Product Introduction
The Honeywell TK-CRR014 Redundant Net Panel Interface Module is a critical hardware component designed to support redundancy and reliable communication within Honeywell’s control and automation platforms. It acts as a high-performance interface for redundant network panels, ensuring seamless data transfer and communication reliability in distributed control system (DCS) environments such as Experion PKS and TPS/TDC3000.
The module is engineered for mission-critical industrial applications where network reliability and fault tolerance are essential. By enabling redundant connections between network nodes, the TK-CRR014 minimizes downtime, eliminates single points of failure, and supports robust communication pathways in plant operations. With diagnostic capabilities, high compatibility, and a design optimized for industrial resilience, it ensures continuous and secure operation of process control systems.
Product Specifications
Parameter | Specification |
---|---|
Model | Honeywell TK-CRR014 |
Function | Redundant Net Panel Interface Module |
System Compatibility | Honeywell Experion PKS, TPS, TDC3000 |
Communication Protocol | High-speed redundant communication bus |
Input Voltage | 24 V DC |
Power Consumption | ≤ 20 W |
Redundancy Features | Supports dual redundant paths, automatic switchover |
Status Indicators | LED diagnostics for link, fault, and redundancy |
Operating Temperature | 0 to 55 °C |
Storage Temperature | -20 to 70 °C |
Humidity | 10–90% RH, non-condensing |
Cooling Method | Natural convection |
Mounting Type | Rack-mounted |
Dimensions (W x H x D) | 250 x 135 x 210 mm |
Weight | 0.5 kg |
Product Applications
The TK-CRR014 is widely used in process industries where redundant networking and high communication reliability are required:
-
Oil & Gas – Ensures fault-tolerant networking for refining, drilling, and pipeline control systems.
-
Power Generation – Provides redundant communication between controllers and operator stations in thermal, hydro, and nuclear plants.
-
Petrochemical & Chemical Plants – Enhances reliability of distributed control networks in high-risk processing environments.
-
Pharmaceutical Manufacturing – Supports validated communication systems for batch and continuous processes.
-
Water & Wastewater Treatment – Maintains uninterrupted monitoring and control across distributed facilities.
-
Pulp & Paper – Enables stable and redundant communications across multiple process areas.
Product Advantages
-
High Reliability – Provides secure redundant communication channels that automatically switch during failures.
-
Seamless Integration – Fully compatible with Honeywell DCS platforms, including Experion PKS and legacy TDC3000.
-
Fault Tolerance – Eliminates single points of failure in industrial communication networks.
-
Advanced Diagnostics – Built-in LED indicators for real-time status and troubleshooting.
-
Scalable Design – Can be deployed in both small-scale and large-scale distributed control networks.
-
Industrial Durability – Designed to operate in demanding environments with temperature stability and EMC compliance.
FAQ
-
What type of redundancy does the TK-CRR014 support?
It provides dual redundant communication paths with automatic failover. -
How does the module indicate communication faults?
LED indicators display fault, active link, and redundancy status. -
Is the module hot-swappable in a live system?
Yes, when installed in supported Honeywell racks, it can be hot-swapped. -
Can the TK-CRR014 operate in mixed legacy and modern networks?
Yes, it supports both TDC3000 and Experion PKS environments. -
What happens during a network path failure?
The module automatically switches to the redundant path without interrupting data communication. -
Does the module provide built-in diagnostics?
Yes, it has self-checking functions and LED-based diagnostic reporting. -
How does the TK-CRR014 ensure data integrity in redundancy?
It continuously synchronizes both paths to prevent data loss or duplication. -
Can multiple TK-CRR014 modules be used in a single system?
Yes, multiple modules can be deployed to extend redundant communication across networks. -
Does it require external cooling for continuous operation?
No, it relies on natural convection cooling and does not require additional fans. -
What protocols are supported for redundancy communication?
It supports Honeywell’s proprietary high-speed redundant bus protocols optimized for DCS reliability.
Recommended Related Models (Same Series / Similar)
Model | Description |
---|---|
TK-CRR012 | Network interface module for redundant communication |
TK-CRR013 | Enhanced redundant control network interface |
TK-CRR015 | Advanced redundant net panel interface with extended diagnostics |
TK-SMPC01 51309516-175 | Power adaptor module for Honeywell DCS |
TK-PSM02 51309276-175 | Redundant power supply module |
TK-CRR016 | High-capacity redundant communication module |
Popular Honeywell Models (Same Brand)
Model | Description |
---|---|
CC-PDIL01 | Digital input module for Experion PKS |
CC-PAIH01 | High-performance analog input module |
CC-PDOB01 | Digital output module with isolation |
CC-TDIL01 | Redundant digital input interface |
CC-TAOH01 | Analog output module for process automation |
CC-PAOH01 | Output module with integrated power conditioning |