<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Ethernet/IP ArmorBlock I/O Module - Excellent PLC</title>
	<atom:link href="https://www.excellentplc.com/tag/ethernet-ip-armorblock-i-o-module/feed/" rel="self" type="application/rss+xml" />
	<link>https://www.excellentplc.com/tag/ethernet-ip-armorblock-i-o-module/</link>
	<description></description>
	<lastBuildDate>Wed, 15 Apr 2026 09:30:04 +0000</lastBuildDate>
	<language>zh-Hans</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.9.4</generator>

<image>
	<url>https://www.excellentplc.com/wp-content/uploads/2025/08/cropped-cropped-logo-192x192-1-32x32.jpg</url>
	<title>Ethernet/IP ArmorBlock I/O Module - Excellent PLC</title>
	<link>https://www.excellentplc.com/tag/ethernet-ip-armorblock-i-o-module/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Allen Bradley 1732E-IB16M12 Ethernet/IP ArmorBlock I/O Module</title>
		<link>https://www.excellentplc.com/allen-bradley-1732e-ib16m12-ethernet-ip-armorblock-i-o-module/</link>
					<comments>https://www.excellentplc.com/allen-bradley-1732e-ib16m12-ethernet-ip-armorblock-i-o-module/#respond</comments>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Wed, 15 Apr 2026 09:30:04 +0000</pubDate>
				<category><![CDATA[Allen Bradley]]></category>
		<category><![CDATA[1732E-IB16M12]]></category>
		<category><![CDATA[Allen Bradley 1732E-IB16M12]]></category>
		<category><![CDATA[Ethernet/IP ArmorBlock I/O Module]]></category>
		<guid isPermaLink="false">https://www.excellentplc.com/?p=127206</guid>

					<description><![CDATA[<p>Product Introduction The Allen Bradley 1732E-IB16M12 Et [&#8230;]</p>
<p><a href="https://www.excellentplc.com/allen-bradley-1732e-ib16m12-ethernet-ip-armorblock-i-o-module/">Allen Bradley 1732E-IB16M12 Ethernet/IP ArmorBlock I/O Module</a>最先出现在<a href="https://www.excellentplc.com">Excellent PLC</a>。</p>
]]></description>
										<content:encoded><![CDATA[<!DOCTYPE html PUBLIC "-//W3C//DTD HTML 4.0 Transitional//EN" "http://www.w3.org/TR/REC-html40/loose.dtd">
<html><body><h3 data-section-id="kz71jh" data-start="6" data-end="32"><img fetchpriority="high" decoding="async" class="alignnone size-full wp-image-127213" src="https://www.excellentplc.com/wp-content/uploads/2026/04/1732E-IB16M12-2.jpg" alt="Allen Bradley 1732E-IB16M12 Ethernet/IP ArmorBlock I/O Module" width="800" height="800"></h3>
<h3 data-section-id="kz71jh" data-start="6" data-end="32">Product Introduction</h3>
<p data-start="33" data-end="405">The Allen Bradley 1732E-IB16M12 Ethernet/IP ArmorBlock I/O Module is a rugged, on-machine <strong data-start="123" data-end="147">digital input module</strong> designed for distributed I/O applications in demanding industrial environments. Manufactured by <span class="hover:entity-accent entity-underline inline cursor-pointer align-baseline"><span class="whitespace-normal">Allen-Bradley</span></span>, it is part of the <strong data-start="301" data-end="322">ArmorBlock series</strong>, built to be mounted directly on equipment without the need for a control cabinet.</p>
<p data-start="407" data-end="853">This module provides <strong data-start="428" data-end="457">16 sinking digital inputs</strong> operating at <strong data-start="471" data-end="481">24 VDC</strong>, making it ideal for collecting signals from sensors such as proximity switches, limit switches, and push buttons. With integrated <strong data-start="613" data-end="642">EtherNet/IP communication</strong>, it enables real-time data exchange with PLCs and control systems, reducing wiring complexity and improving system efficiency. Its compact, sealed design ensures reliable performance even in harsh environments.</p>
<hr data-start="855" data-end="860">
<h3 data-section-id="vum7lv" data-start="861" data-end="889">Product Specifications</h3>
<div class="TyagGW_tableContainer">
<div class="group TyagGW_tableWrapper flex flex-col-reverse w-fit" tabindex="-1">
<table class="w-fit min-w-(--thread-content-width)" data-start="891" data-end="1445">
<thead data-start="891" data-end="922">
<tr data-start="891" data-end="922">
<th class="" data-start="891" data-end="907" data-col-size="sm"><strong data-start="893" data-end="906">Parameter</strong></th>
<th class="" data-start="907" data-end="922" data-col-size="sm">Description</th>
</tr>
</thead>
<tbody data-start="953" data-end="1445">
<tr data-start="953" data-end="982">
<td data-start="953" data-end="965" data-col-size="sm"><strong data-start="955" data-end="964">Model</strong></td>
<td data-start="965" data-end="982" data-col-size="sm">1732E-IB16M12</td>
</tr>
<tr data-start="983" data-end="1038">
<td data-start="983" data-end="1002" data-col-size="sm"><strong data-start="985" data-end="1001">Product Type</strong></td>
<td data-start="1002" data-end="1038" data-col-size="sm">Ethernet/IP Digital Input Module</td>
</tr>
<tr data-start="1039" data-end="1083">
<td data-start="1039" data-end="1068" data-col-size="sm"><strong data-start="1041" data-end="1067">Communication Protocol</strong></td>
<td data-start="1068" data-end="1083" data-col-size="sm">EtherNet/IP</td>
</tr>
<tr data-start="1084" data-end="1122">
