<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Allen Bradley 1734-PDN - Excellent PLC</title>
	<atom:link href="https://www.excellentplc.com/tag/allen-bradley-1734-pdn/feed/" rel="self" type="application/rss+xml" />
	<link>https://www.excellentplc.com/tag/allen-bradley-1734-pdn/</link>
	<description></description>
	<lastBuildDate>Thu, 16 Apr 2026 03:16:47 +0000</lastBuildDate>
	<language>zh-Hans</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.9.4</generator>

<image>
	<url>https://www.excellentplc.com/wp-content/uploads/2025/08/cropped-cropped-logo-192x192-1-32x32.jpg</url>
	<title>Allen Bradley 1734-PDN - Excellent PLC</title>
	<link>https://www.excellentplc.com/tag/allen-bradley-1734-pdn/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Allen Bradley 1734-PDN Point I/O DeviceNet Interface Module</title>
		<link>https://www.excellentplc.com/allen-bradley-1734-pdn-point-i-o-devicenet-interface-module/</link>
					<comments>https://www.excellentplc.com/allen-bradley-1734-pdn-point-i-o-devicenet-interface-module/#respond</comments>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Thu, 16 Apr 2026 03:16:47 +0000</pubDate>
				<category><![CDATA[Allen Bradley]]></category>
		<category><![CDATA[1734-PDN]]></category>
		<category><![CDATA[Allen Bradley 1734-PDN]]></category>
		<category><![CDATA[Point I/O DeviceNet Interface Module]]></category>
		<guid isPermaLink="false">https://www.excellentplc.com/?p=127268</guid>

					<description><![CDATA[<p>Product Introduction The Allen Bradley 1734-PDN Point I [&#8230;]</p>
<p><a href="https://www.excellentplc.com/allen-bradley-1734-pdn-point-i-o-devicenet-interface-module/">Allen Bradley 1734-PDN Point I/O DeviceNet Interface Module</a>最先出现在<a href="https://www.excellentplc.com">Excellent PLC</a>。</p>
]]></description>
										<content:encoded><![CDATA[<!DOCTYPE html PUBLIC "-//W3C//DTD HTML 4.0 Transitional//EN" "http://www.w3.org/TR/REC-html40/loose.dtd">
<html><body><h3 data-section-id="wmrafh" data-start="4" data-end="28"><img fetchpriority="high" decoding="async" class="alignnone size-full wp-image-127269" src="https://www.excellentplc.com/wp-content/uploads/2026/04/1734-PDN-1.jpg" alt="Allen Bradley 1734-PDN Point I/O DeviceNet Interface Module" width="800" height="800"></h3>
<h3 data-section-id="wmrafh" data-start="4" data-end="28">Product Introduction</h3>
<p data-start="29" data-end="386">The Allen Bradley 1734-PDN Point I/O DeviceNet Interface Module is a communication interface module designed to connect POINT I/O systems to a DeviceNet network. Developed by <span class="hover:entity-accent entity-underline inline cursor-pointer align-baseline"><span class="whitespace-normal">Rockwell Automation</span></span>, this module enables seamless data exchange between field I/O devices and higher-level control systems such as PLCs and distributed controllers.</p>
<p data-start="388" data-end="724">In a typical industrial setup, the 1734-PDN acts as the gateway between the POINT I/O rack and the DeviceNet network, handling both data communication and power distribution for connected modules. It supports efficient real-time data transfer and allows multiple I/O modules to operate as a unified node within the network architecture.</p>
<p data-start="726" data-end="982">With its compact structure and DIN rail mounting capability, the module is well suited for space-constrained control panels. It simplifies wiring, reduces installation time, and provides a reliable communication backbone for distributed automation systems.</p>
<hr data-start="984" data-end="987">
<h3 data-section-id="1dqbs77" data-start="988" data-end="1014">Product Specifications</h3>
<div class="TyagGW_tableContainer">
<div class="group TyagGW_tableWrapper flex flex-col-reverse w-fit" tabindex="-1">
