<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>1606-XLS480F-3 - Excellent PLC</title>
	<atom:link href="https://www.excellentplc.com/tag/1606-xls480f-3/feed/" rel="self" type="application/rss+xml" />
	<link>https://www.excellentplc.com/tag/1606-xls480f-3/</link>
	<description></description>
	<lastBuildDate>Wed, 15 Apr 2026 02:26:09 +0000</lastBuildDate>
	<language>zh-Hans</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.9.4</generator>

<image>
	<url>https://www.excellentplc.com/wp-content/uploads/2025/08/cropped-cropped-logo-192x192-1-32x32.jpg</url>
	<title>1606-XLS480F-3 - Excellent PLC</title>
	<link>https://www.excellentplc.com/tag/1606-xls480f-3/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Allen Bradley 1606-XLS480F-3 Power Supply</title>
		<link>https://www.excellentplc.com/allen-bradley-1606-xls480f-3-power-supply/</link>
					<comments>https://www.excellentplc.com/allen-bradley-1606-xls480f-3-power-supply/#respond</comments>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Wed, 15 Apr 2026 02:26:09 +0000</pubDate>
				<category><![CDATA[Allen Bradley]]></category>
		<category><![CDATA[1606-XLS480F-3]]></category>
		<category><![CDATA[Allen Bradley 1606-XLS480F-3]]></category>
		<category><![CDATA[Power Supply]]></category>
		<guid isPermaLink="false">https://www.excellentplc.com/?p=127126</guid>

					<description><![CDATA[<p>Product Introduction The Allen Bradley 1606-XLS480F-3 P [&#8230;]</p>
<p><a href="https://www.excellentplc.com/allen-bradley-1606-xls480f-3-power-supply/">Allen Bradley 1606-XLS480F-3 Power Supply</a>最先出现在<a href="https://www.excellentplc.com">Excellent PLC</a>。</p>
]]></description>
										<content:encoded><![CDATA[<!DOCTYPE html PUBLIC "-//W3C//DTD HTML 4.0 Transitional//EN" "http://www.w3.org/TR/REC-html40/loose.dtd">
<html><body><h3 data-section-id="kz71jh" data-start="6" data-end="32"><img fetchpriority="high" decoding="async" class="alignnone size-full wp-image-127127" src="https://www.excellentplc.com/wp-content/uploads/2026/04/1606-XLS480F-3-2.jpg" alt="Allen Bradley 1606-XLS480F-3 Power Supply" width="800" height="800"></h3>
<h3 data-section-id="kz71jh" data-start="6" data-end="32">Product Introduction</h3>
<p data-start="33" data-end="407">The Allen Bradley 1606-XLS480F-3 Power Supply is a high-efficiency three-phase AC/DC power supply designed for industrial systems that require reliable and stable 48V DC power. As part of the <strong data-start="225" data-end="262">1606-XLS Series Performance Power</strong> portfolio from <span class="hover:entity-accent entity-underline inline cursor-pointer align-baseline"><span class="whitespace-normal">Allen-Bradley</span></span>, this model is engineered to support demanding automation and process control environments.</p>
<p data-start="409" data-end="716">With a wide three-phase AC input range of 380&ndash;480V AC, the unit converts incoming power into a regulated 48&ndash;56V DC output. Delivering up to 480W and 10A output current, it is particularly suited for applications requiring higher DC voltage levels, such as industrial networking, drives, and control systems.</p>
<p data-start="718" data-end="989">The compact housing combined with DIN rail mounting and spring-clamp terminals ensures quick installation and secure wiring. Its robust internal design, high efficiency, and fanless cooling concept make it suitable for continuous operation in harsh industrial conditions.</p>
<hr data-start="991" data-end="996">
<h3 data-section-id="vum7lv" data-start="997" data-end="1025">Product Specifications</h3>
<div class="TyagGW_tableContainer">
<div class="group TyagGW_tableWrapper flex flex-col-reverse w-fit" tabindex="-1">
<table class="w-fit min-w-(--thread-content-width)" data-start="1027" data-end="1780">
