Product Introduction
The Schneider 140ACI04000C is a high-performance analog input module engineered for use with Modicon Quantum automation systems. It provides reliable analog signal acquisition, translating process signals from field instruments into accurate digital values that can be processed by the PLC. Featuring 8 input channels and compatibility with a wide range of voltage and current signals, the module is ideal for complex industrial automation tasks.
Built with Schneider’s renowned engineering quality, the 140ACI04000C is suitable for harsh industrial environments, providing high levels of immunity against electrical noise, vibrations, and temperature variations. It supports both single-ended and differential input wiring, enhancing its versatility in real-world applications.
Product Specifications
| Parameter | Details |
|---|---|
| Model Number | 140ACI04000C |
| Manufacturer | Schneider Electric |
| Product Type | Analog Input Module |
| Number of Channels | 8 Channels |
| Input Type | Voltage and Current (±10 V, 0-20 mA) |
| Resolution | 15 Bits |
| Conversion Type | Sigma-Delta |
| Update Time | < 1 ms per channel |
| Input Impedance | > 10 MΩ for voltage, 250 Ω for current |
| Input Range | ±10 V, 0-20 mA, 4-20 mA |
| Isolation | 2500 Vrms channel-to-bus |
| Accuracy | ±0.1% Full Scale at 25°C |
| Calibration | Factory-calibrated |
| Power Consumption | 2.5 W (typical) |
| Mounting Type | Rack-mounted (Quantum I/O base) |
| Operating Temperature | 0 to 60°C (32 to 140°F) |
| Storage Temperature | -40 to 85°C (-40 to 185°F) |
| Humidity | 5% to 95% RH non-condensing |
| Dimensions (H x W x D) | 103.9 × 40.3 × 250 mm |
| Weight | 0.3 kg |
| Certifications | CE, UL, CSA, ATEX, FM |
Applications
The 140ACI04000C is designed for a wide range of industrial applications that require precision analog signal acquisition. Typical use cases include:
-
Process Control Systems: Ideal for capturing analog signals from pressure, temperature, level, and flow transmitters.
-
Manufacturing Automation: Used in monitoring and control of automated production lines.
-
Water and Wastewater Treatment: Enables real-time monitoring of water quality parameters.
-
Power and Energy Management: Suitable for analog sensor integration in substations or energy plants.
-
Oil & Gas: Interfaces with critical field instruments in hazardous environments.
-
Pharmaceuticals and Food Processing: Ensures accurate process control to meet strict quality standards.
Product Advantages
-
High Precision: 15-bit resolution provides excellent signal fidelity and accuracy.
-
Wide Input Compatibility: Supports both current and voltage inputs, ensuring flexible field integration.
-
Strong Electrical Isolation: Protects the PLC system and enhances safety in high-noise environments.
-
Fast Response Time: Ideal for applications requiring real-time data acquisition.
-
Robust Design: Built to perform reliably in harsh industrial settings.
-
Ease of Integration: Compatible with Schneider Quantum racks and tools, minimizing engineering effort.
-
Long Lifecycle Support: Backed by Schneider Electric’s global support and extended product lifecycle.
Frequently Asked Questions (FAQ)
-
What types of signals can the 140ACI04000C module read?
It can read both voltage (±10 V) and current (0-20 mA, 4-20 mA) analog signals. -
How many channels does this module support?
The module supports 8 independent analog input channels. -
Is the module isolated?
Yes, each channel is optically isolated from the backplane and other channels, providing 2500 Vrms isolation. -
What is the typical accuracy of the module?
The typical accuracy is ±0.1% of full scale at 25°C. -
What is the resolution of the analog-to-digital converter?
It uses a 15-bit resolution ADC. -
Can this module be used in hazardous environments?
Yes, it meets certifications such as ATEX and FM, suitable for hazardous locations. -
Does it support HART communication?
No, the 140ACI04000C does not support HART protocol. -
Is calibration required?
The module comes factory-calibrated and does not require field calibration under normal conditions. -
What software is used to configure the module?
Schneider Unity Pro or EcoStruxure Control Expert can be used for configuration. -
Can it be used with other brands of PLCs?
It is specifically designed for Schneider Modicon Quantum systems, and not recommended for third-party PLCs.
Related Models from the Same Series
| Model | Description | Input Type | Channels | Resolution |
|---|---|---|---|---|
| 140ACI03000 | Analog Input Module | Current | 8 | 12-bit |
| 140ACI05100 | Analog Input Module | Voltage | 16 | 12-bit |
| 140ACI02000 | Analog Input Module | Voltage | 8 | 12-bit |
| 140ACI05000 | Analog Input Module | Voltage | 16 | 12-bit |
| 140ACI04000C | Analog Input Module (Current & Voltage) | Current/Voltage | 8 | 15-bit |
| 140ACI06000 | High-Speed Analog Input Module | Voltage | 8 | 16-bit |
Popular Schneider Models
| Model | Description | Type | Application |
|---|---|---|---|
| 140CPU65160S | Quantum PLC Processor | CPU Module | High-performance PLC |
| BMXAMO0410 | Analog Output Module | Analog Output | Mid-range PLC systems |
| TM221CE16T | Modicon M221 Logic Controller | Compact PLC | Machine control |
| ATV930U75N4 | Altivar Process Drive | Variable Speed Drive | Motor control |
| BMEP583020 | Modicon M580 CPU | Ethernet PAC | Process automation |
| TSXPSY2600 | Power Supply Module | Power Supply | For TSX Premium PLC |
Excellent PLC