<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>1738-IE2VM12 - Excellent PLC</title>
	<atom:link href="https://www.excellentplc.com/tag/1738-ie2vm12/feed/" rel="self" type="application/rss+xml" />
	<link>https://www.excellentplc.com/tag/1738-ie2vm12/</link>
	<description></description>
	<lastBuildDate>Thu, 16 Apr 2026 07:38:39 +0000</lastBuildDate>
	<language>zh-Hans</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.9.4</generator>

<image>
	<url>https://www.excellentplc.com/wp-content/uploads/2025/08/cropped-cropped-logo-192x192-1-32x32.jpg</url>
	<title>1738-IE2VM12 - Excellent PLC</title>
	<link>https://www.excellentplc.com/tag/1738-ie2vm12/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Allen Bradley 1738-IE2VM12 ArmorPoint Analog Input Module</title>
		<link>https://www.excellentplc.com/allen-bradley-1738-ie2vm12-armorpoint-analog-input-module/</link>
					<comments>https://www.excellentplc.com/allen-bradley-1738-ie2vm12-armorpoint-analog-input-module/#respond</comments>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Thu, 16 Apr 2026 07:37:04 +0000</pubDate>
				<category><![CDATA[Allen Bradley]]></category>
		<category><![CDATA[1738-IE2VM12]]></category>
		<category><![CDATA[Allen Bradley 1738-IE2VM12]]></category>
		<category><![CDATA[ArmorPoint Analog Input Module]]></category>
		<guid isPermaLink="false">https://www.excellentplc.com/?p=127311</guid>

					<description><![CDATA[<p>Product Introduction The Allen Bradley 1738-IE2VM12 Arm [&#8230;]</p>
<p><a href="https://www.excellentplc.com/allen-bradley-1738-ie2vm12-armorpoint-analog-input-module/">Allen Bradley 1738-IE2VM12 ArmorPoint Analog Input Module</a>最先出现在<a href="https://www.excellentplc.com">Excellent PLC</a>。</p>
]]></description>
										<content:encoded><![CDATA[<!DOCTYPE html PUBLIC "-//W3C//DTD HTML 4.0 Transitional//EN" "http://www.w3.org/TR/REC-html40/loose.dtd">
<html><body><h3 data-section-id="wmrafh" data-start="4" data-end="28"><img fetchpriority="high" decoding="async" class="alignnone size-full wp-image-127313" src="https://www.excellentplc.com/wp-content/uploads/2026/04/1738-IE2VM12-1-1.jpg" alt="Allen Bradley 1738-IE2VM12 ArmorPoint Analog Input Module" width="800" height="800"></h3>
<h3 data-section-id="wmrafh" data-start="4" data-end="28">Product Introduction</h3>
<p data-start="29" data-end="418">The Allen Bradley 1738-IE2VM12 ArmorPoint Analog Input Module is a compact and rugged analog input module designed for the ArmorPoint I/O platform from <span class="hover:entity-accent entity-underline inline cursor-pointer align-baseline"><span class="whitespace-normal">Rockwell Automation</span></span>. It provides two single-ended analog input channels and is engineered for accurate signal acquisition in harsh industrial environments where traditional cabinet-based I/O solutions are not practical.</p>
<p data-start="420" data-end="744">This module is built with a fully sealed enclosure and high ingress protection, allowing it to be mounted directly on machines or in exposed field locations. Its design significantly reduces wiring complexity and eliminates the need for additional protective enclosures, making it ideal for decentralized automation systems.</p>
<p data-start="746" data-end="1065">The 1738-IE2VM12 supports flexible configuration through a keyswitch mechanism, enabling quick setup and reliable operation. With stable performance and precise signal handling, it is well suited for applications requiring continuous monitoring of analog variables such as voltage signals from sensors and transmitters.</p>
<hr data-start="1067" data-end="1070">
<h3 data-section-id="1dqbs77" data-start="1071" data-end="1097">Product Specifications</h3>
<div class="TyagGW_tableContainer">
<div class="group TyagGW_tableWrapper flex flex-col-reverse w-fit" tabindex="-1">
<table class="w-fit min-w-(--thread-content-width)" data-start="1098" data-end="1909">
