Company Information | ||||||||
[email protected] | ||||||||
Mobile | +8613666033393 | |||||||
+8613666033393 | ||||||||
13666033393 | ||||||||
Add | Room 1004, No. 62 Xiangxiu Li, Siming District, Xiamen City, Fujian Province, China |
Product Introduction
The Honeywell 621-0022 is a high-performance Isolated Analog Input Module designed for Honeywell’s TDC 2000/3000 and PlantScape control systems. As part of Honeywell’s robust control system architecture, this module plays a crucial role in process automation, offering accurate and noise-resistant analog signal acquisition.
The 621-0022 module ensures safe and precise transmission of analog signals from field devices, such as pressure transmitters, temperature sensors, and flow meters, into the central control system. Its isolation capability prevents electrical interference, ensuring the integrity and reliability of data acquisition in critical industrial environments.
This module supports multiple analog signal types (e.g., 4–20 mA, 0–10 V) and is optimized for use in mission-critical applications such as chemical plants, oil & gas facilities, and energy production systems.
Technical Specifications
Parameter | Description |
---|---|
Model Number | 621-0022 |
Type | Isolated Analog Input Module |
Signal Type | Analog (e.g., 4–20 mA, 0–10 V) |
Number of Channels | 8 analog input channels |
Input Isolation | Optical/electrical isolation per channel |
Resolution | 12-bit or better (depends on system config) |
Input Range | Configurable, typically ±10V or 0–20mA |
Accuracy | ±0.1% of full scale |
Power Consumption | Approx. 3W |
Diagnostics | Internal diagnostics and fault detection |
Operating Temperature Range | 0°C to 60°C (32°F to 140°F) |
Storage Temperature Range | -40°C to 85°C (-40°F to 185°F) |
Humidity | 5% to 95% RH, non-condensing |
Mounting | DIN-rail or backplane slot |
Dimensions (W x H x D) | 33 x 274 x 171 mm |
Weight | 0.68 kg |
Compliance | CE, RoHS, ISA, UL certified |
Applications
The Honeywell 621-0022 module is engineered for critical industrial and manufacturing processes where reliable analog signal acquisition is required. Common application scenarios include:
-
Chemical and Petrochemical Plants
Reliable measurement of process variables like flow, temperature, and pressure. -
Oil and Gas Industry
Data acquisition from field instrumentation in upstream and downstream operations. -
Power Generation Plants
Monitoring of analog parameters in turbines, boilers, and generators. -
Water and Wastewater Management
Measuring levels, flow rates, and water quality indicators. -
Pharmaceutical Manufacturing
Accurate and isolated signal acquisition in cleanroom environments. -
Food & Beverage Processing
Monitoring temperature and pressure during critical process stages.
Key Advantages
-
Electrical Isolation
Each channel is isolated to eliminate ground loops and reduce noise, ensuring accurate readings. -
High Reliability
Designed for demanding industrial environments with robust diagnostics and fault detection. -
Flexible Signal Support
Compatible with various analog signals (voltage and current), supporting diverse sensor types. -
Easy Integration
Seamless compatibility with Honeywell DCS systems like TDC 2000, TDC 3000, and PlantScape. -
Compact Design
Small footprint allows for efficient installation in tight cabinet spaces. -
Field-Proven Performance
Widely adopted in global industrial automation installations with proven long-term reliability.
Frequently Asked Questions (FAQ)
-
What signal types does the 621-0022 support?
It supports both voltage (e.g., 0–10V) and current (e.g., 4–20mA) analog input signals. -
Is each input channel isolated?
Yes, each analog input channel features electrical isolation to prevent ground loops and noise. -
Can the 621-0022 be used in hazardous areas?
It should be used with proper intrinsic safety barriers or certified enclosures for hazardous zones. -
What Honeywell systems are compatible with this module?
It integrates seamlessly with Honeywell’s TDC 2000, TDC 3000, and PlantScape DCS platforms. -
Does it have onboard diagnostics?
Yes, the module includes fault detection and internal diagnostics to support maintenance. -
What is the typical accuracy of this module?
It offers a typical accuracy of ±0.1% of full scale. -
How many channels does it provide?
The 621-0022 provides 8 isolated analog input channels. -
What installation options are available?
It can be mounted via DIN rail or inserted into a backplane slot. -
Is calibration required for each channel?
Factory calibration is provided, but periodic calibration may be required depending on process needs. -
What kind of isolation is used?
Typically, optical or transformer-based isolation techniques are used to ensure signal integrity.
Related Models (Same Series or Similar Functionality)
Model | Description | Channels | Signal Type |
---|---|---|---|
621-0021 | Analog Input Module, Non-Isolated | 8 | Voltage/Current |
621-0023 | Isolated Analog Output Module | 8 | Voltage/Current |
621-0016 | Digital Input Module | 16 | Binary |
621-0017 | Digital Output Module | 16 | Relay/Transistor |
621-9932 | 32-Channel Analog Multiplexer Module | 32 | Analog Switching |
620-0081 | Remote I/O Communication Interface | – | Communication Module |
Popular Honeywell Models (Across Product Lines)
Model | Description | Category | System Compatibility |
---|---|---|---|
HC900 Controller | Hybrid controller for process and logic control | Process Automation | Experion HS, Standalone |
C300 Controller | Advanced process controller | Distributed Control | Experion PKS |
51304493-150 | MC-TDODI12 Digital Output Module | Digital Output | TDC 3000, PlantScape |
51401583-100 | Analog Output Module (AO8) | Analog Output | Experion, TPS |
51400955-100 | Digital Input Module (DI8) | Digital Input | TPS |
FC-TSDI-1624 | Safety System Digital Input Module | Safety System Module | Safety Manager |