<td data-start="1084" data-end="1107" data-col-size="sm"><strong data-start="1086" data-end="1106">Number of Inputs</strong></td>
<td data-start="1107" data-end="1122" data-col-size="sm">16 Channels</td>
</tr>
<tr data-start="1123" data-end="1157">
<td data-start="1123" data-end="1140" data-col-size="sm"><strong data-start="1125" data-end="1139">Input Type</strong></td>
<td data-start="1140" data-end="1157" data-col-size="sm">Sinking (NPN)</td>
</tr>
<tr data-start="1158" data-end="1189">
<td data-start="1158" data-end="1178" data-col-size="sm"><strong data-start="1160" data-end="1177">Rated Voltage</strong></td>
<td data-start="1178" data-end="1189" data-col-size="sm">24 V DC</td>
</tr>
<tr data-start="1190" data-end="1230">
<td data-start="1190" data-end="1212" data-col-size="sm"><strong data-start="1192" data-end="1211">Connection Type</strong></td>
<td data-start="1212" data-end="1230" data-col-size="sm">M12 connectors</td>
</tr>
<tr data-start="1231" data-end="1281">
<td data-start="1231" data-end="1251" data-col-size="sm"><strong data-start="1233" data-end="1250">Mounting Type</strong></td>
<td data-start="1251" data-end="1281" data-col-size="sm">On-machine / Screw mounted</td>
</tr>
<tr data-start="1282" data-end="1325">
<td data-start="1282" data-end="1306" data-col-size="sm"><strong data-start="1284" data-end="1305">Application Level</strong></td>
<td data-start="1306" data-end="1325" data-col-size="sm">Distributed I/O</td>
</tr>
<tr data-start="1326" data-end="1379">
<td data-start="1326" data-end="1350" data-col-size="sm"><strong data-start="1328" data-end="1349">Protection Design</strong></td>
<td data-start="1350" data-end="1379" data-col-size="sm">ArmorBlock rugged housing</td>
</tr>
<tr data-start="1380" data-end="1420">
<td data-start="1380" data-end="1397" data-col-size="sm"><strong data-start="1382" data-end="1396">Dimensions</strong></td>
<td data-start="1397" data-end="1420" data-col-size="sm">179 x 65 x 43.25 mm</td>
</tr>
<tr data-start="1421" data-end="1445">
<td data-start="1421" data-end="1434" data-col-size="sm"><strong data-start="1423" data-end="1433">Weight</strong></td>
<td data-start="1434" data-end="1445" data-col-size="sm">0.34 kg</td>
</tr>
</tbody>
</table>
</div>
</div>
<hr data-start="1447" data-end="1452">
<h3 data-section-id="17tovxr" data-start="1453" data-end="1471">Applications</h3>
<p data-start="1473" data-end="1536">&bull; <strong data-start="1475" data-end="1501">On-machine I/O systems</strong> for real-time signal acquisition</p>
<p data-start="1541" data-end="1606">&bull; <strong data-start="1543" data-end="1579">Manufacturing and assembly lines</strong> with distributed control</p>
<p data-start="1611" data-end="1667">&bull; <strong data-start="1613" data-end="1642">Material handling systems</strong> using multiple sensors</p>
<p data-start="1672" data-end="1733">&bull; <strong data-start="1674" data-end="1697">Packaging machinery</strong> requiring reliable digital inputs</p>
<p data-start="1738" data-end="1814">&bull; Harsh environments where <strong data-start="1765" data-end="1802">rugged, cabinet-free installation</strong> is needed</p>
<hr data-start="1816" data-end="1821">
<h3 data-section-id="v8w2hq" data-start="1822" data-end="1838">Advantages</h3>
<p data-start="1840" data-end="1908">&bull; <strong data-start="1842" data-end="1863">16 digital inputs</strong> allow connection of multiple field devices</p>
<p data-start="1913" data-end="1987">&bull; <strong data-start="1915" data-end="1944">EtherNet/IP communication</strong> enables fast and efficient data transfer</p>
<p data-start="1992" data-end="2062">&bull; <strong data-start="1994" data-end="2018">Sinking input design</strong> compatible with common industrial sensors</p>
<p data-start="2067" data-end="2141">&bull; <strong data-start="2069" data-end="2098">Rugged ArmorBlock housing</strong> suitable for harsh industrial conditions</p>
<p data-start="2146" data-end="2213">&bull; <strong data-start="2148" data-end="2171">On-machine mounting</strong> reduces wiring and cabinet requirements</p>
<p data-start="2218" data-end="2288">&bull; <strong data-start="2220" data-end="2238">M12 connectors</strong> provide secure, vibration-resistant connections</p>
</body></html>
<p><a href="https://www.excellentplc.com/allen-bradley-1732e-ib16m12-ethernet-ip-armorblock-i-o-module/">Allen Bradley 1732E-IB16M12 Ethernet/IP ArmorBlock I/O Module</a>最先出现在<a href="https://www.excellentplc.com">Excellent PLC</a>。</p>
]]></content:encoded>
					
					<wfw:commentRss>https://www.excellentplc.com/allen-bradley-1732e-ib16m12-ethernet-ip-armorblock-i-o-module/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Allen Bradley 1732E-IB16 Ethernet/IP ArmorBlock I/O Module</title>
		<link>https://www.excellentplc.com/allen-bradley-1732e-ib16-i-o-module/</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Mon, 05 Jan 2026 06:58:43 +0000</pubDate>
				<category><![CDATA[Allen Bradley]]></category>
		<category><![CDATA[1732E-IB16]]></category>
		<category><![CDATA[Allen Bradley 1732E-IB16]]></category>