<thead data-start="1098" data-end="1123">
<tr data-start="1098" data-end="1123">
<th class="" data-start="1098" data-end="1114" data-col-size="sm"><strong data-start="1100" data-end="1113">Parameter</strong></th>
<th class="" data-start="1114" data-end="1123" data-col-size="md">Value</th>
</tr>
</thead>
<tbody data-start="1149" data-end="1909">
<tr data-start="1149" data-end="1201">
<td data-start="1149" data-end="1167" data-col-size="sm"><strong data-start="1151" data-end="1166">Module Type</strong></td>
<td data-start="1167" data-end="1201" data-col-size="md">ArmorPoint Analog Input Module</td>
</tr>
<tr data-start="1202" data-end="1239">
<td data-start="1202" data-end="1225" data-col-size="sm"><strong data-start="1204" data-end="1224">Number of Inputs</strong></td>
<td data-start="1225" data-end="1239" data-col-size="md">2 Channels</td>
</tr>
<tr data-start="1240" data-end="1282">
<td data-start="1240" data-end="1266" data-col-size="sm"><strong data-start="1242" data-end="1265">Input Configuration</strong></td>
<td data-start="1266" data-end="1282" data-col-size="md">Single-ended</td>
</tr>
<tr data-start="1283" data-end="1325">
<td data-start="1283" data-end="1307" data-col-size="sm"><strong data-start="1285" data-end="1306">Input Signal Type</strong></td>
<td data-start="1307" data-end="1325" data-col-size="md">Analog Voltage</td>
</tr>
<tr data-start="1326" data-end="1366">
<td data-start="1326" data-end="1351" data-col-size="sm"><strong data-start="1328" data-end="1350">Keyswitch Position</strong></td>
<td data-start="1351" data-end="1366" data-col-size="md">3 Positions</td>
</tr>
<tr data-start="1367" data-end="1399">
<td data-start="1367" data-end="1390" data-col-size="sm"><strong data-start="1369" data-end="1389">POINTBus Current</strong></td>
<td data-start="1390" data-end="1399" data-col-size="md">75 mA</td>
</tr>
<tr data-start="1400" data-end="1434">
<td data-start="1400" data-end="1424" data-col-size="sm"><strong data-start="1402" data-end="1423">Power Consumption</strong></td>
<td data-start="1424" data-end="1434" data-col-size="md">0.75 W</td>
</tr>
<tr data-start="1435" data-end="1475">
<td data-start="1435" data-end="1457" data-col-size="sm"><strong data-start="1437" data-end="1456">Connection Type</strong></td>
<td data-start="1457" data-end="1475" data-col-size="md">M12 Connectors</td>
</tr>
<tr data-start="1476" data-end="1509">
<td data-start="1476" data-end="1500" data-col-size="sm"><strong data-start="1478" data-end="1499">Protection Rating</strong></td>
<td data-start="1500" data-end="1509" data-col-size="md">IP69K</td>
</tr>
<tr data-start="1510" data-end="1556">
<td data-start="1510" data-end="1528" data-col-size="sm"><strong data-start="1512" data-end="1527">Design Type</strong></td>
<td data-start="1528" data-end="1556" data-col-size="md">Sealed, On-machine Mount</td>
</tr>
<tr data-start="1557" data-end="1607">
<td data-start="1557" data-end="1573" data-col-size="sm"><strong data-start="1559" data-end="1572">Isolation</strong></td>
<td data-start="1573" data-end="1607" data-col-size="md">Electrical isolation supported</td>
</tr>
<tr data-start="1608" data-end="1674">
<td data-start="1608" data-end="1628" data-col-size="sm"><strong data-start="1610" data-end="1627">Mounting Type</strong></td>
<td data-start="1628" data-end="1674" data-col-size="md">Direct Machine Mount / DIN Rail Compatible</td>
</tr>
<tr data-start="1675" data-end="1718">
<td data-start="1675" data-end="1703" data-col-size="sm"><strong data-start="1677" data-end="1702">Operating Temperature</strong></td>
<td data-start="1703" data-end="1718" data-col-size="md">-20 to 60&deg;C</td>
</tr>
<tr data-start="1719" data-end="1760">
<td data-start="1719" data-end="1745" data-col-size="sm"><strong data-start="1721" data-end="1744">Storage Temperature</strong></td>
<td data-start="1745" data-end="1760" data-col-size="md">-40 to 85&deg;C</td>
</tr>
<tr data-start="1761" data-end="1809">
