Product Overview
The Schneider Electric STBXBE1300 is a Backplane Expansion (BOS) Internal Bus Module specifically designed for the Advantys STB distributed I/O system. This module serves as a bridge between two power distribution segments on the same STB island, enabling seamless data exchange across segmented I/O modules while keeping power domains isolated. It is an essential component for modular I/O configurations that require expanded connectivity and electrical separation.
The STBXBE1300 enhances the flexibility and reliability of STB I/O architectures by supporting high-speed communication between segments without compromising signal integrity or control precision.
Key Features
-
Internal BOS (Backplane Output Segment) bus extension module
-
Bridges communication between I/O segments on an STB island
-
Supports electrical isolation between power segments
-
Ensures consistent I/O bus continuity across segmented zones
-
DIN rail-mountable design for simple integration
-
Operates passively without additional power supply
-
Compact format with hot-swap capability
-
Designed for industrial automation environments
-
Works in tandem with STBPDT modules and terminal bases
-
Complies with CE, UL, CSA, and RoHS standards
Technical Specifications
| Parameter | Specification |
|---|---|
| Model Number | STBXBE1300 |
| Function | Internal bus expansion module (BOS bridge) |
| System Compatibility | Advantys STB distributed I/O system |
| Power Supply | Not required (passive module) |
| Mounting Type | DIN rail (35 mm symmetrical) |
| Backplane Support | Bridges I/O modules across segmented islands |
| Status Indicators | None |
| Hot-Swappable | Yes |
| Operating Temperature | 0°C to +55°C |
| Storage Temperature | -40°C to +85°C |
| Relative Humidity | 5% to 95% (non-condensing) |
| Dimensions | Package size: 25 x 80 x 130mm |
| Weight | Package size 0.125kg |
| Certifications | CE, UL, CSA, RoHS |
Industry Applications
-
Material Handling Systems: For modular conveyor and sorting equipment
-
Packaging Machines: Enables power segment separation across zones
-
Process Automation: Ensures safe segmentation in chemical and water treatment systems
-
Pharmaceutical Equipment: Supports isolated control of critical and non-critical zones
-
Food and Beverage: Reliable segment linking across multiple processing stations
-
Building Automation: I/O expansion in HVAC and lighting control systems
Product Advantages
-
Flexible System Expansion: Bridges STB power segments without compromising control bus communication
-
Segmented Power Architecture: Supports logic and I/O electrical isolation on the same island
-
Simple Installation: Slim DIN rail form factor installs like other STB modules
-
No Extra Power Required: Passive design simplifies power planning
-
Hot-Swappable: Replaceable during live operation with minimal system disruption
-
Reliable Performance: Maintains signal integrity across long I/O islands
-
Plug-and-Play: Auto-detection by the Advantys STB system
-
Space-Saving Design: Only 12 mm wide for compact panel layouts
-
Industrial-Grade Durability: Withstands vibration and temperature changes
-
Global Compliance: Certified for use in international markets
Frequently Asked Questions (FAQ)
-
Q: What is the function of the STBXBE1300 module?
A: It bridges the backplane communication bus across segmented power sections of the same STB I/O island. -
Q: Does it provide power to the I/O modules?
A: No, it only transmits data; power must be provided by a power distribution module like STBPDT3100. -
Q: Can it be hot-swapped?
A: Yes, it supports hot swapping without interrupting island operations. -
Q: Is this a powered module?
A: No, it is a passive module and does not require an external power supply. -
Q: What happens if I don’t use this module between power segments?
A: Communication between segments will not occur, and the system will treat them as isolated. -
Q: Can I use more than one STBXBE1300 in the same island?
A: Yes, multiple BOS expansion modules can be used to interconnect multiple segments. -
Q: Does it support diagnostics or status LEDs?
A: No, it has no status indicators as it operates passively. -
Q: Is it necessary in every STB installation?
A: Only when segmenting power and needing to maintain bus continuity between those segments. -
Q: What is the typical width of the module?
A: It is 12 mm wide, similar to standard STB modules. -
Q: Does it work with all STB base modules?
A: Yes, it is designed to work with all standard STB base and terminal modules.
Related Modules
| Model Number | Description |
|---|---|
| STBPDT3100 | Standard power distribution module for STB islands |
| STBPDT3105 | Advanced segmented power distribution module |
| STBNIP2212 | Ethernet/IP network interface module for STB |
| STBXTS1100 | Terminal base for STB modules |
| STBACO1220 | 12-channel analog output module |
| STBDAI8230 | 8-channel analog input module |
Popular Schneider Electric Modular I/O Components
| Model Number | Description |
|---|---|
| BMXCPS3020 | 24V DC power supply for Modicon M340 |
| BMXP342020 | Modicon M340 CPU with USB and Ethernet |
| TM221CE24T | Modicon M221 PLC with Ethernet |
| TM3DI8 | 8-channel digital input expansion module (TM3) |
| TM5SAK3HT | Terminal block for TM5 distributed I/O system |
| BMECRA31210 | M580 rack backplane extension module |
Excellent PLC