		<category><![CDATA[Ethernet/IP ArmorBlock I/O Module]]></category>
		<guid isPermaLink="false">https://www.excellentplc.com/?p=114749</guid>

					<description><![CDATA[<p>Product Introduction The Allen Bradley 1732E-IB16 Ether [&#8230;]</p>
<p><a href="https://www.excellentplc.com/allen-bradley-1732e-ib16-i-o-module/">Allen Bradley 1732E-IB16 Ethernet/IP ArmorBlock I/O Module</a>最先出现在<a href="https://www.excellentplc.com">Excellent PLC</a>。</p>
]]></description>
										<content:encoded><![CDATA[<!DOCTYPE html PUBLIC "-//W3C//DTD HTML 4.0 Transitional//EN" "http://www.w3.org/TR/REC-html40/loose.dtd">
<html><body><h3 data-start="180" data-end="204"><img decoding="async" class="alignnone size-full wp-image-114750" src="https://www.excellentplc.com/wp-content/uploads/2026/01/1732E-IB16-1.jpg" alt="Allen Bradley 1732E-IB16 Ethernet/IP ArmorBlock I/O Module" width="800" height="800"></h3>
<h3 data-start="180" data-end="204">Product Introduction</h3>
<p data-start="206" data-end="518">The <strong data-start="210" data-end="249">Allen Bradley 1732E-IB16 Ethernet/IP ArmorBlock I/O Module</strong>&nbsp;is a distributed <strong data-start="267" data-end="291">digital input module</strong> designed for EtherNet/IP-based industrial automation systems. It provides <strong data-start="366" data-end="399">16 discrete DC input channels</strong>, enabling reliable acquisition of on/off signals from field devices such as sensors, push buttons, and limit switches.</p>
<p data-start="520" data-end="904">As a member of the <strong data-start="539" data-end="564">ARMORBLOCK I/O family</strong>, the 1732E-IB16 is intended for <strong data-start="597" data-end="643">machine-level and field-level installation</strong>, reducing wiring complexity and cabinet space requirements. The sealed housing allows the module to operate reliably in demanding industrial environments, while direct EtherNet/IP communication enables seamless integration with Rockwell Automation controllers.</p>
<hr data-start="906" data-end="909">
<h3 data-start="911" data-end="937">Product Specifications</h3>
<div class="TyagGW_tableContainer">
<div class="group TyagGW_tableWrapper flex w-fit flex-col-reverse" tabindex="-1">
<table class="w-fit min-w-(--thread-content-width)" data-start="939" data-end="1590">
<thead data-start="939" data-end="976">
<tr data-start="939" data-end="976">
<th data-start="939" data-end="955" data-col-size="sm"><strong data-start="941" data-end="954">Parameter</strong></th>
<th data-start="955" data-end="976" data-col-size="sm"><strong data-start="957" data-end="974">Specification</strong></th>
</tr>
</thead>
<tbody data-start="1013" data-end="1590">
<tr data-start="1013" data-end="1053">
<td data-start="1013" data-end="1025" data-col-size="sm"><strong data-start="1015" data-end="1024">Model</strong></td>
<td data-start="1025" data-end="1053" data-col-size="sm">Allen Bradley 1732E-IB16</td>
</tr>
<tr data-start="1054" data-end="1101">
<td data-start="1054" data-end="1073" data-col-size="sm"><strong data-start="1056" data-end="1072">Product Type</strong></td>
<td data-start="1073" data-end="1101" data-col-size="sm">Digital Input I/O Module</td>
</tr>
<tr data-start="1102" data-end="1138">
<td data-start="1102" data-end="1117" data-col-size="sm"><strong data-start="1104" data-end="1116">I/O Type</strong></td>
<td data-start="1117" data-end="1138" data-col-size="sm">Discrete DC Input</td>
</tr>
<tr data-start="1139" data-end="1176">
<td data-start="1139" data-end="1170" data-col-size="sm"><strong data-start="1141" data-end="1169">Number of Digital Inputs</strong></td>
<td data-start="1170" data-end="1176" data-col-size="sm">16</td>
</tr>
<tr data-start="1177" data-end="1208">
<td data-start="1177" data-end="1202" data-col-size="sm"><strong data-start="1179" data-end="1201">Input Voltage Type</strong></td>
<td data-start="1202" data-end="1208" data-col-size="sm">DC</td>
</tr>
<tr data-start="1209" data-end="1245">
<td data-start="1209" data-end="1233" data-col-size="sm"><strong data-start="1211" data-end="1232">Input Signal Type</strong></td>
<td data-start="1233" data-end="1245" data-col-size="sm">Discrete</td>
</tr>
<tr data-start="1246" data-end="1290">
<td data-start="1246" data-end="1275" data-col-size="sm"><strong data-start="1248" data-end="1274">Communication Protocol</strong></td>
<td data-start="1275" data-end="1290" data-col-size="sm">EtherNet/IP</td>
</tr>
<tr data-start="1291" data-end="1338">
<td data-start="1291" data-end="1315" data-col-size="sm"><strong data-start="1293" data-end="1314">Network Interface</strong></td>
<td data-start="1315" data-end="1338" data-col-size="sm">Integrated Ethernet</td>
</tr>
<tr data-start="1339" data-end="1389">
<td data-start="1339" data-end="1360" data-col-size="sm"><strong data-start="1341" data-end="1359">Connector Type</strong></td>
<td data-start="1360" data-end="1389" data-col-size="sm">Industrial I/O connectors</td>
</tr>
<tr data-start="1390" data-end="1425">
<td data-start="1390" data-end="1417" data-col-size="sm"><strong data-start="1392" data-end="1416">Degree of Protection</strong></td>
