Product Introduction
The HIMA F2301 98 1230102 NOT Gate With New Module is a critical component for safety and control systems, specifically designed to function as a NOT gate within a modular control architecture. This device is part of HIMA’s F20 series and has been enhanced to provide better integration capabilities and more robust performance in industrial automation and safety-critical systems.
The NOT gate function is crucial in various process control applications where the logical inverse of an input is required for ensuring safe and reliable operations. By using the F2301, engineers can implement fail-safe systems with advanced diagnostics and continuous monitoring capabilities.
Product Specifications
Below is a detailed table of the key specifications for the HIMA F2301 98 1230102 NOT Gate With New Module:
Specification | Details |
---|---|
Model | F2301 98 1230102 |
Function | NOT Gate (Inverter) |
Module Type | New Module |
Input Voltage | 24 VDC |
Output Type | Digital Output (Inverse Logic) |
Output Voltage | 24 VDC |
Input Resistance | 4.7 kΩ |
Relay Contact Rating | 2 A @ 30 VDC |
Dimensions | 150 x 120 mm |
Weight | 0.5 kg |
Temperature Range | -20°C to 60°C |
Mounting Type | DIN Rail Mount |
Diagnostic Features | Built-in diagnostic LEDs and fault detection |
Compliance | SIL 3 Certified |
Applications
The HIMA F2301 98 1230102 NOT Gate module is designed for use in safety-critical applications, particularly in industries such as:
- Industrial Automation: For controlling input signals and ensuring logic integrity in control systems.
- Process Control: In systems requiring fail-safe operations, like manufacturing plants or chemical processing.
- Safety Systems: Essential in safety-critical systems where logic inversion is necessary for emergency shutdown or other protective measures.
- Energy Management: Used in power plants or energy grids for safe operation, data integrity, and fault management.
Advantages
- Enhanced Safety: Certified to SIL 3 standards, this module ensures a high level of functional safety for critical processes.
- High Reliability: Built for demanding industrial environments, offering consistent performance even under harsh conditions.
- Ease of Integration: The module integrates easily with existing control systems, minimizing downtime and setup costs.
- Comprehensive Diagnostics: Equipped with built-in diagnostic features to monitor the health of the system and alert operators to any faults.
- Compact Design: Despite its powerful capabilities, the module has a compact size that can be easily mounted in confined spaces.
- Temperature Tolerance: Operating in temperatures from -20°C to 60°C, making it versatile for a range of environments.
- Cost-Effective: Offers a cost-efficient solution for implementing a NOT gate function without the need for additional complex components.
Latest News Titles
- “HIMA Expands Product Range with Advanced Safety Modules”
- “F2301 NOT Gate Module: A Key Element for Reliable Industrial Automation”
- “New HIMA F2301 Modules Now Available with Enhanced Diagnostic Capabilities”
- “HIMA F2301 Enhances Safety and Reliability in Process Control Systems”
- “HIMA’s New NOT Gate Module to Improve Fault Detection in Hazardous Areas”
- “F2301 NOT Gate Module: A Robust Solution for High-Security Systems”
- “HIMA Introduces Modular Safety Solutions for Complex Industrial Systems”
- “Safe, Reliable, and Compact: The New HIMA F2301 NOT Gate”
- “Ensuring System Integrity with the HIMA F2301 Module”
- “HIMA F2301 – The Trusted Choice for SIL 3 Compliance in Safety Systems”
Frequently Asked Questions (FAQ)
-
What is the function of the HIMA F2301 98 1230102 module?
- It serves as a NOT gate, providing an inverted output for control systems that require this logical operation.
-
What safety certifications does the F2301 module have?
- It is certified to SIL 3, making it suitable for high-integrity safety systems.
-
What is the input voltage requirement for this module?
- The input voltage is 24 VDC.
-
Can the F2301 module be used in hazardous environments?
- Yes, it is designed for industrial environments, including those with potentially hazardous conditions.
-
What is the temperature range in which the F2301 module operates?
- The operating temperature range is from -20°C to 60°C.
-
Is the F2301 compatible with other HIMA modules?
- Yes, it is fully compatible with other modules in the HIMA F20 series.
-
How is the F2301 mounted?
- The module is mounted using a DIN rail, which simplifies installation in standard control cabinets.
-
What kind of diagnostic features are included with the F2301?
- It features diagnostic LEDs and fault detection capabilities for better system health monitoring.
-
What is the weight of the F2301 module?
- The module weighs 0.5 kg.
-
Is there any additional software required to use the F2301 module?
- No additional software is needed for basic operation, but HIMA’s configuration tools can be used for advanced setups.
Related Models from the Same Series or Brand
Model | Description | Specifications |
---|---|---|
HIMA F2302 | AND Gate Module | Input Voltage: 24 VDC, Weight: 320 g, SIL 3 Certified |
HIMA F2303 | XOR Gate Module | Input Voltage: 24 VDC, Dimensions: 130 mm x 80 mm x 25 mm |
HIMA F2304 | NOR Gate Module | SIL 3 Certified, Output Voltage: 24 VDC, Temperature: -20°C to 60°C |
HIMA F2401 | Relay Output Module | Relay Rating: 2 A, Temperature Range: -20°C to 70°C |
HIMA F2501 | Analog Input Module | Input Voltage: 24 VDC, Weight: 400 g, SIL 3 Certified |
HIMA F2502 | Digital Input Module | Input Voltage: 24 VDC, Dimensions: 125 mm x 75 mm x 20 mm |
HIMA F2801 | Digital Output Module | Output Type: Digital, SIL 3 Certified, Weight: 350 g |
HIMA F2101 | Logic AND Gate with Enhanced Diagnostics | SIL 3 Certified, Input Voltage: 24 VDC, Diagnostic Features |
HIMA F2201 | OR Gate Module | Output Voltage: 24 VDC, SIL 3 Certified, Compact Design |
HIMA F3001 | Safety Controller Module | SIL 3 Certified, Supports Multiple Input Types |
Popular Models from the HIMA Brand
Model | Description | Key Features |
---|---|---|
HIMA F3231 | High-Speed Safety Controller Module | SIL 3 Certified, Fast Processing Speed |
HIMA F3631 | Modular Safety System Controller | Flexible Configuration, SIL 3 Certified |
HIMA F2100 | Safety I/O Module | SIL 3 Certified, Compact, Easy Integration |
HIMA F2140 | Digital Output Module | Input Voltage: 24 VDC, Compact Design |
HIMA F2110 | Analog Output Module | Supports Multiple Output Formats |
HIMA F2321 | Dual Relay Output Module | Dual Output, SIL 3 Certified |
HIMA F2020 | High-Integrity Safety System Controller | Supports Redundant Configurations, SIL 3 Certified |
HIMA F1000 | Basic Safety Module | Entry-Level Solution, SIL 2 Certification |
HIMA F2500 | Safety I/O Expansion Module | Supports Large Systems, SIL 3 Certified |
HIMA F3000 | Full-Featured Safety Control System | Advanced Diagnostics, SIL 3 Certified |