<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>1746-IM8/A - Excellent PLC</title>
	<atom:link href="https://www.excellentplc.com/tag/1746-im8-a/feed/" rel="self" type="application/rss+xml" />
	<link>https://www.excellentplc.com/tag/1746-im8-a/</link>
	<description></description>
	<lastBuildDate>Fri, 17 Apr 2026 01:34:47 +0000</lastBuildDate>
	<language>zh-Hans</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.9.4</generator>

<image>
	<url>https://www.excellentplc.com/wp-content/uploads/2025/08/cropped-cropped-logo-192x192-1-32x32.jpg</url>
	<title>1746-IM8/A - Excellent PLC</title>
	<link>https://www.excellentplc.com/tag/1746-im8-a/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Allen Bradley 1746-IM8/A SLC 500 AC Digital Input Module</title>
		<link>https://www.excellentplc.com/allen-bradley-1746-im8-a-slc-500-ac-digital-input-module/</link>
					<comments>https://www.excellentplc.com/allen-bradley-1746-im8-a-slc-500-ac-digital-input-module/#respond</comments>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Fri, 17 Apr 2026 01:34:47 +0000</pubDate>
				<category><![CDATA[Allen Bradley]]></category>
		<category><![CDATA[1746-IM8/A]]></category>
		<category><![CDATA[Allen Bradley 1746-IM8/A]]></category>
		<category><![CDATA[SLC 500 AC Digital Input Module]]></category>
		<guid isPermaLink="false">https://www.excellentplc.com/?p=127404</guid>

					<description><![CDATA[<p>Product Introduction The Allen-Bradley 1746-IM8/A is an [&#8230;]</p>
<p><a href="https://www.excellentplc.com/allen-bradley-1746-im8-a-slc-500-ac-digital-input-module/">Allen Bradley 1746-IM8/A SLC 500 AC Digital Input Module</a>最先出现在<a href="https://www.excellentplc.com">Excellent PLC</a>。</p>
]]></description>
										<content:encoded><![CDATA[<!DOCTYPE html PUBLIC "-//W3C//DTD HTML 4.0 Transitional//EN" "http://www.w3.org/TR/REC-html40/loose.dtd">
<html><body><h3 data-section-id="kz71jh" data-start="6" data-end="32"><img fetchpriority="high" decoding="async" class="alignnone size-full wp-image-127410" src="https://www.excellentplc.com/wp-content/uploads/2026/04/1746-IM8-A-1-1.jpg" alt="Allen Bradley 1746-IM8/A SLC 500 AC Digital Input Module" width="800" height="800"></h3>
<h3 data-section-id="kz71jh" data-start="6" data-end="32">Product Introduction</h3>
<p data-start="34" data-end="402">The Allen-Bradley 1746-IM8/A is an AC digital input module designed for the SLC 500 programmable controller platform, specifically intended for higher voltage input applications. As a Series A module, it provides stable and reliable acquisition of 200&ndash;250V AC field signals, making it suitable for industrial environments where higher voltage control systems are used.</p>
<p data-start="404" data-end="750">This module features 8 input channels, allowing it to monitor multiple field devices simultaneously. It is commonly used to interface with high-voltage AC devices such as industrial switches, relays, and contactors. The module converts these field signals into logic-level inputs that can be processed by the PLC for control and monitoring tasks.</p>
<p data-start="752" data-end="1070">Engineered for seamless integration into SLC 500 chassis systems, the 1746-IM8/A maintains compatibility with existing infrastructure while delivering consistent performance. Its design emphasizes electrical robustness, ensuring reliable operation even in environments with voltage fluctuations and electrical noise.</p>
<hr data-start="1072" data-end="1077">
<h3 data-section-id="vum7lv" data-start="1078" data-end="1106">Product Specifications</h3>
<div class="TyagGW_tableContainer">
<div class="group TyagGW_tableWrapper flex flex-col-reverse w-fit" tabindex="-1">
<table class="w-fit min-w-(--thread-content-width)" data-start="1108" data-end="2019">
<thead data-start="1108" data-end="1139">
<tr data-start="1108" data-end="1139">
<th class="" data-start="1108" data-end="1124" data-col-size="sm"><strong data-start="1110" data-end="1123">Parameter</strong></th>
<th class="" data-start="1124" data-end="1139" data-col-size="sm">Description</th>
</tr>
</thead>
<tbody data-start="1171" data-end="2019">
<tr data-start="1171" data-end="1231">
<td data-start="1171" data-end="1190" data-col-size="sm"><strong data-start="1173" data-end="1189">Manufacturer</strong></td>