<td data-start="1417" data-end="1425" data-col-size="sm">IP67</td>
</tr>
<tr data-start="1426" data-end="1481">
<td data-start="1426" data-end="1448" data-col-size="sm"><strong data-start="1428" data-end="1447">Mounting Method</strong></td>
<td data-start="1448" data-end="1481" data-col-size="sm">Machine or structure mounting</td>
</tr>
<tr data-start="1482" data-end="1524">
<td data-start="1482" data-end="1510" data-col-size="sm"><strong data-start="1484" data-end="1509">Operating Environment</strong></td>
<td data-start="1510" data-end="1524" data-col-size="sm">Industrial</td>
</tr>
<tr data-start="1525" data-end="1565">
<td data-start="1525" data-end="1542" data-col-size="sm"><strong data-start="1527" data-end="1541">Dimensions</strong></td>
<td data-start="1542" data-end="1565" data-col-size="sm">179 &times; 65 &times; 43.25 mm</td>
</tr>
<tr data-start="1566" data-end="1590">
<td data-start="1566" data-end="1579" data-col-size="sm"><strong data-start="1568" data-end="1578">Weight</strong></td>
<td data-start="1579" data-end="1590" data-col-size="sm">0.34 kg</td>
</tr>
</tbody>
</table>
</div>
</div>
<hr data-start="1592" data-end="1595">
<h3 data-start="1597" data-end="1613">Applications</h3>
<p data-start="1615" data-end="1732">&bull; <strong data-start="1617" data-end="1644">Distributed I/O Systems</strong><br data-start="1644" data-end="1647">Used for collecting <strong data-start="1669" data-end="1694">digital field signals</strong> in EtherNet/IP automation networks.</p>
<p data-start="1734" data-end="1848">&bull; <strong data-start="1736" data-end="1760">Industrial Machinery</strong><br data-start="1760" data-end="1763">Interfaces with <strong data-start="1781" data-end="1845">limit switches, proximity sensors, and photoelectric sensors</strong>.</p>
<p data-start="1850" data-end="1954">&bull; <strong data-start="1852" data-end="1888">Manufacturing and Assembly Lines</strong><br data-start="1888" data-end="1891">Provides reliable <strong data-start="1911" data-end="1951">machine status and position feedback</strong>.</p>
<p data-start="1956" data-end="2057">&bull; <strong data-start="1958" data-end="1981">Packaging Equipment</strong><br data-start="1981" data-end="1984">Supports fast response for <strong data-start="2013" data-end="2054">discrete control and monitoring tasks</strong>.</p>
<p data-start="2059" data-end="2163">&bull; <strong data-start="2061" data-end="2083">Process Automation</strong><br data-start="2083" data-end="2086">Ensures stable digital input acquisition for <strong data-start="2133" data-end="2160">control logic execution</strong>.</p>
<hr data-start="2165" data-end="2168">
<h3 data-start="2170" data-end="2184">Advantages</h3>
<p data-start="2186" data-end="2307">&bull; <strong data-start="2188" data-end="2227">16-Channel Digital Input Capability</strong><br data-start="2227" data-end="2230">Supports high-density <strong data-start="2254" data-end="2285">discrete signal acquisition</strong> in a single module.</p>
<p data-start="2309" data-end="2422">&bull; <strong data-start="2311" data-end="2338">EtherNet/IP Integration</strong><br data-start="2338" data-end="2341">Enables direct communication with <strong data-start="2377" data-end="2419">Allen Bradley PLCs and control systems</strong>.</p>
<p data-start="2424" data-end="2525">&bull; <strong data-start="2426" data-end="2447">ARMORBLOCK Design</strong><br data-start="2447" data-end="2450">Allows installation <strong data-start="2472" data-end="2498">close to field devices</strong>, reducing wiring length.</p>
<p data-start="2527" data-end="2630">&bull; <strong data-start="2529" data-end="2560">Industrial-Grade Protection</strong><br data-start="2560" data-end="2563">Suitable for use in <strong data-start="2585" data-end="2627">dusty and vibration-prone environments</strong>.</p>
<p data-start="2632" data-end="2742">&bull; <strong data-start="2634" data-end="2668">Simplified System Architecture</strong><br data-start="2668" data-end="2671">Reduces control cabinet complexity and improves system scalability.</p>
</body></html>
<p><a href="https://www.excellentplc.com/allen-bradley-1732e-ib16-i-o-module/">Allen Bradley 1732E-IB16 Ethernet/IP ArmorBlock I/O Module</a>最先出现在<a href="https://www.excellentplc.com">Excellent PLC</a>。</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Allen Bradley 1732E-IB16M12R Ethernet/IP ArmorBlock I/O Module</title>
		<link>https://www.excellentplc.com/allen-bradley-1732e-ib16m12r-i-o-module/</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Mon, 05 Jan 2026 06:47:55 +0000</pubDate>
				<category><![CDATA[Allen Bradley]]></category>
		<category><![CDATA[1732E-IB16M12R]]></category>
		<category><![CDATA[Allen Bradley 1732E-IB16M12R]]></category>
		<category><![CDATA[Ethernet/IP ArmorBlock I/O Module]]></category>
		<guid isPermaLink="false">https://www.excellentplc.com/?p=114743</guid>

					<description><![CDATA[<p>Product Introduction The Allen Bradley 1732E-IB16M12R E [&#8230;]</p>
<p><a href="https://www.excellentplc.com/allen-bradley-1732e-ib16m12r-i-o-module/">Allen Bradley 1732E-IB16M12R Ethernet/IP ArmorBlock I/O Module</a>最先出现在<a href="https://www.excellentplc.com">Excellent PLC</a>。</p>
