Company Information | ||||||||
[email protected] | ||||||||
Mobile | +8613666084105 | |||||||
+8613666084105 | ||||||||
13666084105 | ||||||||
Add | Room 1004, No. 62 Xiangxiu Li, Siming District, Xiamen City, Fujian Province, China |
Product Introduction
The Honeywell FC-POB-0824 is a DCS System Spare Parts specifically designed for the Experion Process Knowledge System (PKS) Distributed Control System (DCS). As a part of the C300 controller family, this module plays a critical role in ensuring smooth, safe, and flexible control of process outputs across various industries, including oil & gas, power generation, petrochemical, water treatment, and manufacturing.
This output module facilitates the connection between the controller and field actuators, enabling operators to execute control strategies with precision. Designed for robust performance and ease of integration, it offers dependable operation in harsh industrial environments. As a spare part, the FC-POB-0824 ensures minimal downtime by providing fast replacement capability, ensuring that plant operations remain continuous and efficient.
Product Specifications
Parameter | Details |
---|---|
Model Number | FC-POB-0824 |
Product Type | DCS System Spare Parts |
System | Experion PKS (C300 Controller) |
Channels | 24 Digital Outputs |
Output Type | 24V DC Sourcing |
Isolation | Channel-to-Channel and Channel-to-Ground |
Operating Voltage | 20.4 to 28.8 VDC |
Load per Channel | Up to 0.5 A |
Maximum Module Load | 12 A total |
Diagnostics | Channel diagnostics with fault indication |
Operating Temperature | -40°C to +70°C |
Storage Temperature | -40°C to +85°C |
Relative Humidity | 5% to 95%, non-condensing |
Mounting | DIN Rail Mountable |
Communication Interface | FTE (Fault Tolerant Ethernet) |
Dimensions (W x H x D) | 104 x 130 x 60 mm |
Weight | 0.4 kg |
Compliance | CE, UL, CSA, RoHS |
Status Indicators | Per Channel LED Indicators |
Manufacturer | Honeywell International Inc. |
Applications
-
Oil & Gas Facilities: For controlling field actuators like solenoid valves and motor starters.
-
Power Plants: Used in turbine and boiler control systems for precise output signaling.
-
Chemical & Petrochemical Plants: Manages output devices in automated processing environments.
-
Water and Wastewater Treatment: Supports pump and valve actuation.
-
Pharmaceutical Manufacturing: Ensures accuracy in batch processing systems.
-
Industrial Automation: For use in any advanced industrial control system needing digital outputs.
Advantages
-
Reliable Performance: High-quality components and fault diagnostics ensure operational reliability.
-
Channel Isolation: Reduces the risk of cross-channel interference, enhancing system integrity.
-
Compact Design: Space-saving footprint for dense control cabinets.
-
Real-time Monitoring: Built-in LEDs and diagnostics for fast status evaluation.
-
Seamless Integration: Plug-and-play compatibility with Honeywell’s C300 controller platform.
-
Fast Replacement: Ideal as a spare part with minimal reconfiguration required.
-
Extended Environmental Tolerance: Operates in a wide temperature range, suitable for harsh sites.
-
Energy Efficient: Optimized load handling with minimal energy wastage.
-
Global Certification: Meets stringent international safety and compliance standards.
-
Long-Term Support: Backed by Honeywell’s global service and spare parts availability.
FAQ
-
How many field devices can the FC-POB-0824 module support simultaneously?
The FC-POB-0824 module supports up to 24 individual digital output channels, meaning you can connect and control up to 24 field actuators or devices at the same time, assuming load requirements are within specification. -
Is the module suitable for safety-critical applications in hazardous areas?
While the FC-POB-0824 offers high reliability and diagnostics, its use in safety-critical or SIL-rated systems depends on the system architecture and regulatory compliance. For SIL applications, confirm whether it’s deployed within a certified safety system. -
Can this output module be used in redundant configurations?
Yes, the FC-POB-0824 can be integrated into a redundant I/O system, especially when paired with Honeywell’s Fault Tolerant Ethernet (FTE) and redundant C300 controller setups, ensuring no single point of failure. -
Does the module require separate power wiring for each output channel?
No, the module is designed to source 24VDC output power, and channels share a common power bus. However, it is essential to respect the maximum total current rating to avoid overloads. -
What are the built-in diagnostic capabilities of this module?
The FC-POB-0824 offers per-channel diagnostics, including open circuit detection, short circuit protection, overcurrent indication, and onboard LEDs for channel-level fault visibility. -
How does the module behave during a system power-up or reboot?
At power-up, the module enters a safe output state until the controller sends valid output commands. This prevents unintentional energizing of field equipment during startup sequences. -
Is any software configuration required before using the module?
Yes, the module must be configured within Honeywell’s Control Builder or Experion engineering workstation, where each channel’s logic, behavior, and tag assignment are defined. -
What types of loads are supported—resistive, inductive, or both?
The module supports both resistive and inductive loads, but inductive loads such as solenoids or relays should have appropriate suppression (e.g., flyback diodes) to protect channel circuits. -
How should I handle grounding and shielding for noise immunity?
For industrial environments, proper shielding and grounding are essential. Connect shields to the cabinet ground at one end only, and follow Honeywell’s grounding guidelines to avoid ground loops and signal noise. -
What maintenance steps are recommended to ensure long-term reliability?
Perform regular visual inspections for LED status, verify terminal tightness, check for signs of overheating, and periodically run diagnostic checks through the DCS interface to detect abnormal output behavior or channel degradation.
Recommended Related Models (Same Series or Functionality)
Model Number | Description | Channels | Type |
---|---|---|---|
FC-PIB-0811 | Digital Input Module, 24VDC | 24 | Digital Input |
FC-AO-0410 | Analog Output Module | 4 | Analog Output |
FC-AI-1100 | Analog Input Module | 8 | Analog Input |
FC-TSGASH-0001 | Termination Assembly for FC-POB modules | N/A | Terminal Strip |
FC-PDB-0824 | Power Distribution Board | 24 | Power Output |
FC-IOC-0001 | Input/Output Controller for C300 | N/A | Controller Interface |
Popular Honeywell Models (High Demand Across Industries)
Model Number | Description | Application Area |
---|---|---|
CC-PCF901 | Control Firewall Module | Cybersecurity in DCS |
MC-PAIH03 | Analog Input Module (8-ch) | Field Analog Signal Input |
TC-PPD011 | Power Supply Module | System Power Supply |
51309218-175 | Serial Interface Module | Legacy Communication |
51405040-175 | Cable Interface Module | Remote I/O Communication |
MC-TDIY22 | Digital Input Module | General Process Automation |