<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>330909-00-80-10-02-CN - Excellent PLC</title>
	<atom:link href="https://www.excellentplc.com/tag/330909-00-80-10-02-cn/feed/" rel="self" type="application/rss+xml" />
	<link>https://www.excellentplc.com/tag/330909-00-80-10-02-cn/</link>
	<description></description>
	<lastBuildDate>Tue, 21 Oct 2025 08:55:28 +0000</lastBuildDate>
	<language>zh-Hans</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.9.4</generator>

<image>
	<url>https://www.excellentplc.com/wp-content/uploads/2025/08/cropped-cropped-logo-192x192-1-32x32.jpg</url>
	<title>330909-00-80-10-02-CN - Excellent PLC</title>
	<link>https://www.excellentplc.com/tag/330909-00-80-10-02-cn/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Bently Nevada 330909-00-80-10-02-CN 3300 NSv Proximity Probe</title>
		<link>https://www.excellentplc.com/bently-nevada-330909-00-80-10-02-cn-3300-nsv-proximity-probe/</link>
		
		<dc:creator><![CDATA[wang]]></dc:creator>
		<pubDate>Tue, 21 Oct 2025 08:55:28 +0000</pubDate>
				<category><![CDATA[Bently Nevada]]></category>
		<category><![CDATA[3300 NSv Proximity Probe]]></category>
		<category><![CDATA[330909-00-80-10-02-CN]]></category>
		<category><![CDATA[Bently Nevada 330909-00-80-10-02-CN]]></category>
		<guid isPermaLink="false">https://www.excellentplc.com/?p=107160</guid>

					<description><![CDATA[<p>Product Overview The Bently Nevada 330909-00-80-10-02-C [&#8230;]</p>
<p><a href="https://www.excellentplc.com/bently-nevada-330909-00-80-10-02-cn-3300-nsv-proximity-probe/">Bently Nevada 330909-00-80-10-02-CN 3300 NSv Proximity Probe</a>最先出现在<a href="https://www.excellentplc.com">Excellent PLC</a>。</p>
]]></description>
										<content:encoded><![CDATA[<!DOCTYPE html PUBLIC "-//W3C//DTD HTML 4.0 Transitional//EN" "http://www.w3.org/TR/REC-html40/loose.dtd">
<html><body><h3 data-start="347" data-end="371"><img fetchpriority="high" decoding="async" class="size-full wp-image-107161 aligncenter" src="https://www.excellentplc.com/wp-content/uploads/2025/10/330909-00-80-10-02-CN-1.jpg" alt="Bently Nevada 330909-00-80-10-02-CN 3300 NSv Proximity Probe" width="800" height="800"></h3>
<h3 data-start="347" data-end="371"><strong data-start="351" data-end="371">Product Overview</strong></h3>
<p data-start="373" data-end="726">The <strong data-start="377" data-end="416">Bently Nevada 330909-00-80-10-02-CN</strong> is a high-precision <strong data-start="437" data-end="465">3300 NSv Proximity Probe</strong> designed for accurate monitoring of shaft displacement and vibration in critical rotating machinery. It provides stable and reliable measurements under harsh industrial conditions and is fully compatible with Bently Nevada 3300 XL and NSv monitoring systems.</p>
<hr data-start="965" data-end="968">
<h3 data-start="970" data-end="990"><strong data-start="974" data-end="990">Key Features</strong></h3>
<ul data-start="992" data-end="1457">
<li data-start="992" data-end="1057">
<p data-start="994" data-end="1057">High-accuracy measurement of shaft displacement and vibration</p>
</li>
<li data-start="1058" data-end="1112">
<p data-start="1060" data-end="1112">Compatible with 3300 XL and NSv monitoring systems</p>
</li>
<li data-start="1113" data-end="1175">
<p data-start="1115" data-end="1175">Non-contact eddy-current sensing for long-term reliability</p>
</li>
<li data-start="1176" data-end="1265">
<p data-start="1178" data-end="1265">Industrial-grade construction resistant to shock, vibration, and temperature extremes</p>
</li>
<li data-start="1266" data-end="1313">
<p data-start="1268" data-end="1313">
</p></li>
</ul>
<hr data-start="1459" data-end="1462">
