Product Introduction
The GE IC200ALG264L is a high-performance analog input module designed for use within the GE Fanuc VersaMax™ series of programmable logic controllers (PLCs). This module offers eight isolated channels of analog current input, providing exceptional flexibility and reliable signal acquisition for industrial automation systems. Each channel accepts current input in the 4-20 mA range, making it suitable for a wide variety of industrial sensors and transducers.
This module is engineered to provide precise, noise-resistant analog signal measurement, suitable for both demanding process control applications and general industrial use. With a compact form factor and simple integration into VersaMax I/O racks, it contributes to efficient and modular system design.
Product Specifications
| Parameter | Details |
|---|---|
| Manufacturer | GE Fanuc |
| Model Number | IC200ALG264L |
| Product Type | Analog Input Module |
| Number of Channels | 8 Analog Current Input Channels |
| Input Signal Type | 4–20 mA Current Input |
| Isolation | Channel-to-channel and channel-to-backplane isolation |
| Input Resolution | 15 bits + sign (16 bits total) |
| Input Impedance | 250 ohms (internal resistor per channel) |
| Update Rate | 2.5 ms per channel |
| Accuracy | ±0.15% of full scale at 25°C |
| Diagnostics | Open wire detection, fault diagnostics |
| Power Requirements | 75 mA from +5V, 80 mA from +24V (nominal) |
| Operating Temperature | -20°C to +60°C |
| Storage Temperature | -40°C to +85°C |
| Humidity | 5% to 95% non-condensing |
| Mounting Type | DIN rail or panel mount via VersaMax rack |
| Dimensions (W x H x D) | 110 x 66.8 x 50 mm |
| Weight | 0.222 kg |
| Module Type | Isolated Analog Input |
| Compatibility | VersaMax Modular I/O, CPU units, and NIU |
| Certifications | CE, UL, cUL, Class I Div 2 (hazardous locations) |
Applications
The IC200ALG264L module finds wide application across industrial automation and control sectors, including:
-
Manufacturing Plants – For monitoring pressure, flow, temperature, and other analog process signals.
-
Oil & Gas – Used for acquiring signals from transmitters in remote or hazardous environments.
-
Water and Wastewater Management – Suitable for monitoring flow meters, level transmitters, and environmental sensors.
-
HVAC Systems – Accurate control of air handling units and climate monitoring.
-
Food & Beverage Automation – For continuous process control and quality assurance.
-
Power Plants and Utilities – Real-time data collection from field instrumentation.
Product Advantages
-
High Channel Density: Offers 8 independent current input channels, reducing hardware footprint.
-
Robust Isolation: Channel-to-channel isolation improves reliability and protects other devices from electrical faults.
-
Accurate Signal Conversion: 16-bit resolution ensures precise measurement of analog inputs.
-
Reliable Diagnostics: Built-in diagnostic functions help quickly identify issues, minimizing downtime.
-
Ease of Integration: Seamlessly integrates with GE Fanuc VersaMax systems, simplifying configuration and installation.
-
Space-Saving Design: Compact and modular design suited for panel-mounted applications.
-
Certified for Hazardous Locations: Safe for use in Class I Division 2 environments, supporting a wide range of industrial settings.
Frequently Asked Questions (FAQ)
-
What type of signals can the IC200ALG264L accept?
The module is designed to accept 4–20 mA current input signals on each of its 8 channels. -
Is this module compatible with all VersaMax PLCs?
Yes, it is fully compatible with VersaMax CPUs and Network Interface Units (NIUs). -
Does the IC200ALG264L support channel-to-channel isolation?
Yes, each input channel is isolated from the others and from the backplane. -
Can this module detect open circuit conditions?
Yes, it includes open wire detection diagnostics for all input channels. -
What is the input impedance of this analog module?
Each channel has an input impedance of 250 ohms. -
Is configuration software needed to set up the module?
Yes, configuration is typically done via GE Proficy Machine Edition or other VersaMax-compatible tools. -
What kind of mounting does the IC200ALG264L support?
It can be mounted on a DIN rail or panel via the VersaMax I/O carrier. -
Does the module require external power?
It requires +5V and +24V power from the backplane, not from external wiring. -
How accurate is this module under normal conditions?
It has a typical accuracy of ±0.15% full scale at 25°C. -
Is the module suitable for outdoor or hazardous environments?
Yes, it is certified for Class I Div 2 hazardous environments and can withstand industrial temperature ranges.
Related Models (Same Series or Functionality)
| Model | Description | Input Type | Channels | Mounting |
|---|---|---|---|---|
| IC200ALG230 | Analog Voltage Input Module | 0-10V | 8 | VersaMax |
| IC200ALG260 | Analog Current Input Module | 4–20 mA | 4 | VersaMax |
| IC200ALG266 | High-Density Analog Current Input | 16 x 4–20 mA | 16 | VersaMax |
| IC200ALG320 | Analog Voltage Output Module | 0-10V | 4 | VersaMax |
| IC200ALG322 | Analog Current Output Module | 4–20 mA | 4 | VersaMax |
| IC200MDL650 | Mixed Input/Output Module | DI/DO | 16/16 | VersaMax |
Popular GE Fanuc Models (Same Brand)
| Model | Description | Function | Channels | Type |
|---|---|---|---|---|
| IC695CPU320 | PACSystems RX3i CPU Module | CPU | N/A | Controller |
| IC693MDL645 | Digital Input Module | 24VDC Input | 16 | Input |
| IC694ALG442 | Analog Output Module | Voltage/Current Output | 4 | Output |
| IC200CHS022 | VersaMax I/O Carrier | I/O Base | N/A | Mounting Base |
| IC695PSA040 | Power Supply Module | 40W, Universal Input | N/A | Power Supply |
| IC693PWR321 | Standard Power Supply | 120/240VAC, 125VDC | N/A | Power Supply |
Excellent PLC