<thead data-start="1027" data-end="1058">
<tr data-start="1027" data-end="1058">
<th class="" data-start="1027" data-end="1043" data-col-size="sm"><strong data-start="1029" data-end="1042">Parameter</strong></th>
<th class="" data-start="1043" data-end="1058" data-col-size="sm">Description</th>
</tr>
</thead>
<tbody data-start="1089" data-end="1780">
<tr data-start="1089" data-end="1119">
<td data-start="1089" data-end="1101" data-col-size="sm"><strong data-start="1091" data-end="1100">Model</strong></td>
<td data-start="1101" data-end="1119" data-col-size="sm">1606-XLS480F-3</td>
</tr>
<tr data-start="1120" data-end="1163">
<td data-start="1120" data-end="1133" data-col-size="sm"><strong data-start="1122" data-end="1132">Series</strong></td>
<td data-start="1133" data-end="1163" data-col-size="sm">1606-XLS Performance Power</td>
</tr>
<tr data-start="1164" data-end="1198">
<td data-start="1164" data-end="1189" data-col-size="sm"><strong data-start="1166" data-end="1188">Rated Output Power</strong></td>
<td data-start="1189" data-end="1198" data-col-size="sm">480 W</td>
</tr>
<tr data-start="1199" data-end="1234">
<td data-start="1199" data-end="1220" data-col-size="sm"><strong data-start="1201" data-end="1219">Output Voltage</strong></td>
<td data-start="1220" data-end="1234" data-col-size="sm">48&ndash;56 V DC</td>
</tr>
<tr data-start="1235" data-end="1264">
<td data-start="1235" data-end="1256" data-col-size="sm"><strong data-start="1237" data-end="1255">Output Current</strong></td>
<td data-start="1256" data-end="1264" data-col-size="sm">10 A</td>
</tr>
<tr data-start="1265" data-end="1321">
<td data-start="1265" data-end="1291" data-col-size="sm"><strong data-start="1267" data-end="1290">Input Voltage Range</strong></td>
<td data-start="1291" data-end="1321" data-col-size="sm">380&ndash;480 V AC (Three Phase)</td>
</tr>
<tr data-start="1322" data-end="1359">
<td data-start="1322" data-end="1339" data-col-size="sm"><strong data-start="1324" data-end="1338">Input Type</strong></td>
<td data-start="1339" data-end="1359" data-col-size="sm">AC (Three Phase)</td>
</tr>
<tr data-start="1360" data-end="1407">
<td data-start="1360" data-end="1384" data-col-size="sm"><strong data-start="1362" data-end="1383">Power Supply Type</strong></td>
<td data-start="1384" data-end="1407" data-col-size="sm">AC/DC Switched Mode</td>
</tr>
<tr data-start="1408" data-end="1446">
<td data-start="1408" data-end="1428" data-col-size="sm"><strong data-start="1410" data-end="1427">Mounting Type</strong></td>
<td data-start="1428" data-end="1446" data-col-size="sm">DIN Rail Mount</td>
</tr>
<tr data-start="1447" data-end="1493">
<td data-start="1447" data-end="1467" data-col-size="sm"><strong data-start="1449" data-end="1466">Terminal Type</strong></td>
<td data-start="1467" data-end="1493" data-col-size="sm">Spring-Clamp Terminals</td>
</tr>
<tr data-start="1494" data-end="1552">
<td data-start="1494" data-end="1511" data-col-size="sm"><strong data-start="1496" data-end="1510">Efficiency</strong></td>
<td data-start="1511" data-end="1552" data-col-size="sm">High efficiency (typically above 94%)</td>
</tr>
<tr data-start="1553" data-end="1622">
<td data-start="1553" data-end="1579" data-col-size="sm"><strong data-start="1555" data-end="1578">Protection Features</strong></td>
<td data-start="1579" data-end="1622" data-col-size="sm">Overload, overvoltage, thermal shutdown</td>
</tr>
<tr data-start="1623" data-end="1666">
<td data-start="1623" data-end="1644" data-col-size="sm"><strong data-start="1625" data-end="1643">Cooling Method</strong></td>
<td data-start="1644" data-end="1666" data-col-size="sm">Convection cooling</td>
</tr>
<tr data-start="1667" data-end="1716">
