Product Introduction
The Honeywell 8C-POIL51 Digital Input Module is a reliable, high-performance industrial automation component designed to capture discrete digital signals from field devices such as switches, sensors, limit devices, and relay contacts. It is part of Honeywell’s robust C300 Process Control System, which forms the backbone of the Experion Process Knowledge System (PKS).
This module is engineered for critical environments where real-time digital signal acquisition is vital. It features 16 isolated input channels, ensuring each channel operates independently, reducing the risk of signal interference and improving noise immunity. Whether deployed in oil refineries, chemical processing plants, or manufacturing environments, the 8C-POIL51 provides dependable operation with diagnostics and system integration built-in.
Its compatibility with Honeywell’s IOTA (Input/Output Terminal Assembly) architecture ensures fast installation, modularity, and seamless integration into large-scale distributed control systems (DCS).
Product Specifications
| Parameter | Specification |
|---|---|
| Model Number | 8C-POIL51 |
| Manufacturer | Honeywell |
| Product Type | Digital Input Module |
| Input Channels | 16 isolated input channels |
| Input Voltage Range | 24V DC nominal |
| Input Type | Dry contact or NPN open collector |
| Isolation | Channel-to-channel and channel-to-ground |
| Input Impedance | Approx. 4.7 kΩ |
| Response Time | < 2 ms typical |
| Logic Levels | ON: ≥15 VDC, OFF: ≤5 VDC |
| Power Consumption | < 4 W |
| Status Indicators | Individual channel LEDs |
| Mounting | Pluggable into IOTA base |
| Diagnostics | Fault detection, open/short circuit |
| Operating Temperature | 0°C to +60°C |
| Storage Temperature | -40°C to +70°C |
| Humidity | 5% to 95%, non-condensing |
| Certifications | CE, UL, CSA |
| Dimensions (W x H x D) | 120 x 30 x 25 mm |
| Weight | 0.15 kg |
Product Applications
The 8C-POIL51 Digital Input Module is extensively deployed across a variety of industrial environments that require reliable digital signal acquisition and monitoring:
-
Oil & Gas Facilities: Monitoring valve positions, flow switches, emergency shutdown systems (ESD).
-
Petrochemical Plants: Capturing limit switch status and interlocks for process control.
-
Power Generation: Detecting breaker positions, status inputs from auxiliary systems.
-
Pharmaceutical Manufacturing: Monitoring sensor feedback in cleanroom automation.
-
Food & Beverage Processing: Capturing start/stop signals from distributed control buttons.
-
Water Treatment Plants: Integrating pump and level switch statuses into SCADA systems.
-
Mining Operations: Rugged environments requiring isolated input sensing for relays and contactors.
Product Advantages
-
High Channel Density: 16 fully isolated digital input channels in a compact footprint.
-
Noise Immunity: Channel isolation prevents ground loops and signal interference.
-
Diagnostics-Enabled: Integrated diagnostics identify faults rapidly, reducing downtime.
-
Wide Application Range: Suitable for dry contact or NPN open collector inputs.
-
Industrial-Grade Durability: Built to function under harsh environmental conditions.
-
Seamless Honeywell Integration: Optimized for Experion PKS and C300 control systems.
-
Fast Response: Millisecond-level response time for critical real-time applications.
-
Hot-Swappable: Modules can be replaced without shutting down the controller.
-
LED Indicators: Visual input status monitoring simplifies maintenance.
-
Regulatory Compliance: Meets CE, CSA, and UL industrial automation standards.
Frequently Asked Questions (FAQ)
-
What kind of devices can connect to the 8C-POIL51 module?
It supports dry contacts and open collector (NPN) digital signals from limit switches, pushbuttons, and relay contacts. -
How many inputs does the module support?
It has 16 individually isolated digital input channels. -
What voltage level is required for a valid “ON” signal?
A typical “ON” signal requires ≥15V DC. -
Can this module be hot-swapped while the system is running?
Yes, it is designed for safe hot-swapping to minimize system interruption. -
Is there individual LED indication for each input?
Yes, each channel has an LED that indicates its real-time status. -
Is channel-to-channel isolation provided?
Absolutely, each input channel is isolated from the others. -
Can the module detect open or short circuits?
Yes, onboard diagnostics include fault detection capabilities. -
What kind of system is it compatible with?
It is specifically designed for Honeywell C300 and Experion PKS systems. -
Is the module certified for industrial use?
Yes, it carries CE, CSA, and UL certifications. -
What is the typical response time?
It offers a fast response of less than 2 milliseconds.
Related Models from the Same Series
| Model Number | Description | Type | Features |
|---|---|---|---|
| 8C-IP0101 | Digital Input Module (Non-isolated) | Input | Lower-cost, non-isolated version |
| 8C-PAIH51 | Analog Input Module | Input | High-resolution analog input |
| 8C-PAOH51 | Analog Output Module | Output | Analog signal output with precision control |
| 8C-POZL51 | Digital Output Module (Non-isolated) | Output | 16-channel non-isolated output module |
| 8C-TDOD51 | High-Density Digital Output Module | Output | Compact design for space-saving setups |
| 8U-BXCB20-CN | Base Controller | Control | Central processing for I/O communication |
Popular Models from Honeywell (Same Brand)
| Model Number | Description | Type | Typical Use |
|---|---|---|---|
| CC-TDIL01 | High-Density Digital Input | Input | Compact high-channel input |
| CC-TDOB01 | High-Density Digital Output | Output | Digital output with diagnostics |
| CC-PAIH01 | Analog Input Module | Input | Measuring temperature, pressure, etc. |
| CC-PAOH01 | Analog Output Module | Output | Analog output for control loops |
| CC-PDIL01 | Digital Input Module | Input | Binary input for field signals |
| CC-PDOB01 | Digital Output Module | Output | Controls actuators and relays |
Excellent PLC