<h3 data-start="1464" data-end="1496"><strong data-start="1468" data-end="1496">Technical Specifications</strong></h3>
<div class="_tableContainer_1rjym_1">
<div class="group _tableWrapper_1rjym_13 flex w-fit flex-col-reverse" tabindex="-1">
<table class="w-fit min-w-(--thread-content-width)" data-start="1498" data-end="3040">
<thead data-start="1498" data-end="1587">
<tr data-start="1498" data-end="1587">
<th data-start="1498" data-end="1532" data-col-size="sm"><strong data-start="1500" data-end="1517">Specification</strong></th>
<th data-start="1532" data-end="1587" data-col-size="sm"><strong data-start="1534" data-end="1545">Details</strong></th>
</tr>
</thead>
<tbody data-start="1678" data-end="3040">
<tr data-start="1678" data-end="1768">
<td data-start="1678" data-end="1713" data-col-size="sm"><strong data-start="1680" data-end="1689">Model</strong></td>
<td data-start="1713" data-end="1768" data-col-size="sm">330909-00-80-10-02-CN</td>
</tr>
<tr data-start="1769" data-end="1860">
<td data-start="1769" data-end="1804" data-col-size="sm"><strong data-start="1771" data-end="1779">Type</strong></td>
<td data-start="1804" data-end="1860" data-col-size="sm">3300 NSv Proximity Probe</td>
</tr>
<tr data-start="1861" data-end="1950">
<td data-start="1861" data-end="1896" data-col-size="sm"><strong data-start="1863" data-end="1883">Measurement Type</strong></td>
<td data-start="1896" data-end="1950" data-col-size="sm">Shaft displacement / vibration</td>
</tr>
<tr data-start="1951" data-end="2041">
<td data-start="1951" data-end="1986" data-col-size="sm"><strong data-start="1953" data-end="1973">Sensor Principle</strong></td>
<td data-start="1986" data-end="2041" data-col-size="sm">Eddy-current (non-contact)</td>
</tr>
<tr data-start="2042" data-end="2133">
<td data-start="2042" data-end="2078" data-col-size="sm"><strong data-start="2044" data-end="2066">Probe Tip Material</strong></td>
<td data-start="2078" data-end="2133" data-col-size="sm">Stainless steel</td>
</tr>
<tr data-start="2134" data-end="2225">
<td data-start="2134" data-end="2169" data-col-size="sm"><strong data-start="2136" data-end="2151">Probe Cable</strong></td>
<td data-start="2169" data-end="2225" data-col-size="sm">Shielded coaxial cable</td>
</tr>
<tr data-start="2226" data-end="2315">
<td data-start="2226" data-end="2261" data-col-size="sm"><strong data-start="2228" data-end="2250">Frequency Response</strong></td>
<td data-start="2261" data-end="2315" data-col-size="sm">0&ndash;10 kHz</td>
</tr>
<tr data-start="2316" data-end="2405">
<td data-start="2316" data-end="2351" data-col-size="sm"><strong data-start="2318" data-end="2333">Sensitivity</strong></td>
<td data-start="2351" data-end="2405" data-col-size="sm">50 mV/mil</td>
</tr>
<tr data-start="2406" data-end="2496">
<td data-start="2406" data-end="2441" data-col-size="sm"><strong data-start="2408" data-end="2433">Operating Temperature</strong></td>
<td data-start="2441" data-end="2496" data-col-size="sm">&ndash;40 &deg;C to +120 &deg;C</td>
</tr>
<tr data-start="2497" data-end="2587">
<td data-start="2497" data-end="2532" data-col-size="sm"><strong data-start="2499" data-end="2522">Storage Temperature</strong></td>
<td data-start="2532" data-end="2587" data-col-size="sm">&ndash;40 &deg;C to +125 &deg;C</td>
</tr>
<tr data-start="2588" data-end="2677">
<td data-start="2588" data-end="2623" data-col-size="sm"><strong data-start="2590" data-end="2615">Insulation Resistance</strong></td>
<td data-start="2623" data-end="2677" data-col-size="sm">&gt; 100 M&Omega;</td>
</tr>
<tr data-start="2678" data-end="2767">
<td data-start="2678" data-end="2713" data-col-size="sm"><strong data-start="2680" data-end="2704">Probe Shaft Diameter</strong></td>