<td data-start="1190" data-end="1231" data-col-size="sm"><span class="hover:entity-accent entity-underline inline cursor-pointer align-baseline"><span class="whitespace-normal">Allen-Bradley</span></span></td>
</tr>
<tr data-start="1232" data-end="1256">
<td data-start="1232" data-end="1245" data-col-size="sm"><strong data-start="1234" data-end="1244">Series</strong></td>
<td data-start="1245" data-end="1256" data-col-size="sm">SLC 500</td>
</tr>
<tr data-start="1257" data-end="1302">
<td data-start="1257" data-end="1275" data-col-size="sm"><strong data-start="1259" data-end="1274">Module Type</strong></td>
<td data-start="1275" data-end="1302" data-col-size="sm">AC Digital Input Module</td>
</tr>
<tr data-start="1303" data-end="1338">
<td data-start="1303" data-end="1324" data-col-size="sm"><strong data-start="1305" data-end="1323">Catalog Number</strong></td>
<td data-start="1324" data-end="1338" data-col-size="sm">1746-IM8/A</td>
</tr>
<tr data-start="1339" data-end="1399">
<td data-start="1339" data-end="1367" data-col-size="sm"><strong data-start="1341" data-end="1366">Module Classification</strong></td>
<td data-start="1367" data-end="1399" data-col-size="sm">High Voltage AC Input Module</td>
</tr>
<tr data-start="1400" data-end="1437">
<td data-start="1400" data-end="1425" data-col-size="sm"><strong data-start="1402" data-end="1424">Number of Channels</strong></td>
<td data-start="1425" data-end="1437" data-col-size="sm">8 Inputs</td>
</tr>
<tr data-start="1438" data-end="1479">
<td data-start="1438" data-end="1464" data-col-size="sm"><strong data-start="1440" data-end="1463">Input Voltage Range</strong></td>
<td data-start="1464" data-end="1479" data-col-size="sm">170&ndash;265V AC</td>
</tr>
<tr data-start="1480" data-end="1517">
<td data-start="1480" data-end="1502" data-col-size="sm"><strong data-start="1482" data-end="1501">Nominal Voltage</strong></td>
<td data-start="1502" data-end="1517" data-col-size="sm">200&ndash;250V AC</td>
</tr>
<tr data-start="1518" data-end="1552">
<td data-start="1518" data-end="1540" data-col-size="sm"><strong data-start="1520" data-end="1539">Input Frequency</strong></td>
<td data-start="1540" data-end="1552" data-col-size="sm">50/60 Hz</td>
</tr>
<tr data-start="1553" data-end="1605">
<td data-start="1553" data-end="1573" data-col-size="sm"><strong data-start="1555" data-end="1572">Input Current</strong></td>
<td data-start="1573" data-end="1605" data-col-size="sm">Approx. 10&ndash;12 mA per channel</td>
</tr>
<tr data-start="1606" data-end="1646">
<td data-start="1606" data-end="1635" data-col-size="sm"><strong data-start="1608" data-end="1634">Signal Filtering Delay</strong></td>
<td data-start="1635" data-end="1646" data-col-size="sm">8&ndash;12 ms</td>
</tr>
<tr data-start="1647" data-end="1697">
<td data-start="1647" data-end="1663" data-col-size="sm"><strong data-start="1649" data-end="1662">Isolation</strong></td>
<td data-start="1663" data-end="1697" data-col-size="sm">1500V RMS (Backplane to Field)</td>
</tr>
<tr data-start="1698" data-end="1753">
<td data-start="1698" data-end="1734" data-col-size="sm"><strong data-start="1700" data-end="1733">Backplane Current Consumption</strong></td>
<td data-start="1734" data-end="1753" data-col-size="sm">Approx. 0.085 A</td>
</tr>
<tr data-start="1754" data-end="1795">
<td data-start="1754" data-end="1782" data-col-size="sm"><strong data-start="1756" data-end="1781">Operating Temperature</strong></td>
<td data-start="1782" data-end="1795" data-col-size="sm">0 to 60&deg;C</td>
</tr>
<tr data-start="1796" data-end="1837">
<td data-start="1796" data-end="1822" data-col-size="sm"><strong data-start="1798" data-end="1821">Storage Temperature</strong></td>
<td data-start="1822" data-end="1837" data-col-size="sm">-40 to 85&deg;C</td>
</tr>
<tr data-start="1838" data-end="1876">
<td data-start="1838" data-end="1857" data-col-size="sm"><strong data-start="1840" data-end="1856">Installation</strong></td>
<td data-start="1857" data-end="1876" data-col-size="sm">SLC 500 Chassis</td>
</tr>
<tr data-start="1877" data-end="1913">
<td data-start="1877" data-end="1899" data-col-size="sm"><strong data-start="1879" data-end="1898">Wiring Category</strong></td>
<td data-start="1899" data-end="1913" data-col-size="sm">Category 1</td>
</tr>
<tr data-start="1914" data-end="1947">