<td data-start="1761" data-end="1785" data-col-size="sm"><strong data-start="1763" data-end="1784">Relative Humidity</strong></td>
<td data-start="1785" data-end="1809" data-col-size="md">5&ndash;95% non-condensing</td>
</tr>
<tr data-start="1810" data-end="1846">
<td data-start="1810" data-end="1831" data-col-size="sm"><strong data-start="1812" data-end="1830">Certifications</strong></td>
<td data-start="1831" data-end="1846" data-col-size="md">CE, UL, CSA</td>
</tr>
<tr data-start="1847" data-end="1884">
<td data-start="1847" data-end="1864" data-col-size="sm"><strong data-start="1849" data-end="1863">Dimensions</strong></td>
<td data-start="1864" data-end="1884" data-col-size="md">120 x 42 x 72 mm</td>
</tr>
<tr data-start="1885" data-end="1909">
<td data-start="1885" data-end="1898" data-col-size="sm"><strong data-start="1887" data-end="1897">Weight</strong></td>
<td data-start="1898" data-end="1909" data-col-size="md">0.29 kg</td>
</tr>
</tbody>
</table>
</div>
</div>
<hr data-start="1911" data-end="1914">
<h3 data-section-id="wggvqn" data-start="1915" data-end="1931">Applications</h3>
<p data-start="1933" data-end="2029">&#9679; Used in <strong data-start="1943" data-end="1972">analog signal acquisition</strong>, such as voltage signals from sensors and transmitters</p>
<p data-start="2031" data-end="2144">&#9679; Suitable for <strong data-start="2046" data-end="2074">on-machine installations</strong> in harsh industrial environments with exposure to moisture and dust</p>
<p data-start="2146" data-end="2247">&#9679; Applied in <strong data-start="2159" data-end="2189">process monitoring systems</strong>, including temperature, pressure, and level measurement</p>
<p data-start="2249" data-end="2349">&#9679; Ideal for <strong data-start="2261" data-end="2304">packaging and material handling systems</strong>, requiring continuous analog data feedback</p>
<p data-start="2351" data-end="2445">&#9679; Common in <strong data-start="2363" data-end="2401">automotive and manufacturing lines</strong>, supporting distributed I/O architectures</p>
<p data-start="2447" data-end="2546">&#9679; Used in <strong data-start="2457" data-end="2493">outdoor or washdown environments</strong>, where sealed modules ensure long-term reliability</p>
<hr data-start="2548" data-end="2551">
<h3 data-section-id="1l3n95q" data-start="2552" data-end="2566">Advantages</h3>
<p data-start="2568" data-end="2671">&#9679; Fully sealed housing with <strong data-start="2596" data-end="2616">IP69K protection</strong>, ensuring reliable operation in extreme environments</p>
<p data-start="2673" data-end="2760">&#9679; Provides <strong data-start="2684" data-end="2717">2 high-accuracy analog inputs</strong>, suitable for precise signal measurement</p>
<p data-start="2762" data-end="2853">&#9679; Supports <strong data-start="2773" data-end="2809">single-ended input configuration</strong>, simplifying wiring for many sensor types</p>
<p data-start="2855" data-end="2933">&#9679; Equipped with <strong data-start="2871" data-end="2898">keyswitch configuration</strong>, allowing quick and secure setup</p>
<p data-start="2935" data-end="3023">&#9679; Enables <strong data-start="2945" data-end="2968">on-machine mounting</strong>, reducing installation cost and cabinet requirements</p>
<p data-start="3025" data-end="3103">&#9679; Compact design with <strong data-start="3047" data-end="3072">low power consumption</strong>, improving system efficiency</p>
</body></html>
<p><a href="https://www.excellentplc.com/allen-bradley-1738-ie2vm12-armorpoint-analog-input-module/">Allen Bradley 1738-IE2VM12 ArmorPoint Analog Input Module</a>最先出现在<a href="https://www.excellentplc.com">Excellent PLC</a>。</p>
]]></content:encoded>
					
					<wfw:commentRss>https://www.excellentplc.com/allen-bradley-1738-ie2vm12-armorpoint-analog-input-module/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
	</channel>
</rss>