]]></description>
										<content:encoded><![CDATA[<!DOCTYPE html PUBLIC "-//W3C//DTD HTML 4.0 Transitional//EN" "http://www.w3.org/TR/REC-html40/loose.dtd">
<html><body><h3 data-start="328" data-end="352"><img decoding="async" class="alignnone size-full wp-image-114744" src="https://www.excellentplc.com/wp-content/uploads/2026/01/1732E-IB16M12R-4.jpg" alt="Allen Bradley 1732E-IB16M12R Ethernet/IP ArmorBlock I/O Module" width="800" height="800"></h3>
<h3 data-start="328" data-end="352">Product Introduction</h3>
<p data-start="354" data-end="668">The <strong data-start="358" data-end="401">Allen Bradley 1732E-IB16M12R Ethernet/IP ArmorBlock I/O Module</strong>&nbsp;is a distributed <strong data-start="419" data-end="451">24 V DC digital input module</strong> designed for EtherNet/IP-based industrial automation systems. It provides <strong data-start="526" data-end="568">16 sinking-type digital input channels</strong>, enabling reliable acquisition of field signals from sensors, switches, and other discrete devices.</p>
<p data-start="670" data-end="1073">This module is part of the <strong data-start="697" data-end="722">ARMORBLOCK I/O family</strong> and features a <strong data-start="738" data-end="773">dual-port EtherNet/IP interface</strong> with Device Level Ring (DLR) support for network redundancy. Its sealed housing with <strong data-start="859" data-end="884">IP67/IP69K protection</strong> allows installation directly on machines, even in harsh or washdown environments. The use of <strong data-start="978" data-end="996">M12 connectors</strong> simplifies wiring and enhances reliability in distributed I/O architectures.</p>
<hr data-start="1075" data-end="1078">
<h3 data-start="1080" data-end="1106">Product Specifications</h3>
<div class="TyagGW_tableContainer">
<div class="group TyagGW_tableWrapper flex w-fit flex-col-reverse" tabindex="-1">
<table class="w-fit min-w-(--thread-content-width)" data-start="1108" data-end="1971">
<thead data-start="1108" data-end="1145">
<tr data-start="1108" data-end="1145">
<th data-start="1108" data-end="1124" data-col-size="sm"><strong data-start="1110" data-end="1123">Parameter</strong></th>
<th data-start="1124" data-end="1145" data-col-size="md"><strong data-start="1126" data-end="1143">Specification</strong></th>
</tr>
</thead>
<tbody data-start="1182" data-end="1971">
<tr data-start="1182" data-end="1226">
<td data-start="1182" data-end="1194" data-col-size="sm"><strong data-start="1184" data-end="1193">Model</strong></td>
<td data-start="1194" data-end="1226" data-col-size="md">Allen Bradley 1732E-IB16M12R</td>
</tr>
<tr data-start="1227" data-end="1274">
<td data-start="1227" data-end="1246" data-col-size="sm"><strong data-start="1229" data-end="1245">Product Type</strong></td>
<td data-start="1246" data-end="1274" data-col-size="md">Digital Input I/O Module</td>
</tr>
<tr data-start="1275" data-end="1311">
<td data-start="1275" data-end="1290" data-col-size="sm"><strong data-start="1277" data-end="1289">I/O Type</strong></td>
<td data-start="1290" data-end="1311" data-col-size="md">Discrete DC Input</td>
</tr>
<tr data-start="1312" data-end="1349">
<td data-start="1312" data-end="1343" data-col-size="sm"><strong data-start="1314" data-end="1342">Number of Digital Inputs</strong></td>
<td data-start="1343" data-end="1349" data-col-size="md">16</td>
</tr>
<tr data-start="1350" data-end="1378">
<td data-start="1350" data-end="1367" data-col-size="sm"><strong data-start="1352" data-end="1366">Input Type</strong></td>
<td data-start="1367" data-end="1378" data-col-size="md">Sinking</td>
</tr>
<tr data-start="1379" data-end="1410">
<td data-start="1379" data-end="1404" data-col-size="sm"><strong data-start="1381" data-end="1403">Input Voltage Type</strong></td>
<td data-start="1404" data-end="1410" data-col-size="md">DC</td>
</tr>
<tr data-start="1411" data-end="1463">
<td data-start="1411" data-end="1447" data-col-size="sm"><strong data-start="1413" data-end="1446">Permitted Input Voltage Range</strong></td>
<td data-start="1447" data-end="1463" data-col-size="md">11 &ndash; 30 V DC</td>
</tr>
<tr data-start="1464" data-end="1496">
<td data-start="1464" data-end="1485" data-col-size="sm"><strong data-start="1466" data-end="1484">Supply Voltage</strong></td>
<td data-start="1485" data-end="1496" data-col-size="md">24 V DC</td>
</tr>
<tr data-start="1497" data-end="1541">
<td data-start="1497" data-end="1526" data-col-size="sm"><strong data-start="1499" data-end="1525">Communication Protocol</strong></td>
<td data-start="1526" data-end="1541" data-col-size="md">EtherNet/IP</td>
</tr>
<tr data-start="1542" data-end="1574">
<td data-start="1542" data-end="1567" data-col-size="sm"><strong data-start="1544" data-end="1566">Dual-Port Ethernet</strong></td>
<td data-start="1567" data-end="1574" data-col-size="md">Yes</td>
</tr>
<tr data-start="1575" data-end="1600">
<td data-start="1575" data-end="1593" data-col-size="sm"><strong data-start="1577" data-end="1592">DLR Support</strong></td>
<td data-start="1593" data-end="1600" data-col-size="md">Yes</td>
