Product Introduction
The Honeywell 10008/2/U Communication Module is a key component of the FSC (Fail Safe Controller) system, built specifically for high-reliability industrial control and safety environments. Designed to serve as a gateway for redundant, high-speed data communication, the 10008/2/U module acts as a central processor for I/O modules and ensures deterministic exchange between the safety logic solver and supervisory control networks.
This module operates as a redundant Universal Processor, managing communication between multiple I/O modules, coordinating safety functions, and maintaining synchronization across the control system. With a focus on system reliability, diagnostics, and integration readiness, the 10008/2/U is an essential piece in any mission-critical safety infrastructure.
Product Specifications
Parameter | Details |
---|---|
Model Number | 10008/2/U |
Manufacturer | Honeywell |
Module Type | Communication Processor Module |
System Compatibility | FSC (Fail Safe Controller) |
Communication Ports | Dual Redundant Backplane Links, Serial Ports (Variant Dependent) |
Processor | High-Speed Safety-Certified Embedded Processor |
Protocol Support | Honeywell Safety Bus, Peer-to-Peer FSC, Redundant Comms |
Internal Memory | Embedded SRAM / Flash for Firmware and Runtime |
Functionality | Manages I/O module logic, peer-to-peer sync, diagnostics |
Redundancy Support | Yes – Full Processor Redundancy |
Power Supply | 24 VDC via system backplane |
Power Consumption | ≤ 7 W |
Operating Temperature | 0°C to 60°C |
Storage Temperature | -40°C to +85°C |
Humidity | 5% – 95% non-condensing |
Mounting | Slot-in (Rack-mounted into FSC Chassis) |
Dimensions (H × W × D) | 38 x 127 x 178 mm |
Weight | 0.45 kg |
Certifications | CE, UL, CSA, ATEX Zone 2, SIL 3 |
Product Applications
The Honeywell 10008/2/U is used extensively in systems requiring certified fail-safe operation, robust control coordination, and secure communication. It is applied in:
-
Petrochemical Plants – As a processor for emergency shutdown systems with multi-zone coordination.
-
Offshore Oil Platforms – For redundant safety and communication among field control stations.
-
Natural Gas Facilities – Managing distributed safety and logic controllers across pipelines.
-
Power Generation Stations – Acting as the central controller for I/O safety functions.
-
Pharmaceutical Manufacturing – Integrated into validated safety systems for cleanroom operations.
-
Mining and Mineral Processing – Supporting hazardous-area safe control and data aggregation.
Product Advantages
-
Centralized Logic Execution: Controls and processes I/O module logic for fast safety response.
-
Redundant Processing Capability: Ensures fault-tolerant operation with automatic switchover.
-
Real-Time Diagnostics: Internal monitoring of CPU, memory, and comm links for predictive maintenance.
-
Peer-to-Peer Synchronization: Maintains continuous alignment across distributed safety modules.
-
ATEX and SIL 3 Certified: Ready for deployment in safety- and explosion-critical environments.
-
Efficient Communication Backbone: Handles complex data loads between I/O and system controller.
-
Compact and Modular: Easy slot-in design reduces installation time and footprint.
-
Power Stability: Low power draw ensures minimal system impact while delivering maximum performance.
-
Lifecycle Longevity: Designed for extended operational life in 24/7 safety systems.
-
Honeywell Ecosystem Integration: Seamlessly communicates with FSC and Experion/TDC networks.
Frequently Asked Questions (FAQ)
-
What role does the 10008/2/U module play within the FSC system?
It acts as the communication and logic processor, handling I/O coordination and network synchronization. -
Is redundancy supported for this module?
Yes, the module is fully redundancy-capable and can be deployed in a dual-redundant configuration for fault-tolerant operation. -
How does the module communicate with other devices?
Via redundant backplane channels and Honeywell safety bus, ensuring secure and high-speed data transfer. -
Is configuration required before deployment?
Yes, it must be configured using Honeywell’s FSC engineering tools for proper functionality and network alignment. -
Can this module operate in hazardous areas?
Yes, it is ATEX Zone 2 certified and suitable for hazardous industrial environments. -
What happens in case of a module failure?
In redundant setups, the backup processor automatically takes over without system interruption. -
Does the module support software or firmware upgrades?
Yes, firmware updates can be applied through Honeywell’s secure update mechanisms. -
Can this module be used as a standalone processor?
No, it is designed to work as part of a larger FSC system and requires integration with I/O modules and system chassis. -
How is communication integrity ensured?
Through error-checking protocols, link redundancy, and real-time diagnostics within the FSC system. -
Is there any visual feedback for diagnostics?
Yes, the module includes LED indicators for status, communication, and error signaling.
Related Models (Same Series or Functionally Similar)
Model Number | Description | Key Function | System |
---|---|---|---|
10008/2/1 | I/O Communication Processor Module | Standard FSC logic coordination | Honeywell FSC |
10004/1/1 | Communication Interface Module | Network Communication | Honeywell FSC |
10004/I/F | Interface Gateway Module | Protocol Conversion / Redundancy | Honeywell FSC |
10005/1/1 | Protocol Conversion Module | Multi-protocol Communication | Honeywell FSC |
51401291-100 | Redundant Ethernet Interface Module | Network Fault Tolerance | Honeywell PKS/C300 |
51199929-100 | RS-232/485 Serial Communication Module | Legacy System Integration | Experion / FSC |
Popular Honeywell Models (Cross-Series and High-Demand Units)
Model Number | Description | Series | Function |
---|---|---|---|
CC-TDIL01 | 24V Digital Input Module | Experion C300 | Discrete Input Acquisition |
MC-PAIH03 | Analog Input Module (4-20mA) | TDC3000 | Analog Sensor Reading |
FC-TDIO11 | Dual Input/Output Module | FSC | Mixed DI/DO Signals |
CC-PCNT01 | Pulse Counter Module | Experion PKS | High-Speed Input Measurement |
TC-IAH061 | High Accuracy Analog Input | TDC3000 | Precision Process Input |
51198947-100 | Ethernet Communication Interface | TDC3000 / TPS | DCS Network Integration |