<td data-start="2713" data-end="2767" data-col-size="sm">8 mm</td>
</tr>
<tr data-start="2768" data-end="2857">
<td data-start="2768" data-end="2803" data-col-size="sm"><strong data-start="2770" data-end="2786">Probe Length</strong></td>
<td data-start="2803" data-end="2857" data-col-size="sm">80 mm</td>
</tr>
<tr data-start="2858" data-end="2948">
<td data-start="2858" data-end="2893" data-col-size="sm"><strong data-start="2860" data-end="2886">Dimensions</strong></td>
<td data-start="2893" data-end="2948" data-col-size="sm">Total Length : 1.0 meter</td>
</tr>
<tr data-start="2949" data-end="3040">
<td data-start="2949" data-end="2984" data-col-size="sm"><strong data-start="2951" data-end="2961">Weight</strong></td>
<td data-start="2984" data-end="3040" data-col-size="sm">0.15 kg</td>
</tr>
</tbody>
</table>
</div>
</div>
<hr data-start="3042" data-end="3045">
<h3 data-start="3047" data-end="3087"><strong data-start="3051" data-end="3087">Frequently Asked Questions (FAQ)</strong></h3>
<p data-start="3089" data-end="3242"><strong data-start="3089" data-end="3160">1. What is the primary function of the 330909-00-80-10-02-CN probe?</strong><br data-start="3160" data-end="3163">It measures shaft displacement and vibration for critical rotating machinery.</p>
<p data-start="3244" data-end="3376"><strong data-start="3244" data-end="3297">2. Is this probe compatible with 3300 XL systems?</strong><br data-start="3297" data-end="3300">Yes, it works fully with Bently Nevada 3300 XL and NSv monitoring systems.</p>
<p data-start="3378" data-end="3471"><strong data-start="3378" data-end="3415">3. What is the probe tip made of?</strong><br data-start="3415" data-end="3418">The probe tip is made from durable stainless steel.</p>
<p data-start="3473" data-end="3595"><strong data-start="3473" data-end="3524">4. What type of sensing technology does it use?</strong><br data-start="3524" data-end="3527">It uses non-contact eddy-current sensing for precise measurements.</p>
<p data-start="3597" data-end="3682"><strong data-start="3597" data-end="3641">5. What is the frequency response range?</strong><br data-start="3641" data-end="3644">The probe responds from 0 to 10 kHz.</p>
<p data-start="3684" data-end="3808"><strong data-start="3684" data-end="3730">6. Can it operate in extreme temperatures?</strong><br data-start="3730" data-end="3733">Yes, the operating range is &ndash;40 &deg;C to +120 &deg;C, and storage up to +125 &deg;C.</p>
<p data-start="3810" data-end="3918"><strong data-start="3810" data-end="3864">7. What is the insulation resistance of the probe?</strong><br data-start="3864" data-end="3867">The insulation resistance is greater than 100 M&Omega;.</p>
<p data-start="3920" data-end="4085"><strong data-start="3920" data-end="3979">8. How is the probe connected to the monitoring system?</strong><br data-start="3979" data-end="3982">It connects via a shielded coaxial cable with a gold-plated connector for stable signal transmission.</p>
<hr data-start="4087" data-end="4090">
<h3 data-start="4092" data-end="4128"><strong data-start="4096" data-end="4128">Related Bently Nevada Models</strong></h3>
<div class="_tableContainer_1rjym_1">
<div class="group _tableWrapper_1rjym_13 flex w-fit flex-col-reverse" tabindex="-1">
<table class="w-fit min-w-(--thread-content-width)" data-start="4130" data-end="4738">
<thead data-start="4130" data-end="4205">
<tr data-start="4130" data-end="4205">
<th data-start="4130" data-end="4158" data-col-size="sm"><strong data-start="4132" data-end="4141">Model</strong></th>
<th data-start="4158" data-end="4205" data-col-size="md"><strong data-start="4160" data-end="4175">Description</strong></th>
</tr>
</thead>