</tr>
<tr data-start="1601" data-end="1671">
<td data-start="1601" data-end="1622" data-col-size="sm"><strong data-start="1603" data-end="1621">Connector Type</strong></td>
<td data-start="1622" data-end="1671" data-col-size="md">M12 input connectors, M12 Ethernet connectors</td>
</tr>
<tr data-start="1672" data-end="1715">
<td data-start="1672" data-end="1699" data-col-size="sm"><strong data-start="1674" data-end="1698">Degree of Protection</strong></td>
<td data-start="1699" data-end="1715" data-col-size="md">IP67 / IP69K</td>
</tr>
<tr data-start="1716" data-end="1761">
<td data-start="1716" data-end="1744" data-col-size="sm"><strong data-start="1718" data-end="1743">Operating Temperature</strong></td>
<td data-start="1744" data-end="1761" data-col-size="md">-20 to +60 &deg;C</td>
</tr>
<tr data-start="1762" data-end="1805">
<td data-start="1762" data-end="1788" data-col-size="sm"><strong data-start="1764" data-end="1787">Storage Temperature</strong></td>
<td data-start="1788" data-end="1805" data-col-size="md">-40 to +85 &deg;C</td>
</tr>
<tr data-start="1806" data-end="1862">
<td data-start="1806" data-end="1834" data-col-size="sm"><strong data-start="1808" data-end="1833">Max. Ambient Humidity</strong></td>
<td data-start="1834" data-end="1862" data-col-size="md">95 % RH (non-condensing)</td>
</tr>
<tr data-start="1863" data-end="1905">
<td data-start="1863" data-end="1899" data-col-size="sm"><strong data-start="1865" data-end="1898">Suitable for Safety Functions</strong></td>
<td data-start="1899" data-end="1905" data-col-size="md">No</td>
</tr>
<tr data-start="1906" data-end="1946">
<td data-start="1906" data-end="1923" data-col-size="sm"><strong data-start="1908" data-end="1922">Dimensions</strong></td>
<td data-start="1923" data-end="1946" data-col-size="md">179 &times; 65 &times; 43.25 mm</td>
</tr>
<tr data-start="1947" data-end="1971">
<td data-start="1947" data-end="1960" data-col-size="sm"><strong data-start="1949" data-end="1959">Weight</strong></td>
<td data-start="1960" data-end="1971" data-col-size="md">0.34 kg</td>
</tr>
</tbody>
</table>
</div>
</div>
<hr data-start="1973" data-end="1976">
<h3 data-start="1978" data-end="1994">Applications</h3>
<p data-start="1996" data-end="2129">&bull; <strong data-start="1998" data-end="2037">Distributed EtherNet/IP I/O Systems</strong><br data-start="2037" data-end="2040">Used for <strong data-start="2051" data-end="2088">remote digital signal acquisition</strong> in networked automation architectures.</p>
<p data-start="2131" data-end="2268">&bull; <strong data-start="2133" data-end="2157">Industrial Machinery</strong><br data-start="2157" data-end="2160">Connects <strong data-start="2171" data-end="2235">proximity sensors, limit switches, and photoelectric sensors</strong> directly at the machine level.</p>
<p data-start="2270" data-end="2398">&bull; <strong data-start="2272" data-end="2307">Harsh Environment Installations</strong><br data-start="2307" data-end="2310">Suitable for <strong data-start="2325" data-end="2395">washdown areas, outdoor installations, and high-humidity locations</strong>.</p>
<p data-start="2400" data-end="2509">&bull; <strong data-start="2402" data-end="2434">Packaging and Assembly Lines</strong><br data-start="2434" data-end="2437">Supports <strong data-start="2448" data-end="2506">fast and reliable detection of discrete machine states</strong>.</p>
<p data-start="2511" data-end="2627">&bull; <strong data-start="2513" data-end="2535">Process Automation</strong><br data-start="2535" data-end="2538">Provides stable digital input signals for <strong data-start="2582" data-end="2624">monitoring and control logic execution</strong>.</p>
<hr data-start="2629" data-end="2632">
<h3 data-start="2634" data-end="2648">Advantages</h3>
<p data-start="2650" data-end="2768">&bull; <strong data-start="2652" data-end="2688">16-Channel Digital Input Density</strong><br data-start="2688" data-end="2691">Allows <strong data-start="2700" data-end="2729">high signal concentration</strong> in a compact distributed I/O module.</p>
<p data-start="2770" data-end="2881">&bull; <strong data-start="2772" data-end="2806">Dual-Port EtherNet/IP with DLR</strong><br data-start="2806" data-end="2809">Ensures <strong data-start="2819" data-end="2859">network redundancy and fast recovery</strong> in ring topologies.</p>
<p data-start="2883" data-end="2989">&bull; <strong data-start="2885" data-end="2909">M12 Connector Design</strong><br data-start="2909" data-end="2912">Improves <strong data-start="2923" data-end="2973">wiring reliability and installation efficiency</strong> in the field.</p>
<p data-start="2991" data-end="3096">&bull; <strong data-start="2993" data-end="3020">IP67 / IP69K Protection</strong><br data-start="3020" data-end="3023">Enables <strong data-start="3033" data-end="3063">direct-on-machine mounting</strong> without additional enclosures.</p>
<p data-start="3098" data-end="3202">&bull; <strong data-start="3100" data-end="3126">ARMORBLOCK Integration</strong><br data-start="3126" data-end="3129">Seamlessly integrates into <strong data-start="3158" data-end="3199">modular distributed I/O architectures</strong>.</p>
