Company Information | ||||||||
[email protected] | ||||||||
Mobile | +8613666033393 | |||||||
+8613666033393 | ||||||||
13666033393 | ||||||||
Add | Room 1004, No. 62 Xiangxiu Li, Siming District, Xiamen City, Fujian Province, China |
Product Introduction
The Honeywell FC-SAL-1620M Safety Management System Module is a critical component of Honeywell’s Safety Manager platform, a SIL 3 TÜV-certified safety system that supports both safety and pr
ocess control functions in demanding industrial environments. As part of the Fail-Safe Controller (FSC) architecture, the FC-SAL-1620M is specifically designed to ensure the integrity, reliability, and availability of safety-critical functions across various industrial sectors, including oil and gas, petrochemical, power generation, and pharmaceuticals.
This module provides high-integrity I/O interfacing, acting as a safety input/output module that can be configured and diagnosed through Honeywell’s Safety Builder or Experion PKS engineering tools. It is engineered to support applications that require stringent functional safety, real-time diagnostics, redundancy, and continuous operation under harsh environmental conditions.
Product Specifications
Parameter | Specification |
---|---|
Model Number | FC-SAL-1620M |
System Compatibility | Safety Manager, Experion PKS, FSC System |
Functionality | Safety Analog Input/Output Module (configurable) |
Channels | 16 Channels, configurable for analog input or output |
Signal Type | 4–20 mA current loop, HART capable (optional) |
Resolution | 16-bit conversion |
Input Accuracy | ±0.1% of span |
Output Accuracy | ±0.1% of span |
Diagnostics | Channel-level diagnostics, loop monitoring, power loss detection |
Redundancy Support | Yes – module level and power input redundancy |
Hot Swap Support | Yes – with no process interruption |
Communication Protocol | Proprietary SafeNet / FTE (via Safety Manager backplane) |
Configuration Tools | Safety Builder, Safety Designer, Experion Control Builder |
Status Indicators | Per-channel and module health LEDs |
Power Supply Voltage | Supplied via I/O chassis backplane |
Operating Temperature | -20°C to +60°C |
Storage Temperature | -40°C to +85°C |
Humidity | 5% to 95% RH, non-condensing |
Shock and Vibration Resistance | Compliant with IEC 60068-2-6 and 2-27 |
Certifications | TÜV (SIL3), CE, ATEX, GOST, IECEx, CSA |
Mounting Type | DIN rail or rack mount (in standard Safety Manager chassis) |
Dimensions (H × W × D) | 130 × 50 × 120 mm |
Weight | 0.3 kg |
Product Applications
The FC-SAL-1620M is deployed in applications where functional safety and continuous availability are essential. The module plays a central role in ensuring safe process shutdown, interlocks, and emergency controls.
-
Emergency Shutdown Systems (ESD): Used in upstream and downstream oil & gas plants to ensure safe plant isolation during critical events.
-
Burner Management Systems (BMS): Provides real-time safety monitoring and control of combustion systems in power plants and refineries.
-
Fire & Gas Detection: Integrates with detectors and gas analyzers to trigger safe responses during fire or hazardous gas leaks.
-
Boiler Safety Systems: Ensures fail-safe operation and shutdown of high-pressure boilers in process industries.
-
Overpressure Protection Systems: Works alongside pressure transmitters to initiate relief or depressurization procedures.
-
HIPPS (High Integrity Pressure Protection Systems): Ensures compliance with safety integrity requirements for pipeline protection.
Product Advantages
-
SIL 3 Certified: Complies with IEC 61508 standards, offering maximum safety assurance for high-risk industries.
-
Dual Redundancy Capabilities: Supports redundant power, module, and I/O configurations for uninterrupted operation.
-
Hot Swappable Design: Enables safe module replacement without process downtime.
-
Advanced Diagnostics: Real-time fault detection at the channel and module level enhances preventive maintenance.
-
Modular Scalability: Easily integrates into existing Safety Manager architectures for flexible expansion.
-
Universal Channel Configuration: Reduces inventory and engineering time by supporting multiple I/O signal types.
-
Secure Integration with Experion PKS: Ensures full compatibility with Honeywell’s flagship control platforms.
-
Built-in Loop Monitoring: Offers continuous feedback on loop integrity to prevent hidden faults.
FAQ
-
Can each channel of the FC-SAL-1620M be configured as input or output?
Yes, each of the 16 channels is software configurable for either analog input or output function. -
Does the module support HART communication?
HART support is optional and requires proper configuration via Safety Builder. -
Is the FC-SAL-1620M module hot-swappable?
Yes, it supports hot-swapping within a redundant configuration to avoid downtime. -
Can the module be used in a SIL 3 loop?
Absolutely, the FC-SAL-1620M is TÜV certified for use in SIL 3 safety instrumented functions. -
What happens if one channel fails?
The module performs continuous diagnostics and will flag the exact faulty channel, enabling selective deactivation without affecting others. -
Is redundancy supported at the module level?
Yes, redundancy is supported for both the module and power input, depending on the system configuration. -
What is the input signal resolution?
The module offers a 16-bit resolution for accurate analog signal conversion. -
Can this module be integrated with standard PLCs?
Direct integration is designed for Honeywell Safety Manager, though third-party interfacing is possible via protocol converters. -
What engineering tools are used for configuration?
Configuration is performed through Safety Builder or integrated with Experion’s Control Builder tools. -
How does the module handle field power loss?
It has built-in loop supervision and diagnostics to detect and report power loss on individual channels.
Related Models (Same Series or Functional Category)
Model | Description |
---|---|
FC-SDI-1624 | 16-point Digital Input Safety Module |
FC-SDO-0824 | 8-point Digital Output Safety Module |
FC-AIO-1620 | Universal Analog I/O Module for Safety Manager |
FC-PDB-1×24 | Power Distribution Board for Safety I/O Modules |
FC-PSU-UNIV | Universal Redundant Power Supply Module |
FC-QPP-0001 | Quad Processor Platform Controller Module |
Popular Honeywell Models (Same Brand)
Model | Function |
---|---|
C300 Controller | Advanced process controller for Experion PKS |
HC900 Controller | Modular hybrid controller for safety and process applications |
FIM4 | Field Interface Module for integration of remote I/O |
RM7800 Series | Flame safeguard and burner control systems |
FSC Processor | High-integrity programmable safety logic processor |
UCN Bridge | Communication bridge for legacy system migration to Experion |