoxy-sealed relay contacts with integrated 250 Vrms arc suppression
-
Configurable relay grouping for normally energized or de-energized operation
-
Optional gold-plated low-current relay contacts for sensitive circuits
-
Front-panel LEDs indicating channel alarms, module OK, and communication status
-
Hot-swappable design (requires rack power off) for ease of maintenance
-
Designed for harsh industrial environments with global safety certifications
-
Fully compatible with Bently Nevada 3500 monitoring systems
Technical Specifications
Parameter | Specification |
---|---|
Module Type | 16-Channel Relay Output Module (Form-C SPDT) |
Dimensions | 241 x 24.4 x 242 mm |
Weight | 0.7 kg |
Relay Type | Epoxy-sealed electromechanical with arc suppression |
Standard Relay Ratings | 1 A @ 30 VDC or 125 VAC |
Low-Current Relay Ratings | 1 mA @ 1 VDC minimum, 100 mA @ 48 VDC maximum |
Arc Suppression | Integrated, rated at 250 Vrms |
Operating Temperature | -30°C to +65°C |
Storage Temperature | -40°C to +85°C |
Humidity Range | 0% to 95% RH, non-condensing |
Certifications | ATEX, IECEx, UL, CSA, RoHS, EMC compliant |
System Compatibility | Fully compatible with Bently Nevada 3500 System |
Typical Applications
-
Alarm signaling and shutdown control for turbines, compressors, and pumps
-
Integration with Safety Instrumented Systems (SIS) and Emergency Shutdown (ESD) circuits
-
Activation of external devices such as sirens, interlocks, annunciators, or indicator lights
-
Predictive maintenance and condition-based monitoring for rotating equipment
-
Centralized machinery protection in power plants, oil & gas, petrochemical, and manufacturing sectors
-
Flexible relay logic deployment for complex protection schemes
Product Advantages
-
Sixteen high-density relay outputs with full individual programmability
-
Supports customizable alarm logic with AND/OR configurations
-
Durable relay contacts with built-in arc suppression extend service life
-
Optional gold-plated contacts enhance performance in low-current circuits
-
Front-panel LEDs provide immediate status visibility for each channel
-
Hot-swappable module simplifies replacement and reduces downtime
-
Seamless integration with Bently Nevada 3500 rack systems
-
Built to withstand harsh industrial conditions, ensuring system reliability
-
Enhances overall plant safety by providing dependable machinery shutdown and alarm control
-
Compliant with global standards for hazardous and industrial environments
Frequently Asked Questions (FAQ)
-
What is the function of the 3500/33 184631-01F module?
It provides sixteen independent relay outputs to control alarms, shutdowns, and external devices. -
Can the relay outputs be programmed individually?
Yes, each relay can be configured with programmable alarm drive logic using AND/OR functions. -
What type of relay contacts are used?
SPDT (Form-C) electromechanical relays, with options for standard or low-current gold-plated versions. -
What is the maximum current supported by the relays?
Standard relays support up to 1 A at 30 VDC or 125 VAC. -
Does the module include arc suppression?
Yes, each relay is equipped with integrated 250 Vrms arc suppression to prevent contact damage. -
Is hot-swapping supported?
Yes, the module is hot-swappable but only when the rack power is turned off. -
Is the module suitable for use in hazardous environments?
Yes, it carries ATEX, IECEx, UL, CSA, RoHS, and EMC certifications. -
What are the operating temperature limits?
The module operates within -30°C to +65°C. -
How are relay groups configured?
Relay groups can be set for normally energized or de-energized operation, enhancing system safety. -
Where is the module commonly used?
In critical machinery protection systems for power generation, oil & gas, petrochemical, and industrial applications.
Recommended Related Models
Model | Description |
---|---|
Bently Nevada 3500/31 | 8-Channel Relay Output Module (Form-A relays) |
Bently Nevada 3500/32 | 8-Channel Alarm Relay Module |
Bently Nevada 3500/34 | 16-Channel Digital Input Module |
Bently Nevada 3500/36 | Thermocouple Input Module |
Bently Nevada 3500/55 | Dual-Channel Velocity Sensor Module |
Bently Nevada 3500/25 | Enhanced Keyphasor Module for speed/phase monitoring |
Popular Bently Nevada Models
Model | Description |
---|---|
Bently Nevada 3300 XL | Proximity and Vibration Monitoring System |
Bently Nevada 3500/40 | Velocity Sensor Module |
Bently Nevada 3500/46 | Temperature Sensor Module |
Bently Nevada 3500/60 | Programmable Alarm Module |
Bently Nevada 7200 | Wireless Vibration Monitoring System |
Bently Nevada 3500/33 | Alternate 16-Channel Relay Module |