<p data-start="3204" data-end="3330">&bull; <strong data-start="3206" data-end="3238">Industrial-Grade Diagnostics</strong><br data-start="3238" data-end="3241">Supports <strong data-start="3252" data-end="3297">input and communication status monitoring</strong> for efficient troubleshooting.</p>
</body></html>
<p><a href="https://www.excellentplc.com/allen-bradley-1732e-ib16m12r-i-o-module/">Allen Bradley 1732E-IB16M12R Ethernet/IP ArmorBlock I/O Module</a>最先出现在<a href="https://www.excellentplc.com">Excellent PLC</a>。</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Allen Bradley 1732E-8X8M12DR Ethernet/IP ArmorBlock I/O Module</title>
		<link>https://www.excellentplc.com/allen-bradley-1732e-8x8m12dr-i-o-module/</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Mon, 05 Jan 2026 06:22:37 +0000</pubDate>
				<category><![CDATA[Allen Bradley]]></category>
		<category><![CDATA[1732E-8X8M12DR]]></category>
		<category><![CDATA[Allen Bradley 1732E-8X8M12DR]]></category>
		<category><![CDATA[Ethernet/IP ArmorBlock I/O Module]]></category>
		<guid isPermaLink="false">https://www.excellentplc.com/?p=114737</guid>

					<description><![CDATA[<p>Product Introduction The Allen Bradley 1732E-8X8M12DR E [&#8230;]</p>
<p><a href="https://www.excellentplc.com/allen-bradley-1732e-8x8m12dr-i-o-module/">Allen Bradley 1732E-8X8M12DR Ethernet/IP ArmorBlock I/O Module</a>最先出现在<a href="https://www.excellentplc.com">Excellent PLC</a>。</p>
]]></description>
										<content:encoded><![CDATA[<!DOCTYPE html PUBLIC "-//W3C//DTD HTML 4.0 Transitional//EN" "http://www.w3.org/TR/REC-html40/loose.dtd">
<html><body><h3 data-start="168" data-end="192"><img loading="lazy" decoding="async" class="alignnone size-full wp-image-114738" src="https://www.excellentplc.com/wp-content/uploads/2026/01/1732E-8X8M12DR-1.jpg" alt="Allen Bradley 1732E-8X8M12DR Ethernet/IP ArmorBlock I/O Module" width="800" height="800"></h3>
<h3 data-start="168" data-end="192">Product Introduction</h3>
<p data-start="194" data-end="469">The <strong data-start="198" data-end="241">Allen Bradley 1732E-8X8M12DR Ethernet/IP ArmorBlock I/O Module</strong>&nbsp;is a discrete DC I/O block designed for distributed industrial automation systems. It provides <strong data-start="337" data-end="368">8 input and 8 output points</strong> using M12 connectors, enabling reliable connection to sensors, actuators, and other field devices.</p>
<p data-start="471" data-end="829">This ARMORBLOCK module supports <strong data-start="503" data-end="539">Device Level Ring (DLR) Ethernet</strong>, providing high-speed communication and network redundancy for critical applications. Its rugged IP69K-rated design ensures protection against dust, water, and high-pressure washdowns, making it ideal for demanding industrial environments such as food, beverage, and chemical industries.</p>
<hr data-start="831" data-end="834">
<h3 data-start="836" data-end="862">Product Specifications</h3>
<div class="TyagGW_tableContainer">
<div class="group TyagGW_tableWrapper flex w-fit flex-col-reverse" tabindex="-1">
<table class="w-fit min-w-(--thread-content-width)" data-start="864" data-end="1497">
<thead data-start="864" data-end="901">
<tr data-start="864" data-end="901">
<th data-start="864" data-end="880" data-col-size="sm"><strong data-start="866" data-end="879">Parameter</strong></th>
<th data-start="880" data-end="901" data-col-size="md"><strong data-start="882" data-end="899">Specification</strong></th>
</tr>
</thead>
<tbody data-start="938" data-end="1497">
<tr data-start="938" data-end="982">
<td data-start="938" data-end="950" data-col-size="sm"><strong data-start="940" data-end="949">Model</strong></td>
<td data-start="950" data-end="982" data-col-size="md">Allen Bradley 1732E-8X8M12DR</td>
</tr>
<tr data-start="983" data-end="1025">
<td data-start="983" data-end="1002" data-col-size="sm"><strong data-start="985" data-end="1001">Product Type</strong></td>
<td data-start="1002" data-end="1025" data-col-size="md">Discrete I/O Module</td>
</tr>
<tr data-start="1026" data-end="1060">
<td data-start="1026" data-end="1041" data-col-size="sm"><strong data-start="1028" data-end="1040">I/O Type</strong></td>
<td data-start="1041" data-end="1060" data-col-size="md">DC Input/Output</td>
</tr>
<tr data-start="1061" data-end="1085">
<td data-start="1061" data-end="1080" data-col-size="sm"><strong data-start="1063" data-end="1079">Input Points</strong></td>
<td data-start="1080" data-end="1085" data-col-size="md">8</td>
</tr>
<tr data-start="1086" data-end="1111">
<td data-start="1086" data-end="1106" data-col-size="sm"><strong data-start="1088" data-end="1105">Output Points</strong></td>
<td data-start="1106" data-end="1111" data-col-size="md">8</td>
</tr>
<tr data-start="1112" data-end="1178">
<td data-start="1112" data-end="1133" data-col-size="sm"><strong data-start="1114" data-end="1132">Connector Type</strong></td>
<td data-start="1133" data-end="1178" data-col-size="md">M12 I/O connectors, M12 network connector</td>
</tr>
