Bently Nevada 60R/RLY01-00-0 Electro-Mech Relay Module Excellent PLC Co.,Ltd

PLC and DCS professional supplier

Bently Nevada 60R/RLY01-00-0 Electro-Mech Relay Module

Manufacturer:Bently Nevada

Product Number:60R/RLY01-00-0

Product Type:Electro-Mech Relay Module

Origin:USA

Dimensions:132.1 x 20.3 x 245.6 mm

Weight:1.2 kg

Views:94

Payment Methods:T/T, PayPal, Western Union

Condition:New & In Stock

Shipping Port:Xiamen, China

Warranty:1 Year

Lead Time:1-3 Working Days

Certificate:COO

Courier partners:DHL, UPS, TNT, FedEx and EMS.

Business hours:7*24


  • Product Details
  • FAQs
  • Related
  • Contact Us
  • Packing & Delivery
  • Product Ratings
Company Information
E-mail [email protected]
Mobile +8613666033393
Whatsapp +8613666033393
WeChat 13666033393
Add Room 1004, No. 62 Xiangxiu Li, Siming District, Xiamen City, Fujian Province, China

Bently Nevada 60R/RLY01-00-0 Electro-Mech Relay Module

Product Introduction

The Bently Nevada 60R/RLY01-00-0 Electro-Mechanical Relay Module is a robust, high-reliability output module engineered for integration within the Bently Nevada 60R Series condition monitoring and protection platform. Designed to provide precise relay-based control, this module acts as the critical interface between machine condition monitoring data and plant-level protective actions. Whether used to trigger alarms, shut down machinery, or switch process controls, it ensures immediate and accurate response to abnormal conditions. With country-specific compliance codes and optional SIL (Safety Integrity Level) certification, it is suited for global installations in power generation, oil & gas, petrochemical, and heavy industrial applications where safety and reliability are paramount.


Technical Specifications

Parameter Details
Product Type Electro-Mechanical Relay Output Module
Model Number 60R/RLY01-00-0
System Platform Bently Nevada 60R Series
Relay Configuration 8 independent SPDT relays (form C)
Contact Rating 5 A at 250 VAC / 5 A at 30 VDC resistive load
Coil Drive Voltage 24 VDC nominal (operational range 18–36 VDC)
Switching Capacity 1250 VA AC / 150 W DC
Isolation 2500 Vrms channel-to-channel and channel-to-ground
Response Time <10 ms operate, <8 ms release
Communication Interfaces Modbus TCP/IP, OPC UA, Ethernet
Alarm Integration Supports trip, shutdown, and warning logic
Operating Temperature –20 °C to +70 °C (–4 °F to +158 °F)
Humidity Range 5%–95% non-condensing
Vibration Resistance 5 g, 5–2000 Hz
Shock Resistance 30 g, 11 ms half-sine
Country-Specific Codes Available for North America, EU, Asia-Pacific
SIL Certification Options SIL 1 or SIL 2 compliant (order-specific)
Dimensions (W × H × D) 132.1 x 20.3 x 245.6 mm
Weight 1.2 kg
Compliance CE, UL, RoHS

Applications

  • Machine Protection Systems: Provides direct relay outputs for alarm or trip activation when vibration, temperature, or process parameters exceed limits.

  • Process Control: Interfaces with plant control logic to open/close valves, start/stop pumps, or enable safety interlocks.

  • Redundant Safety Shutdown: Integrates with SIL-certified safety systems for critical equipment like turbines and compressors.

  • Alarm Signaling: Sends warning signals to DCS/SCADA systems to alert operators in real time.

  • Industrial Automation: Works with Modbus TCP/IP or OPC UA networks for seamless integration into automated workflows.

  • Offshore/Marine Operations: Designed to handle harsh environmental conditions with strong resistance to vibration and shock.


Advantages

  • High Relay Capacity: Each SPDT relay supports up to 5 A at 250 VAC or 30 VDC for versatile switching.

  • Fast Response: Sub-10 ms operate and release times ensure rapid protective actions.

  • Enhanced Safety Compliance: Optional SIL 1 or SIL 2 certification ensures adherence to global functional safety standards.

  • Electrical Isolation: 2500 Vrms isolation between channels prevents cross-talk and protects downstream equipment.

  • Flexible Communication: Built-in Modbus TCP/IP and OPC UA interfaces enable easy integration with plant control systems.

  • Compact 3U Form Factor: Fits seamlessly into the 60R chassis without increasing cabinet footprint.

  • Rugged Construction: Withstands high vibration and shock, ensuring reliability in demanding industrial settings.

  • Scalable Architecture: Multiple relay modules can be combined for larger systems or multi-point shutdown schemes.

  • Global Compatibility: Country-specific code options meet diverse regulatory requirements worldwide.

  • Low Maintenance: Durable electro-mechanical relays with long operational life reduce service intervals.


FAQ

  1. What type of relays are used in the 60R/RLY01-00-0 module?
    The module uses eight independent single-pole double-throw (SPDT) form-C electro-mechanical relays for flexible switching.

  2. What is the maximum current capacity of each relay contact?
    Each contact is rated for 5 A at 250 VAC or 5 A at 30 VDC for resistive loads.

  3. How fast do the relays operate and release?
    Typical operate time is less than 10 ms, with release time under 8 ms for rapid protective action.

  4. Can the module communicate with SCADA or DCS systems?
    Yes, it supports Ethernet, Modbus TCP/IP, and OPC UA protocols for seamless integration.

