The Honeywell 2MLI-CPUS CPU Module is acentral processing unit (CPU) desHoneywell MasterLogic-200 series, this CPU module provides high-speed processing, real-time data execution, and advanced communication capabilities, making it ideal for complex control applications. The 2MLI-CPUS supports high-speed I/O operations, extensive networking features, and seamless integration with Honeywell’s distributed control systems (DCS) and SCADA environments.
Technical Specifications
Specification | Details |
---|---|
Processor | 32-bit high-performance industrial CPU |
Clock Speed | 166 MHz |
Memory (RAM) | 16 MB SDRAM |
Flash Memory | 8 MB for program storage |
Cycle Time | 0.08 µs per logical instruction |
Communication Ports | RS-232C, RS-485, Ethernet (10/100 Mbps) |
I/O Capacity | Supports up to 512 I/O points |
Expansion Slots | 2 module slots for communication or memory cards |
Redundancy Support | Yes, supports CPU redundancy |
Power Consumption | 5W |
Operating Temperature | -10°C to 60°C (14°F to 140°F) |
Storage Temperature | -40°C to 85°C (-40°F to 185°F) |
Humidity | 10% – 90% non-condensing |
Mounting | DIN rail or panel mounting |
Dimensions | 195 × 120 × 85 mm |
Weight | 0.099 kg |
Certifications | CE, UL, CSA, TÜV, IEC 61131-3 compliant |
Applications
The Honeywell 2MLI-CPUS CPU module is widely used in various industrial automation and control applications, including:
- Manufacturing Automation: Controls robotic arms, assembly lines, and material handling systems.
- Process Control: Used in chemical, pharmaceutical, and food processing plants for precise system regulation.
- Power Generation: Integrated in SCADA and DCS environments for turbine and generator control.
- Oil & Gas Industry: Manages drilling operations, pipeline control, and refinery automation.
- Water & Wastewater Treatment: Ensupump and valve operations.
- Building Management Systems: Used in HVAC control, lighting systems, and security automation.
Advantages
- High-Speed Processing: Ecycle time of 0.08 µs per instruction, ens
- Robust Communication Capabilities: Includes RS-232C, RS-485, and Ethernet ports for seamless integration with various network environments.
- Scalability: Supports 512 I/O points, making it suitable for both small-scale and large-scale industrial applications.
- Redundancy Support: Ensures system reliability with hot standby CPU redundancy for mission-critical operations.
- Energy Efficient: Consumes only 5W of power, making it an eco-friendly choice.
- Durable Design: Operates under extreme industrial conditions (-10°C to 60°C) with high resistance to vibration and electrical noise.
- Seamless Integration: Fully compatible with Honeywell Experion DCS and SCADA systems for centralized control and monitoring.
- Long-Term Reliability: Designed for continuous operation in industrial settings with minimal maintenance requirements.
Latest Industry News Headlines
- “Honeywell Enhances MasterLogic-200 Series with High-Speed Processing Upgrades”
- “New PLC Solutions: How the 2MLI-CPUS Module Improves Manufacturing Efficiency”
- “Honeywell Introduces Advanced CPU Redundancy for Industrial Automation”
- “How Honeywell’s 2MLI-CPUS is Revolutionizing Smart Factory Automation”
- “Energy-Efficient Control: The 2MLI-CPUS Module Reducing Operational Costs”
- “Honeywell’s MasterLogic Series Expands with Improved Cybersecurity Features”
- “Adapting PLC Technology for Industry 4.0: The Role of 2MLI-CPUS”
- “New Benchmarks in PLC Performance: Honeywell’s Latest CPU Module Explained”
FAQ
1. What is the primary function of the 2MLI-CPUS CPU module?
The Honeywell 2MLI-CPUS serves as the central processor for MasterLogic-200 PLC systems, managing real-time automation and control logic for industrial applications.
2. Does this module support redundancy?
Yes, it supports hot standby redundancy, ensuring system reliability in critical applications.
3. How many I/O points does it support?
The 2MLI-CPUS supports up to 512 I/O points, making it highly scalable.
4. What is the power consumption of the module?
The Honeywell 2MLI-CPUS has a low power consumption of 5W, making it energy-efficient.
5. Can this CPU module communicate with SCADA systems?
Yes, it integrates seamlessly with Honeywell Experion SCADA and third-party SCADA systems via Ethernet and serial communication protocols.
6. What is the operating temperature range?
The module operates reliably within -10°C to 60°C (14°F to 140°F).
7. What type of industrial applications is this module used for?
It is used in manufacturing automation, process control, energy management, and building automation systems.
8. What are the available communication ports?
It includes RS-232C, RS-485, and Ethernet (10/100 Mbps) communication ports.
9. What is the CPU clock speed?
The 2MLI-CPUS runs at 166 MHz, ensuring fast processing times.
10. Is this module compatible with other Honeywell systems?
Yes, it is fully compatible with Honeywell MasterLogic-200, Experion DCS, and SCADA platforms.
Related Models in the Honeywell MasterLogic-200 Series
Model Number | Description |
---|---|
2MLI-CPUM | Medium-Performance CPU Module |
2MLI-CPUH | High-Performance CPU Module |
2MLF-DI16A | 16-Channel Digital Input Module |
2MLF-DO16A | 16-Channel Digital Output Module |
2MLF-AD4A | 4-Channel Analog Input Module |
2MLF-DA4A | 4-Channel Analog Output Module |
2MLF-COM4A | 4-Channel Communication Module |
2MLF-HSC2A | 2-Channel High-Speed Counter Module |
Popular Honeywell Modules
Model Number | Description |
---|---|
CC-PAIX02 | Advanced Analog Input Module for C300 Controllers |
CC-PDIL01 | Digital Input Module for C300 Systems |
CC-PDOB01 | Digital Output Module for Honeywell C300 |
FC-SDOL-0424 | Safety Digital Output Module |
CC-PUIO01 | Universal I/O Module |
MC-PAIH03 | Advanced Process Analog Input Module |
MC-PDIY22 | Redundant Digital Input Module |