<td data-start="1914" data-end="1935" data-col-size="sm"><strong data-start="1916" data-end="1934">Series Version</strong></td>
<td data-start="1935" data-end="1947" data-col-size="sm">Series A</td>
</tr>
<tr data-start="1948" data-end="1993">
<td data-start="1948" data-end="1965" data-col-size="sm"><strong data-start="1950" data-end="1964">Dimensions</strong></td>
<td data-start="1965" data-end="1993" data-col-size="sm">144.5 &times; 34.6 &times; 130.18 mm</td>
</tr>
<tr data-start="1994" data-end="2019">
<td data-start="1994" data-end="2007" data-col-size="sm"><strong data-start="1996" data-end="2006">Weight</strong></td>
<td data-start="2007" data-end="2019" data-col-size="sm">0.181 kg</td>
</tr>
</tbody>
</table>
</div>
</div>
<hr data-start="2021" data-end="2026">
<h3 data-section-id="17tovxr" data-start="2027" data-end="2045">Applications</h3>
<p data-start="2050" data-end="2205">&#9679; <strong data-start="2052" data-end="2083">High-Voltage Control Panels</strong><br data-start="2083" data-end="2086">Used for monitoring 200&ndash;250V AC signals from industrial control devices such as selector switches and relay contacts.</p>
<p data-start="2210" data-end="2353">&#9679; <strong data-start="2212" data-end="2242">Heavy Industrial Equipment</strong><br data-start="2242" data-end="2245">Suitable for applications involving high-voltage machinery where standard 120V modules are not applicable.</p>
<p data-start="2358" data-end="2522">&#9679; <strong data-start="2360" data-end="2390">Process Automation Systems</strong><br data-start="2390" data-end="2393">Applied in industries such as power generation, metallurgy, and chemical processing where higher AC voltage signals are common.</p>
<p data-start="2527" data-end="2676">&#9679; <strong data-start="2529" data-end="2554">Motor Control Systems</strong><br data-start="2554" data-end="2557">Detects status signals from motor starters, contactors, and protection devices operating at higher AC voltage levels.</p>
<p data-start="2681" data-end="2860">&#9679; <strong data-start="2683" data-end="2716">System Upgrades and Expansion</strong><br data-start="2716" data-end="2719">Provides a direct solution for integrating high-voltage input signals into existing SLC 500 systems without additional conversion hardware.</p>
<hr data-start="2862" data-end="2867">
<h3 data-section-id="v8w2hq" data-start="2868" data-end="2884">Advantages</h3>
<p data-start="2889" data-end="3044">&#9679; <strong data-start="2891" data-end="2926">Designed for 200&ndash;250V AC Inputs</strong><br data-start="2926" data-end="2929">Optimized for higher voltage ranges, eliminating the need for external step-down interfaces in many applications.</p>
<p data-start="3049" data-end="3178">&#9679; <strong data-start="3051" data-end="3082">Strong Electrical Isolation</strong><br data-start="3082" data-end="3085">Ensures protection between field wiring and PLC backplane, improving overall system safety.</p>
<p data-start="3183" data-end="3299">&#9679; <strong data-start="3185" data-end="3214">Noise-Resistant Operation</strong><br data-start="3214" data-end="3217">Internal filtering minimizes false triggering caused by electrical disturbances.</p>
<p data-start="3304" data-end="3425">&#9679; <strong data-start="3306" data-end="3337">Compact Rack-Mounted Design</strong><br data-start="3337" data-end="3340">Integrates directly into SLC 500 chassis, simplifying installation and maintenance.</p>
<p data-start="3430" data-end="3545">&#9679; <strong data-start="3432" data-end="3464">Consistent Signal Processing</strong><br data-start="3464" data-end="3467">Provides stable input recognition even under fluctuating voltage conditions.</p>
<p data-start="3550" data-end="3675">&#9679; <strong data-start="3552" data-end="3587">Reliable Industrial Performance</strong><br data-start="3587" data-end="3590">Proven durability in demanding environments with continuous operation requirements.</p>
</body></html>
<p><a href="https://www.excellentplc.com/allen-bradley-1746-im8-a-slc-500-ac-digital-input-module/">Allen Bradley 1746-IM8/A SLC 500 AC Digital Input Module</a>最先出现在<a href="https://www.excellentplc.com">Excellent PLC</a>。</p>
]]></content:encoded>
					
					<wfw:commentRss>https://www.excellentplc.com/allen-bradley-1746-im8-a-slc-500-ac-digital-input-module/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
	</channel>
</rss>