<table class="w-fit min-w-(--thread-content-width)" data-start="1015" data-end="1716">
<thead data-start="1015" data-end="1040">
<tr data-start="1015" data-end="1040">
<th class="" data-start="1015" data-end="1031" data-col-size="sm"><strong data-start="1017" data-end="1030">Parameter</strong></th>
<th class="" data-start="1031" data-end="1040" data-col-size="sm">Value</th>
</tr>
</thead>
<tbody data-start="1066" data-end="1716">
<tr data-start="1066" data-end="1108">
<td data-start="1066" data-end="1095" data-col-size="sm"><strong data-start="1068" data-end="1094">Communication Protocol</strong></td>
<td data-start="1095" data-end="1108" data-col-size="sm">DeviceNet</td>
</tr>
<tr data-start="1109" data-end="1139">
<td data-start="1109" data-end="1129" data-col-size="sm"><strong data-start="1111" data-end="1128">Input Voltage</strong></td>
<td data-start="1129" data-end="1139" data-col-size="sm">24 VDC</td>
</tr>
<tr data-start="1140" data-end="1169">
<td data-start="1140" data-end="1160" data-col-size="sm"><strong data-start="1142" data-end="1159">Input Current</strong></td>
<td data-start="1160" data-end="1169" data-col-size="sm">1.3 A</td>
</tr>
<tr data-start="1170" data-end="1212">
<td data-start="1170" data-end="1186" data-col-size="sm"><strong data-start="1172" data-end="1185">Data Rate</strong></td>
<td data-start="1186" data-end="1212" data-col-size="sm">125 / 250 / 500 Kbit/s</td>
</tr>
<tr data-start="1213" data-end="1252">
<td data-start="1213" data-end="1238" data-col-size="sm"><strong data-start="1215" data-end="1237">Maximum I/O Points</strong></td>
<td data-start="1238" data-end="1252" data-col-size="sm">136 Points</td>
</tr>
<tr data-start="1253" data-end="1299">
<td data-start="1253" data-end="1285" data-col-size="sm"><strong data-start="1255" data-end="1284">Maximum Modules Supported</strong></td>
<td data-start="1285" data-end="1299" data-col-size="sm">17 Modules</td>
</tr>
<tr data-start="1300" data-end="1332">
<td data-start="1300" data-end="1320" data-col-size="sm"><strong data-start="1302" data-end="1319">Bus Interface</strong></td>
<td data-start="1320" data-end="1332" data-col-size="sm">POINTBus</td>
</tr>
<tr data-start="1333" data-end="1385">
<td data-start="1333" data-end="1357" data-col-size="sm"><strong data-start="1335" data-end="1356">Power Consumption</strong></td>
<td data-start="1357" data-end="1385" data-col-size="sm">Typical industrial level</td>
</tr>
<tr data-start="1386" data-end="1426">
<td data-start="1386" data-end="1406" data-col-size="sm"><strong data-start="1388" data-end="1405">Mounting Type</strong></td>
<td data-start="1406" data-end="1426" data-col-size="sm">DIN Rail Mounted</td>
</tr>
<tr data-start="1427" data-end="1477">
<td data-start="1427" data-end="1443" data-col-size="sm"><strong data-start="1429" data-end="1442">Isolation</strong></td>
<td data-start="1443" data-end="1477" data-col-size="sm">Electrical isolation supported</td>
</tr>
<tr data-start="1478" data-end="1519">
<td data-start="1478" data-end="1506" data-col-size="sm"><strong data-start="1480" data-end="1505">Operating Temperature</strong></td>
<td data-start="1506" data-end="1519" data-col-size="sm">0 to 55&deg;C</td>
</tr>
<tr data-start="1520" data-end="1561">
<td data-start="1520" data-end="1546" data-col-size="sm"><strong data-start="1522" data-end="1545">Storage Temperature</strong></td>
<td data-start="1546" data-end="1561" data-col-size="sm">-40 to 85&deg;C</td>
</tr>
<tr data-start="1562" data-end="1610">
<td data-start="1562" data-end="1586" data-col-size="sm"><strong data-start="1564" data-end="1585">Relative Humidity</strong></td>
<td data-start="1586" data-end="1610" data-col-size="sm">5&ndash;95% non-condensing</td>
</tr>
<tr data-start="1611" data-end="1647">