<tr data-start="1179" data-end="1245">
<td data-start="1179" data-end="1208" data-col-size="sm"><strong data-start="1181" data-end="1207">Communication Protocol</strong></td>
<td data-start="1208" data-end="1245" data-col-size="md">Ethernet, Device Level Ring (DLR)</td>
</tr>
<tr data-start="1246" data-end="1299">
<td data-start="1246" data-end="1265" data-col-size="sm"><strong data-start="1248" data-end="1264">Module Style</strong></td>
<td data-start="1265" data-end="1299" data-col-size="md">I/O block, ARMORBLOCK mounting</td>
</tr>
<tr data-start="1300" data-end="1352">
<td data-start="1300" data-end="1318" data-col-size="sm"><strong data-start="1302" data-end="1317">Diagnostics</strong></td>
<td data-start="1318" data-end="1352" data-col-size="md">Module-level status monitoring</td>
</tr>
<tr data-start="1353" data-end="1431">
<td data-start="1353" data-end="1380" data-col-size="sm"><strong data-start="1355" data-end="1379">Environmental Rating</strong></td>
<td data-start="1380" data-end="1431" data-col-size="md">IP69K, suitable for harsh industrial conditions</td>
</tr>
<tr data-start="1432" data-end="1456">
<td data-start="1432" data-end="1445" data-col-size="sm"><strong data-start="1434" data-end="1444">Weight</strong></td>
<td data-start="1445" data-end="1456" data-col-size="md">0.34 kg</td>
</tr>
<tr data-start="1457" data-end="1497">
<td data-start="1457" data-end="1474" data-col-size="sm"><strong data-start="1459" data-end="1473">Dimensions</strong></td>
<td data-start="1474" data-end="1497" data-col-size="md">179 &times; 65 &times; 43.25 mm</td>
</tr>
</tbody>
</table>
</div>
</div>
<hr data-start="1499" data-end="1502">
<h3 data-start="1504" data-end="1520">Applications</h3>
<p data-start="1522" data-end="1630">&bull; <strong data-start="1524" data-end="1555">Distributed Control Systems</strong><br data-start="1555" data-end="1558">Provides <strong data-start="1569" data-end="1594">modular I/O expansion</strong> with 8 input and 8 output points.</p>
<p data-start="1632" data-end="1735">&bull; <strong data-start="1634" data-end="1658">Industrial Machinery</strong><br data-start="1658" data-end="1661">Supports <strong data-start="1672" data-end="1706">signal acquisition and control</strong> for sensors and actuators.</p>
<p data-start="1737" data-end="1856">&bull; <strong data-start="1739" data-end="1770">Ethernet Network Automation</strong><br data-start="1770" data-end="1773">Enables <strong data-start="1783" data-end="1824">Device Level Ring (DLR) communication</strong>, ensuring network redundancy.</p>
<p data-start="1858" data-end="1989">&bull; <strong data-start="1860" data-end="1903">Food, Beverage, and Chemical Industries</strong><br data-start="1903" data-end="1906">IP69K protection allows <strong data-start="1932" data-end="1986">safe operation under washdown and harsh conditions</strong>.</p>
<p data-start="1991" data-end="2121">&bull; <strong data-start="1993" data-end="2023">ARMORBLOCK Modular Systems</strong><br data-start="2023" data-end="2026">Integrates seamlessly into <strong data-start="2055" data-end="2088">distributed I/O architectures</strong> for scalable system expansion.</p>
<hr data-start="2123" data-end="2126">
<h3 data-start="2128" data-end="2142">Advantages</h3>
<p data-start="2144" data-end="2231">&bull; <strong data-start="2146" data-end="2165">Dual I/O Points</strong><br data-start="2165" data-end="2168">Combines 8 inputs and 8 outputs in a single compact module.</p>
<p data-start="2233" data-end="2329">&bull; <strong data-start="2235" data-end="2265">Device Level Ring Ethernet</strong><br data-start="2265" data-end="2268">Provides <strong data-start="2279" data-end="2326">high-speed, redundant network communication</strong>.</p>
<p data-start="2331" data-end="2433">&bull; <strong data-start="2333" data-end="2359">IP69K-Rated Protection</strong><br data-start="2359" data-end="2362">Ensures <strong data-start="2372" data-end="2409">reliability in harsh environments</strong>, including washdowns.</p>
<p data-start="2435" data-end="2530">&bull; <strong data-start="2437" data-end="2460">Diagnostics Support</strong><br data-start="2460" data-end="2463">Module-level <strong data-start="2478" data-end="2499">status monitoring</strong> helps detect faults quickly.</p>
<p data-start="2532" data-end="2631">&bull; <strong data-start="2534" data-end="2564">Compact and Modular Design</strong><br data-start="2564" data-end="2567">Fits ARMORBLOCK systems for <strong data-start="2597" data-end="2628">efficient panel space usage</strong>.</p>
<p data-start="2633" data-end="2739">&bull; <strong data-start="2635" data-end="2662">Rugged Industrial Build</strong><br data-start="2662" data-end="2665">Designed to withstand <strong data-start="2689" data-end="2736">dust, vibration, and high-pressure cleaning</strong>.</p>
</body></html>
<p><a href="https://www.excellentplc.com/allen-bradley-1732e-8x8m12dr-i-o-module/">Allen Bradley 1732E-8X8M12DR Ethernet/IP ArmorBlock I/O Module</a>最先出现在<a href="https://www.excellentplc.com">Excellent PLC</a>。</p>
]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>