<tbody data-start="4283" data-end="4738">
<tr data-start="4283" data-end="4358">
<td data-start="4283" data-end="4312" data-col-size="sm">330909-00-80-10-01-00</td>
<td data-start="4312" data-end="4358" data-col-size="md">3300 NSv Proximity Probe</td>
</tr>
<tr data-start="4359" data-end="4434">
<td data-start="4359" data-end="4388" data-col-size="sm">330909-00-60-10-01-05</td>
<td data-start="4388" data-end="4434" data-col-size="md">3300 NSv Proximity Probe</td>
</tr>
<tr data-start="4435" data-end="4510">
<td data-start="4435" data-end="4464" data-col-size="sm">330909-00-25-10-02-00</td>
<td data-start="4464" data-end="4510" data-col-size="md">3300 NSv Proximity Probe</td>
</tr>
<tr data-start="4511" data-end="4586">
<td data-start="4511" data-end="4540" data-col-size="sm">330908-21-50-10-02-00</td>
<td data-start="4540" data-end="4586" data-col-size="md">3300 NSv Proximity Probe</td>
</tr>
<tr data-start="4587" data-end="4662">
<td data-start="4587" data-end="4616" data-col-size="sm">330904-00-03-10-02-00</td>
<td data-start="4616" data-end="4662" data-col-size="md">3300 NSv Proximity Probe</td>
</tr>
<tr data-start="4663" data-end="4738">
<td data-start="4663" data-end="4692" data-col-size="sm">330910-00-18-10-02-00</td>
<td data-start="4692" data-end="4738" data-col-size="md">3300 NSv Proximity Probe</td>
</tr>
</tbody>
</table>
</div>
</div>
<hr data-start="4740" data-end="4743">
<h3 data-start="4745" data-end="4781"><strong data-start="4749" data-end="4781">Popular Bently Nevada Models</strong></h3>
<div class="_tableContainer_1rjym_1">
<div class="group _tableWrapper_1rjym_13 flex w-fit flex-col-reverse" tabindex="-1">
<table class="w-fit min-w-(--thread-content-width)" data-start="4783" data-end="5397">
<thead data-start="4783" data-end="4858">
<tr data-start="4783" data-end="4858">
<th data-start="4783" data-end="4811" data-col-size="sm"><strong data-start="4785" data-end="4794">Model</strong></th>
<th data-start="4811" data-end="4858" data-col-size="sm"><strong data-start="4813" data-end="4828">Description</strong></th>
</tr>
</thead>
<tbody data-start="4936" data-end="5397">
<tr data-start="4936" data-end="5012">
<td data-start="4936" data-end="4965" data-col-size="sm">330104-01-05-50-02-00</td>
<td data-start="4965" data-end="5012" data-col-size="sm">3300 XL 8 mm Proximity Probe</td>
</tr>
<tr data-start="5013" data-end="5089">
<td data-start="5013" data-end="5042" data-col-size="sm">330104-00-11-50-02-00</td>
<td data-start="5042" data-end="5089" data-col-size="sm">3300 XL 8 mm Proximity Probe</td>
</tr>
<tr data-start="5090" data-end="5166">
<td data-start="5090" data-end="5119" data-col-size="sm">330104-01-05-05-02-05</td>
<td data-start="5119" data-end="5166" data-col-size="sm">3300 XL 8 mm Proximity Probe</td>
</tr>
<tr data-start="5167" data-end="5243">
<td data-start="5167" data-end="5196" data-col-size="sm">330104-00-12-10-02-05</td>
<td data-start="5196" data-end="5243" data-col-size="sm">3300 XL 8 mm Proximity Probe</td>
</tr>
<tr data-start="5244" data-end="5320">
<td data-start="5244" data-end="5273" data-col-size="sm">330104-00-18-10-02-05</td>
<td data-start="5273" data-end="5320" data-col-size="sm">3300 XL 8 mm Proximity Probe</td>
</tr>
<tr data-start="5321" data-end="5397">
<td data-start="5321" data-end="5350" data-col-size="sm">330708-00-20-50-02-05</td>
<td data-start="5350" data-end="5397" data-col-size="sm">3300 XL 11 mm Proximity Probe</td>
</tr>
</tbody>
</table>
</div>
</div>
</body></html>
<p><a href="https://www.excellentplc.com/bently-nevada-330909-00-80-10-02-cn-3300-nsv-proximity-probe/">Bently Nevada 330909-00-80-10-02-CN 3300 NSv Proximity Probe</a>最先出现在<a href="https://www.excellentplc.com">Excellent PLC</a>。</p>