Product Introduction
The HIMA F3003 is a robust, high-performance safety relay from HIMA’s safety system series. Designed for use in critical applications, the F3003 ensures the protection and operational integrity of various industrial systems, including those in the chemical, oil and gas, and manufacturing industries. It plays a central role in safeguarding personnel, equipment, and processes from hazards by detecting faults and initiating appropriate safety responses.
The HIMA F3003 features a modular design and can be integrated seamlessly into complex safety networks. Its flexibility and reliability make it an ideal solution for applications requiring high levels of safety integrity, such as process automation systems, emergency shutdown systems, and fire and gas detection systems.
Product Specifications
Specification | Value |
---|---|
Product Type | Safety Relay |
Voltage | 24 V DC |
Input Type | Digital, Analog |
Output Type | Relay, Solid State |
Relay Type | 2-Channel |
Mounting Type | DIN Rail |
Dimensions | 130 x 120 x 50 mm |
Weight | 0.5 kg |
Temperature Range | -20°C to +60°C |
Power Consumption | < 10 W |
Certification | IEC 61508 SIL 3, ATEX |
Ingress Protection | IP20 |
Applications
The HIMA F3003 safety relay is widely used in industries where safety and reliability are paramount. Its applications include, but are not limited to:
-
Process Control Systems: To monitor and protect critical equipment and processes in industries like petrochemical, pharmaceutical, and food processing.
-
Emergency Shutdown Systems (ESD): In high-risk environments to instantly shut down hazardous operations in case of emergencies.
-
Fire & Gas Detection Systems: To identify hazardous levels of gas or fire, initiating shutdown or alarm responses to prevent accidents.
-
Safety Instrumented Systems (SIS): Used to ensure that systems operate within their safe limits by activating alarms or shutdowns when necessary.
Advantages
-
High Reliability: Meets the highest safety standards with a SIL 3 (Safety Integrity Level) certification, ensuring dependable operation in safety-critical environments.
-
Modular and Scalable: Offers flexible configurations that can be tailored to specific system requirements.
-
Easy Integration: Compatible with various control systems, enabling seamless integration into existing industrial automation setups.
-
Wide Temperature Range: Operates reliably in diverse environmental conditions, from -20°C to +60°C, making it suitable for harsh industrial environments.
-
Low Power Consumption: Designed to be energy-efficient, reducing operational costs while maintaining top-notch performance.
-
Compact Design: Its compact size allows for space-saving installation in control panels or safety control systems.
FAQ
1. What is the purpose of the HIMA F3003 safety relay?
The HIMA F3003 is designed to provide fail-safe control and ensure the safety of critical industrial processes. It monitors input signals and triggers a safe response in the event of a fault or hazard.
2. What industries can benefit from the HIMA F3003?
The HIMA F3003 is widely used in industries like oil and gas, chemical processing, pharmaceuticals, and food manufacturing, where high levels of safety are required.
3. What are the key features of the HIMA F3003?
Key features include high reliability with SIL 3 certification, flexible modular design, wide operational temperature range, and compatibility with various safety control systems.
4. How is the HIMA F3003 mounted?
The F3003 can be easily mounted on a DIN rail, making installation straightforward in most industrial control cabinets.
5. Can the HIMA F3003 be integrated with existing safety systems?
Yes, it is designed to integrate seamlessly with existing safety instrumented systems and can be used in conjunction with other HIMA products.
6. What certifications does the HIMA F3003 have?
The F3003 meets IEC 61508 SIL 3 standards for functional safety and is ATEX certified for use in explosive atmospheres.
7. What is the temperature range for the HIMA F3003?
The device operates within a temperature range of -20°C to +60°C, allowing it to function in both cold and hot environments.
8. What is the weight of the HIMA F3003 safety relay?
The HIMA F3003 weighs 0.5 kg, making it lightweight for easy handling and installation.
9. Can the F3003 be used in hazardous environments?
Yes, the F3003 has an ATEX certification, making it suitable for use in hazardous areas with explosive gases or dust.
10. What kind of outputs does the HIMA F3003 have?
The F3003 provides both relay and solid-state outputs, giving users flexibility in how they integrate the safety relay into their systems.
Recommendations for 6 Same-Series or Related Models
Model | Description | Key Features |
---|---|---|
HIMA F3002 | Basic Safety Relay | SIL 3, Compact, Reliable |
HIMA F3004 | Advanced Safety Relay with More Channels | Multiple Inputs and Outputs, Flexible Design |
HIMA F5003 | Safety Relay for Fire & Gas Detection | Specially designed for high-risk applications |
HIMA F3001 | Standard Safety Relay | Compact, Easy to Integrate |
HIMA F2003 | Cost-Effective Safety Relay | Low-cost option with SIL 2 certification |
HIMA F4003 | Multi-function Safety Relay | Provides both safety and control functions |
Recommendations for 6 Popular Models from the Same Brand (HIMA)
Model | Description | Key Features |
---|---|---|
HIMA HIMAX | Safety and Control System | High integration with advanced monitoring |
HIMA F3232 | Safety Control for Process Industry | Robust and reliable for process automation |
HIMA SIB2000 | Safety System Interface | Modular design for scalable safety systems |
HIMA F62S | Functional Safety Monitoring | SIL 3 Certified, versatile in complex processes |
HIMA F3300 | Enhanced Safety Relay | Offers higher fault tolerance and safety features |
HIMA S7000 | Advanced Safety Management System | Comprehensive safety and control management |