<td data-start="1667" data-end="1690" data-col-size="sm"><strong data-start="1669" data-end="1689">Housing Material</strong></td>
<td data-start="1690" data-end="1716" data-col-size="sm">Industrial-grade metal</td>
</tr>
<tr data-start="1717" data-end="1755">
<td data-start="1717" data-end="1734" data-col-size="sm"><strong data-start="1719" data-end="1733">Dimensions</strong></td>
<td data-start="1734" data-end="1755" data-col-size="sm">127 x 65 x 124 mm</td>
</tr>
<tr data-start="1756" data-end="1780">
<td data-start="1756" data-end="1769" data-col-size="sm"><strong data-start="1758" data-end="1768">Weight</strong></td>
<td data-start="1769" data-end="1780" data-col-size="sm">0.87 kg</td>
</tr>
</tbody>
</table>
</div>
</div>
<hr data-start="1782" data-end="1787">
<h3 data-section-id="17tovxr" data-start="1788" data-end="1806">Applications</h3>
<p data-start="1808" data-end="1935">&bull; <strong data-start="1810" data-end="1843">Industrial automation systems</strong> requiring stable <strong data-start="1861" data-end="1877">48V DC power</strong> for controllers, I/O systems, and communication modules</p>
<p data-start="1940" data-end="2047">&bull; <strong data-start="1942" data-end="1976">Three-phase power environments</strong> such as manufacturing plants where <strong data-start="2012" data-end="2033">380&ndash;480V AC input</strong> is standard</p>
<p data-start="2052" data-end="2181">&bull; <strong data-start="2054" data-end="2089">Industrial networking equipment</strong> including switches and communication infrastructure operating at higher DC voltage levels</p>
<p data-start="2186" data-end="2308">&bull; <strong data-start="2188" data-end="2218">Process control industries</strong> such as chemical, energy, and heavy industry with <strong data-start="2269" data-end="2306">continuous operation requirements</strong></p>
<p data-start="2313" data-end="2419">&bull; <strong data-start="2315" data-end="2353">Machine building and OEM equipment</strong> where <strong data-start="2360" data-end="2405">compact, high-efficiency power conversion</strong> is critical</p>
<hr data-start="2421" data-end="2426">
<h3 data-section-id="v8w2hq" data-start="2427" data-end="2443">Advantages</h3>
<p data-start="2445" data-end="2568">&bull; <strong data-start="2447" data-end="2482">Three-phase AC input capability</strong> ensures stable operation and balanced load distribution in industrial power systems</p>
<p data-start="2573" data-end="2672">&bull; <strong data-start="2575" data-end="2608">Wide output range (48&ndash;56V DC)</strong> supports applications requiring higher DC voltage flexibility</p>
<p data-start="2677" data-end="2779">&bull; <strong data-start="2679" data-end="2705">High efficiency design</strong> minimizes energy loss and reduces heat generation within control panels</p>
<p data-start="2784" data-end="2884">&bull; <strong data-start="2786" data-end="2812">Spring-clamp terminals</strong> provide fast, vibration-resistant wiring and reduce installation time</p>
<p data-start="2889" data-end="2976">&bull; <strong data-start="2891" data-end="2918">Compact DIN rail design</strong> optimizes panel space and simplifies system integration</p>
<p data-start="2981" data-end="3081">&bull; <strong data-start="2983" data-end="3020">Comprehensive protection features</strong> enhance operational safety and protect connected equipment</p>
</body></html>
<p><a href="https://www.excellentplc.com/allen-bradley-1606-xls480f-3-power-supply/">Allen Bradley 1606-XLS480F-3 Power Supply</a>最先出现在<a href="https://www.excellentplc.com">Excellent PLC</a>。</p>
]]></content:encoded>
					
					<wfw:commentRss>https://www.excellentplc.com/allen-bradley-1606-xls480f-3-power-supply/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
	</channel>
</rss>