<td data-start="1611" data-end="1632" data-col-size="sm"><strong data-start="1613" data-end="1631">Certifications</strong></td>
<td data-start="1632" data-end="1647" data-col-size="sm">CE, UL, CSA</td>
</tr>
<tr data-start="1648" data-end="1691">
<td data-start="1648" data-end="1665" data-col-size="sm"><strong data-start="1650" data-end="1664">Dimensions</strong></td>
<td data-start="1665" data-end="1691" data-col-size="sm">133.4 x 25.4 x 76.2 mm</td>
</tr>
<tr data-start="1692" data-end="1716">
<td data-start="1692" data-end="1705" data-col-size="sm"><strong data-start="1694" data-end="1704">Weight</strong></td>
<td data-start="1705" data-end="1716" data-col-size="sm">0.13 kg</td>
</tr>
</tbody>
</table>
</div>
</div>
<hr data-start="1718" data-end="1721">
<h3 data-section-id="wggvqn" data-start="1722" data-end="1738">Applications</h3>
<p data-start="1740" data-end="1861">&#9679; Used in <strong data-start="1750" data-end="1793">DeviceNet-based distributed I/O systems</strong> for real-time communication between controllers and field devices</p>
<p data-start="1863" data-end="1976">&#9679; Suitable for <strong data-start="1878" data-end="1912">manufacturing automation lines</strong>, including assembly, packaging, and material handling systems</p>
<p data-start="1978" data-end="2096">&#9679; Applied in <strong data-start="1991" data-end="2018">machine control systems</strong> where multiple I/O modules need to be integrated into a single network node</p>
<p data-start="2098" data-end="2202">&#9679; Ideal for <strong data-start="2110" data-end="2142">process control environments</strong> requiring stable and deterministic fieldbus communication</p>
<p data-start="2204" data-end="2317">&#9679; Common in <strong data-start="2216" data-end="2237">retrofit projects</strong>, enabling legacy DeviceNet systems to integrate with modern POINT I/O modules</p>
<p data-start="2319" data-end="2420">&#9679; Used in <strong data-start="2329" data-end="2357">remote I/O installations</strong>, reducing wiring complexity and improving system flexibility</p>
<hr data-start="2422" data-end="2425">
<h3 data-section-id="1l3n95q" data-start="2426" data-end="2440">Advantages</h3>
<p data-start="2442" data-end="2540">&#9679; Provides <strong data-start="2453" data-end="2489">reliable DeviceNet communication</strong>, ensuring stable and deterministic data exchange</p>
<p data-start="2542" data-end="2640">&#9679; Supports up to <strong data-start="2559" data-end="2592">136 I/O points and 17 modules</strong>, enabling flexible and scalable system design</p>
<p data-start="2642" data-end="2745">&#9679; Reduces wiring complexity through <strong data-start="2678" data-end="2708">network-based architecture</strong>, improving installation efficiency</p>
<p data-start="2747" data-end="2869">&#9679; Ensures <strong data-start="2757" data-end="2806">consistent performance at multiple baud rates</strong> (125&ndash;500 Kbit/s), adapting to different network requirements</p>
<p data-start="2871" data-end="2960">&#9679; Compact and <strong data-start="2885" data-end="2907">DIN rail mountable</strong>, making it suitable for tight control panel spaces</p>
<p data-start="2962" data-end="3076">&#9679; Enhances <strong data-start="2973" data-end="3006">system integration capability</strong>, allowing seamless connection between field devices and controllers</p>
</body></html>
<p><a href="https://www.excellentplc.com/allen-bradley-1734-pdn-point-i-o-devicenet-interface-module/">Allen Bradley 1734-PDN Point I/O DeviceNet Interface Module</a>最先出现在<a href="https://www.excellentplc.com">Excellent PLC</a>。</p>
]]></content:encoded>
					
					<wfw:commentRss>https://www.excellentplc.com/allen-bradley-1734-pdn-point-i-o-devicenet-interface-module/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
	</channel>
</rss>
