Product Introduction
The Honeywell CC-TAIN11 (51306515-175) is a high-performance I/O interface module developed for use within Honeywell’s Experion Process Knowledge System (PKS) and C300 controller architecture. As part of the ControlEdge and Experion platforms, this module plays a pivotal role in managing and integrating process data across distributed control systems (DCS). Engineered with Honeywell’s robust industrial standards, the CC-TAIN11 serves as an analog input interface, enabling reliable, scalable, and accurate signal acquisition from various field instruments. It is essential in mission-critical environments such as oil and gas, chemicals, refining, pharmaceuticals, and power generation, where precise monitoring and seamless system communication are imperative.
This module ensures continuous data integrity, high fault tolerance, and rapid diagnostics, contributing to reduced downtime and improved operational efficiency.
Technical Specifications
Parameter | Specification |
---|---|
Product Name | CC-TAIN11 |
Part Number | 51306515-175 |
Manufacturer | Honeywell |
Function | Analog Input Module (TAI – Transmitter Analog Input) |
Channels | 16 Analog Inputs |
Input Type | 4–20 mA, 1–5 V (software-configurable) |
Resolution | 16-bit ADC |
Input Accuracy | ±0.1% of span |
Power Supply | 24 VDC |
Operating Temperature | 0°C to 60°C (32°F to 140°F) |
Storage Temperature | -40°C to 85°C (-40°F to 185°F) |
Relative Humidity | 5% to 95% non-condensing |
Hot Swap Capability | Yes |
Isolation | Channel-to-channel and channel-to-system |
Diagnostics | Built-in self-diagnostics |
Compliance | CE, UL, CSA, FM |
Dimensions | 63.5 x 124.46 x 307.34 mm |
Weight | 0.5 kg |
Mounting | Chassis-based DIN Rail Mount |
Firmware Upgradable | Yes (via system software tools) |
Product Applications
The CC-TAIN11 is designed for a wide range of industrial automation and control applications where accurate and reliable analog input acquisition is critical. Key sectors and use cases include:
-
Oil & Gas: For pressure, temperature, and flow signal acquisition from field transmitters.
-
Petrochemical Plants: Real-time monitoring of batch processes and feedstock control.
-
Power Generation: Analog input monitoring from turbines, transformers, and load systems.
-
Water Treatment Facilities: pH, chlorine, and turbidity sensor integration.
-
Pharmaceutical Manufacturing: Input collection from cleanroom instrumentation and sterilization systems.
-
Food and Beverage: Process control of mixers, heaters, and filling systems.
-
Pulp & Paper: Monitoring consistency, flow, and chemical dosing in real time.
Product Advantages
-
High Precision Data Acquisition: Offers 16-bit resolution for accurate analog signal capture, ensuring process accuracy and reducing variability.
-
Integrated Diagnostics: Built-in diagnostics simplify maintenance and enhance system reliability through proactive fault detection.
-
Hot Swappable: Allows for module replacement without shutting down the system, minimizing process interruptions.
-
Compact Design: Small form factor enables easy installation in space-constrained environments.
-
Robust Isolation: Ensures protection from electrical noise and potential field faults, increasing operational lifespan.
-
Firmware Upgrade Capability: Extend functionality and security with seamless firmware updates.
-
Versatile Input Support: Supports both current and voltage analog signal types, enhancing field compatibility.
-
Certified for Global Use: Meets international compliance standards including CE, UL, and FM, ensuring global deployability.
10 Frequently Asked Questions (FAQs)
Q1: What is the primary function of the CC-TAIN11 module?
A1: The CC-TAIN11 functions as a 16-channel analog input module for interfacing with field transmitters that provide current or voltage signals.
Q2: Can the CC-TAIN11 module be used in hazardous environments?
A2: Yes, it complies with global certifications such as FM and CSA, making it suitable for deployment in classified or hazardous zones.
Q3: Is the module hot-swappable?
A3: Yes, the CC-TAIN11 supports hot-swapping for easy maintenance and zero system downtime.
Q4: What type of analog signals does the module accept?
A4: It accepts standard 4–20 mA and 1–5 VDC analog inputs.
Q5: Does it support redundancy?
A5: Yes, it can be configured within redundant I/O chassis to ensure high availability.
Q6: How is the module configured?
A6: Configuration is done through Honeywell’s system software, such as Experion PKS configuration tools.
Q7: Can I use this module with other Honeywell I/O modules?
A7: Yes, it is fully compatible with other modules in the same I/O chassis, allowing for mixed module configurations.
Q8: What is the maximum cable length from field devices to the module?
A8: Cable length depends on signal type, but for 4–20 mA inputs, up to 600 meters is generally acceptable using shielded twisted-pair cables.
Q9: What tools are required for firmware updates?
A9: Firmware updates can be performed using Honeywell’s control system engineering tools with USB or Ethernet connectivity.
Q10: How do I replace a faulty CC-TAIN11 module?
A10: Simply remove the module from the chassis using the release latch, insert the replacement, and reconfigure it using system tools—no power cycling required.
6 Related or Compatible Models
Model | Part Number | Function | Channels | Signal Type |
---|---|---|---|---|
CC-TAIX11 | 51305865-275 | Analog Input (Standard) | 16 | 4–20 mA |
CC-TAOY11 | 51305865-275 | Analog Output Module | 8 | 4–20 mA |
CC-TDIL01 | 51306860-175 | Digital Input Module | 32 | 24 VDC |
CC-TDOR01 | 51306861-175 | Digital Output Module | 32 | 24 VDC |
CC-PDIL01 | 51405040-175 | Pulse Input Module | 16 | Discrete Pulse |
CC-PDOB01 | 51405047-175 | Pulse Output Module | 16 | Pulse/Discrete |
6 Popular Honeywell Models
Model | Part Number | Function | Application | Channels |
---|---|---|---|---|
CC-PCF901 | 51405047-175 | Fieldbus Processor Module | I/O integration, system control | 1 |
CC-PAIH01 | 51405038-175 | HART Analog Input | Smart transmitters integration | 16 |
CC-PAOH01 | 51405039-175 | HART Analog Output | Actuator signal control | 8 |
CC-TCF901 | 51308363-175 | Control Firewall Module | Network segmentation | 1 |
CC-PDOB01 | 51405047-175 | Pulse Output Module | Pulse transmission | 16 |
CC-PDIL01 | 51405040-175 | Pulse Input Module | Counter/pulse signal acquisition | 16 |