Product Introduction
The HIMA F6251 is a high-reliability safety-related limit monitor designed for critical industrial applications requiring precise monitoring of process parameters. Manufactured by HIMA, a leading German company specializing in safety automation solutions, the F6251 ensures rapid detection and response to deviations in process limits, thereby enhancing plant safety and compliance with international safety standards. It is widely utilized in industries such as oil & gas, chemical processing, and power generation, where safety is paramount.
Product Specifications
Parameter | Description |
---|---|
Model Number | F6251 |
Part Number | 984625102 |
Manufacturer | HIMA |
Product Type | Safety-Related Limit Monitor |
Input Signal Type | Analog (0–10V, 4–20mA) / Digital |
Number of Inputs | 2 redundant channels |
Response Time | < 10 ms |
Operating Voltage | 24 VDC nominal (19.2V to 30V range) |
Power Consumption | ≤ 5W |
Operating Temperature | -25°C to +70°C |
Storage Temperature | -40°C to +85°C |
Relative Humidity | 5% to 95% non-condensing |
Safety Integrity Level (SIL) | SIL 3 per IEC 61508 |
Mounting Type | DIN rail mounting |
Dimensions (H x W x D) | 120 x 80 x 40 mm |
Weight | 0.159 kg |
Communication Interface | HIMA proprietary system bus |
Protection Class | IP20 (for control cabinet installation) |
Certifications | CE, ATEX (Zone 2), TÜV Rheinland (Functional Safety), EN 50156-2 compliant |
Product Applications
-
Process Limit Monitoring: Ensures that critical process parameters remain within predefined safety limits, triggering alarms or shutdowns upon deviations.
-
Emergency Shutdown Systems (ESD): Integrates into ESD systems to provide rapid response to hazardous conditions, safeguarding personnel and equipment.
-
Redundant Safety Architectures: Supports dual-channel configurations for high-availability systems requiring redundancy.
-
Industrial Automation: Applicable in various industries, including oil & gas, chemical processing, and power generation, for enhancing operational safety.
Product Advantages
-
High Reliability: Designed for continuous operation in demanding industrial environments, ensuring consistent performance.
-
Rapid Response: Fast detection and reaction to process deviations (<10 ms response time), minimizing potential hazards.
-
Compact Design: Slim profile (20 mm width) facilitates easy integration into existing control panels without requiring significant space.
-
Robust Construction: Built to withstand harsh conditions, including wide temperature ranges and high humidity levels.
-
Compliance with Safety Standards: Certified to SIL 3 per IEC 61508, ensuring adherence to international safety requirements.
-
Ease of Integration: Compatible with HIMA’s proprietary system bus, allowing seamless communication within HIMA safety systems.
Frequently Asked Questions (FAQ)
-
What is the primary function of the HIMA F6251?
The F6251 is designed to monitor process parameters and ensure they remain within predefined safety limits, triggering appropriate responses when deviations occur. -
What types of input signals does the F6251 accept?
It accepts both analog (0–10V, 4–20mA) and digital signals, providing flexibility in monitoring various process variables. -
Is the F6251 suitable for use in hazardous areas?
Yes, it is certified for use in ATEX Zone 2 hazardous areas, making it suitable for environments with explosive atmospheres. -
What is the Safety Integrity Level (SIL) rating of the F6251?
The F6251 is certified to SIL 3 according to IEC 61508 standards, indicating a high level of safety performance. -
Can the F6251 be integrated into existing HIMA safety systems?
Yes, it features a proprietary system bus interface for seamless integration with other HIMA components. -
What is the response time of the F6251?
The module has a rapid response time of less than 10 milliseconds, ensuring prompt action upon detecting parameter deviations. -
What are the mounting options for the F6251?
It is designed for DIN rail mounting, facilitating easy installation within control cabinets. -
What environmental conditions can the F6251 withstand?
The module operates within a temperature range of -25°C to +70°C and can be stored between -40°C and +85°C, with humidity levels from 5% to 95% non-condensing. -
Does the F6251 support redundant configurations?
Yes, it features two redundant input channels, enhancing system reliability through redundancy. -
What certifications does the F6251 hold?
The module is certified by TÜV Rheinland for functional safety and complies with CE, ATEX (Zone 2), and EN 50156-2 standards.
Related Models from the Same Series or Functionality
Model | Description | Input Type | SIL Rating | Dimensions (mm) | Weight (g) |
---|---|---|---|---|---|
F3331 | 8-Channel Safety-Related Output Module | Digital Outputs | SIL 3 | 119 x 89 x 45 | 113 |
F3334 | Safety-Related Controller with Counters and Analog Inputs | Analog/Digital Inputs | SIL 3 | 100 x 50 x 25 | 150 |
F3316 | Safety Systems Input Module with Dual-CPU Architecture | Digital Inputs | SIL 3 | 100 x 50 x 20 | 100 |
F3324 | High-Performance Safety Relay for ESD Systems | Digital Inputs | SIL 3 | 22.5 x 99 x 114 | 150 |
F30 | Compact Safety Controller for Industrial Applications | Digital I/O | SIL 3 | 51 x 127 x 51 | 500 |
62100 | 2-Channel Limit Monitor for Analog Signals | Analog Inputs | SIL 4 | 45 x 100 x 22.5 | 1000 |
Popular Models from HIMA (Same Brand)
Model | Description | Function | SIL Rating | Dimensions (mm) | Weight (g) |
---|---|---|---|---|---|
F8627X | Safety Controller with Modular Design and Ethernet Communication | Safety Controller | SIL 3 | 145 x 100 x 62 | 450 |
F8652X | High-Performance Safety Controller for Hazardous Environments | Safety Controller | SIL 3/4 | 100 x 50 x 25 | 150 |
F30 | Compact Safety Controller for Industrial Applications | Safety Controller | SIL 3 | 51 x 127 x 51 | 500 |
F3331 | 8-Channel Safety-Related Output Module | Output Module | SIL 3 | 119 x 89 x 45 | 113 |
F3334 | Safety-Related Controller with Counters and Analog Inputs | Controller Module | SIL 3 | 100 x 50 x 25 | 150 |
F3316 | Safety Systems Input Module with Dual-CPU Architecture | Input Module | SIL 3 | 100 x 50 x 20 | 100 |