  5. Does the module provide electrical isolation between channels?
    Yes, it offers 2500 Vrms isolation between relay channels and ground to prevent interference.

  6. Is the module compatible with SIL-rated safety systems?
    It can be ordered with SIL 1 or SIL 2 certification to meet functional safety requirements.

  7. Can multiple relay modules be installed in one chassis?
    Absolutely, several RLY01-00-0 modules can be combined for systems needing more outputs.

  8. How does the module handle high vibration environments?
    It is tested to withstand vibration up to 5 g from 5–2000 Hz and shock up to 30 g.

  9. What power supply is required for operation?
    The relay coils operate from a nominal 24 VDC supply, with an acceptable range of 18–36 VDC.

  10. Does the module support remote alarm and trip configuration?
    Yes, alarm and trip thresholds can be configured remotely through the 60R system’s interface.


Related Models (Same Series)

Model Number Description Key Feature
60R/PPM01-00-0 Protection Processing Module Real-time trip and shutdown logic
60R/REC01-00-0 Recorder Output Module High-fidelity analog data recording
60R/CMM01-00 Condition Monitoring Module High-speed vibration and process analysis
60R/INP01-00-0 Prox/Accel/Velom Input Module Multi-sensor vibration and position inputs
60R/PIM01-00-0 3U Power Input Module Dual-input redundant power supply
60R/CHA02-00-0 3U Chassis Panel Houses and powers multiple 60R modules

Popular Bently Nevada Models

Model Number Description Application Focus
3500/42M Proximitor Monitoring Module Multi-channel vibration/position monitoring
3500/40M Vibration Monitor Machine protection with four-channel input
3500/22M Transient Data Interface Module High-resolution transient data acquisition
330104-00-20-10-02-05 Proximity Probe Precision shaft vibration measurement
330180-51-05 Velocity Sensor Seismic and structural vibration detection
330130-040-00 Extension Cable Low-noise signal transmission for probes

FAQ

  1. What type of relays are used in the 60R/RLY01-00-0 module?
    The module uses eight independent single-pole double-throw (SPDT) form-C electro-mechanical relays for flexible switching.

  2. What is the maximum current capacity of each relay contact?
    Each contact is rated for 5 A at 250 VAC or 5 A at 30 VDC for resistive loads.

  3. How fast do the relays operate and release?
    Typical operate time is less than 10 ms, with release time under 8 ms for rapid protective action.

  4. Can the module communicate with SCADA or DCS systems?
    Yes, it supports Ethernet, Modbus TCP/IP, and OPC UA protocols for seamless integration.

  5. Does the module provide electrical isolation between channels?
    Yes, it offers 2500 Vrms isolation between relay channels and ground to prevent interference.

  6. Is the module compatible with SIL-rated safety systems?
    It can be ordered with SIL 1 or SIL 2 certification to meet functional safety requirements.

  7. Can multiple relay modules be installed in one chassis?
    Absolutely, several RLY01-00-0 modules can be combined for systems needing more outputs.

  8. How does the module handle high vibration environments?
    It is tested to withstand vibration up to 5 g from 5–2000 Hz and shock up to 30 g.

  9. What power supply is required for operation?
    The relay coils operate from a nominal 24 VDC supply, with an acceptable range of 18–36 VDC.

  10. Does the module support remote alarm and trip configuration?
    Yes, alarm and trip thresholds can be configured remotely through the 60R system’s interface.

Related Models (Same Series)

Model Number Description Key Feature
60R/PPM01-00-0 Protection Processing Module Real-time trip and shutdown logic
60R/REC01-00-0 Recorder Output Module High-fidelity analog data recording
60R/CMM01-00 Condition Monitoring Module High-speed vibration and process analysis
60R/INP01-00-0 Prox/Accel/Velom Input Module Multi-sensor vibration and position inputs
60R/PIM01-00-0 3U Power Input Module Dual-input redundant power supply
60R/CHA02-00-0 3U Chassis Panel Houses and powers multiple 60R modules

Popular Bently Nevada Models

Model Number Description Application Focus
3500/42M Proximitor Monitoring Module Multi-channel vibration/position monitoring
3500/40M Vibration Monitor Machine protection with four-channel input
3500/22M Transient Data Interface Module High-resolution transient data acquisition
330104-00-20-10-02-05 Proximity Probe Precision shaft vibration measurement
330180-51-05 Velocity Sensor Seismic and structural vibration detection
330130-040-00 Extension Cable Low-noise signal transmission for probes

Bently Nevada 60R/RLY01-00-0 Electro-Mech Relay Module

Company Information
E-mail [email protected]
Mobile +8613666033393
Whatsapp +8613666033393
WeChat 13666033393
Add Room 1004, No. 62 Xiangxiu Li, Siming District, Xiamen City, Fujian Province, China

Excellent PLC Co., Ltd. has a large number of brand new and original PLC and DCS spare parts, with more than 60 cooperative countries. All products are guaranteed for 1 year and delivered to you by high-quality express. We are committed to using the best products and the most favorable prices to meet the needs and friendship of our customers. We have won the trust of thousands of customers, including these excellent customers.

As for the delivery time, when we receive your order requirements, we will arrange for warehouse personnel to test and verify the products. After you place the order, we will send it to you within 24 hours.

Click to rate this post!
[Total: 0 Average: 0]

Prev:

Next:

Leave a message