Product Overview
The Schneider Electric TCSEGDB23F24FA is a high-performance Ethernet to Profibus-DP proxy module, designed to integrate Profibus-DP slave devices into Modicon M580 and M340 Ethernet architectures. By bridging the gap between legacy fieldbus systems and modern Ethernet networks, this module offers seamless communication, allowing plants to retain existing devices while benefiting from advanced Ethernet diagnostics, configuration tools, and network transparency.
It is part of the Modicon Communication Modules lineup and plays a critical role in modernizing automation systems without needing to overhaul field equipment.
Key Features
-
Converts Ethernet/IP to Profibus-DP
-
Supports Modicon M580 and M340 controllers
-
Compatible with Unity Pro and EcoStruxure Control Expert
-
Enables integration of existing Profibus-DP slaves
-
Diagnostic LED indicators for quick troubleshooting
-
DIN rail mountable, compact industrial design
-
Redundant Ethernet and Profibus support
-
Built-in Web server for remote configuration and monitoring
Technical Specifications
| Item | Specification |
|---|---|
| Model Number | TCSEGDB23F24FA |
| Product Type | Ethernet to Profibus-DP Proxy Module |
| Ethernet Ports | 2 x RJ45 (10/100 Mbps, Ethernet/IP) |
| Profibus Interface | 1 x DB9 Female (DP Slave support) |
| Supported Protocols | Ethernet/IP, Modbus TCP, Profibus-DP |
| Configuration Software | Unity Pro / EcoStruxure Control Expert |
| Max Number of Devices | Up to 125 Profibus-DP slaves |
| Supply Voltage | 24 V DC |
| Power Consumption | ≤ 5 W |
| Diagnostic LEDs | Yes (Status, Ethernet, Profibus) |
| Mounting | DIN rail |
| Operating Temperature | 0°C to +60°C |
| Storage Temperature | -40°C to +85°C |
| Relative Humidity | 5% to 95% non-condensing |
| Dimensions | Package size 60 x 180 x 260mm |
| Weight | Package weight 0.69kg |
| Certifications | CE, UL, CSA, RoHS, ATEX Zone 2 (optional) |
Industry Applications
-
Industrial automation systems with legacy Profibus-DP devices
-
Process control in oil & gas, chemicals, and power generation
-
Factory modernization where Ethernet upgrades are underway
-
Water treatment plants with distributed Profibus instrumentation
-
Machine automation retaining Profibus-DP field equipment
-
SCADA systems requiring backward compatibility with fieldbus
Advantages
-
Cost-Efficient Modernization: Integrates Profibus-DP without replacing devices
-
Seamless Communication: Transparent proxy between Ethernet and Profibus
-
Advanced Diagnostics: Built-in LEDs and web server simplify troubleshooting
-
Scalable: Supports large Profibus networks up to 125 slaves
-
Flexible Architecture: Works with M340, M580, and other Ethernet-based PLCs
-
Rugged Design: Built to withstand industrial environments
-
Remote Access: Embedded web server allows remote monitoring
-
Interoperability: Facilitates multi-vendor device integration
-
Minimal Downtime: Hot swappable and easily replaceable
-
Simplified Configuration: Intuitive setup using EcoStruxure tools
Frequently Asked Questions (FAQ)
-
What does the TCSEGDB23F24FA module do?
It acts as a proxy to connect Profibus-DP slave devices to Ethernet-based PLCs like M580 and M340. -
Which controllers is it compatible with?
It supports Modicon M580 and M340 series. -
Can I use this module to upgrade legacy Profibus systems?
Yes, it allows existing Profibus-DP field devices to be retained while modernizing the control system. -
How many Profibus-DP devices can it support?
It can support up to 125 slave devices. -
What software is used to configure the module?
Unity Pro or EcoStruxure Control Expert software is used. -
Does it support remote monitoring?
Yes, it includes a built-in web server for remote diagnostics. -
Is it hot-swappable?
While designed for fast replacement, confirm your system allows hot swapping before attempting it. -
What are the available communication ports?
It has 2 Ethernet RJ45 ports and 1 Profibus DB9 port. -
What is the power requirement for this module?
It requires a 24 V DC power supply with max 5 W consumption. -
Is it suitable for harsh industrial environments?
Yes, it is rated for industrial temperature and humidity ranges and is DIN rail mountable.
Related Schneider Models
| Model Number | Description |
|---|---|
| TCSEGDB23F24FA | Ethernet to Profibus-DP Proxy Module |
| BMXNOE0100 | Ethernet communication module for M340 |
| BMXNOM0200 | Modbus communication module |
| TSXETY4103 | Ethernet TCP/IP module for Quantum PLCs |
| BMENOC0301 | M580 communication module with dual ports |
| TCSESM043F2CU0 | Managed Ethernet Switch for industrial networks |
Popular Schneider Electric Modules
| Model Number | Description |
|---|---|
| BMXDDI3202K | 32-channel discrete input module |
| BMXAMI0410 | 4-channel analog input module |
| BMXAMO0410 | 4-channel analog output module |
| BMXP342020 | Modicon M340 CPU module |
| BMXERT1604 | Remote I/O module for distributed architecture |
| BMXCPS2010 | Power supply module for M340 PLC |
Excellent PLC