<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Modbus Master/Slave Enhanced Communication Module - Excellent PLC</title>
	<atom:link href="https://www.excellentplc.com/tag/modbus-master-slave-enhanced-communication-module/feed/" rel="self" type="application/rss+xml" />
	<link>https://www.excellentplc.com/tag/modbus-master-slave-enhanced-communication-module/</link>
	<description></description>
	<lastBuildDate>Wed, 08 Apr 2026 06:24:06 +0000</lastBuildDate>
	<language>zh-Hans</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.9.4</generator>

<image>
	<url>https://www.excellentplc.com/wp-content/uploads/2025/08/cropped-cropped-logo-192x192-1-32x32.jpg</url>
	<title>Modbus Master/Slave Enhanced Communication Module - Excellent PLC</title>
	<link>https://www.excellentplc.com/tag/modbus-master-slave-enhanced-communication-module/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>ProSoft MVI56E-MCMXT Modbus Master/Slave Enhanced Communication Module</title>
		<link>https://www.excellentplc.com/prosoft-mvi56e-mcmxt-modbus-master-slave-enhanced-communication-module/</link>
					<comments>https://www.excellentplc.com/prosoft-mvi56e-mcmxt-modbus-master-slave-enhanced-communication-module/#respond</comments>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Wed, 08 Apr 2026 06:24:06 +0000</pubDate>
				<category><![CDATA[Allen Bradley]]></category>
		<category><![CDATA[Modbus Master/Slave Enhanced Communication Module]]></category>
		<category><![CDATA[MVI56E-MCMXT]]></category>
		<category><![CDATA[ProSoft]]></category>
		<category><![CDATA[ProSoft MVI56E-MCMXT]]></category>
		<guid isPermaLink="false">https://www.excellentplc.com/?p=126537</guid>

					<description><![CDATA[<p>Product Introduction The ProSoft MVI56E-MCMXT is an enh [&#8230;]</p>
<p><a href="https://www.excellentplc.com/prosoft-mvi56e-mcmxt-modbus-master-slave-enhanced-communication-module/">ProSoft MVI56E-MCMXT Modbus Master/Slave Enhanced Communication Module</a>最先出现在<a href="https://www.excellentplc.com">Excellent PLC</a>。</p>
]]></description>
										<content:encoded><![CDATA[<!DOCTYPE html PUBLIC "-//W3C//DTD HTML 4.0 Transitional//EN" "http://www.w3.org/TR/REC-html40/loose.dtd">
<html><body><h3 data-section-id="fp1bwt" data-start="6" data-end="36"><img fetchpriority="high" decoding="async" class="alignnone size-full wp-image-126538" src="https://www.excellentplc.com/wp-content/uploads/2026/04/MVI56E-MCMXT-1.jpg" alt="ProSoft MVI56E-MCMXT Modbus Master/Slave Enhanced Communication Module" width="800" height="800"></h3>
<h3 data-section-id="fp1bwt" data-start="6" data-end="36"><span role="text"><strong data-start="10" data-end="34">Product Introduction</strong></span></h3>
<p data-start="38" data-end="445">The ProSoft MVI56E-MCMXT is an enhanced Modbus Master/Slave communication module specifically developed for Allen-Bradley ControlLogix processors, with extended environmental capabilities for harsh industrial conditions. As part of the Logix-XT&trade; platform, this module is engineered to operate reliably in extreme temperatures and demanding environments where standard modules may not perform consistently.</p>
<p data-start="447" data-end="775">This module functions as a bridge between the ControlLogix backplane and Modbus-compatible devices, supporting both Master and Slave communication modes. It allows the controller to actively poll field devices while also responding to incoming requests, making it suitable for complex and distributed automation architectures.</p>
<p data-start="777" data-end="1125">Equipped with dual Modbus communication ports and a dedicated configuration port, the MVI56E-MCMXT provides flexible connectivity and simplified setup. Its conformal coating enhances resistance to moisture, dust, and corrosive atmospheres, ensuring long-term reliability in industries such as oil &amp; gas, power generation, and heavy manufacturing.</p>
<hr data-start="1128" data-end="1133">
<h3 data-section-id="10kfchv" data-start="1134" data-end="1166"><span role="text"><strong data-start="1138" data-end="1164">Product Specifications</strong></span></h3>
<div class="TyagGW_tableContainer">
<div class="group TyagGW_tableWrapper flex flex-col-reverse w-fit" tabindex="-1">
<table class="w-fit min-w-(--thread-content-width)" data-start="1168" data-end="1990">
<thead data-start="1168" data-end="1193">
<tr data-start="1168" data-end="1193">
<th class="" data-start="1168" data-end="1184" data-col-size="sm"><strong data-start="1170" data-end="1183">Parameter</strong></th>
<th class="" data-start="1184" data-end="1193" data-col-size="md">Value</th>
</tr>
</thead>
<tbody data-start="1217" data-end="1990">
<tr data-start="1217" data-end="1253">
<td data-start="1217" data-end="1237" data-col-size="sm"><strong data-start="1219" data-end="1236">Product Model</strong></td>
<td data-start="1237" data-end="1253" data-col-size="md">MVI56E-MCMXT</td>
</tr>
<tr data-start="1254" data-end="1295">
<td data-start="1254" data-end="1273" data-col-size="sm"><strong data-start="1256" data-end="1272">Manufacturer</strong></td>
<td data-start="1273" data-end="1295" data-col-size="md">ProSoft Technology</td>
</tr>
<tr data-start="1296" data-end="1367">
<td data-start="1296" data-end="1314" data-col-size="sm"><strong data-start="1298" data-end="1313">Module Type</strong></td>
<td data-start="1314" data-end="1367" data-col-size="md">Modbus Master/Slave Enhanced Communication Module</td>
</tr>
<tr data-start="1368" data-end="1438">
<td data-start="1368" data-end="1397" data-col-size="sm"><strong data-start="1370" data-end="1396">Platform Compatibility</strong></td>
<td data-start="1397" data-end="1438" data-col-size="md">Allen-Bradley ControlLogix (Logix-XT)</td>
</tr>
<tr data-start="1439" data-end="1482">
<td data-start="1439" data-end="1459" data-col-size="sm"><strong data-start="1441" data-end="1458">Functionality</strong></td>
<td data-start="1459" data-end="1482" data-col-size="md">Modbus Master/Slave</td>
</tr>
<tr data-start="1483" data-end="1538">
<td data-start="1483" data-end="1508" data-col-size="sm"><strong data-start="1485" data-end="1507">Configuration Port</strong></td>
<td data-start="1508" data-end="1538" data-col-size="md">1 &times; RJ45 Serial Port (CFG)</td>
</tr>
<tr data-start="1539" data-end="1590">
<td data-start="1539" data-end="1565" data-col-size="sm"><strong data-start="1541" data-end="1564">Communication Ports</strong></td>
<td data-start="1565" data-end="1590" data-col-size="md">2 &times; RJ45 Modbus Ports</td>
</tr>
<tr data-start="1591" data-end="1642">
<td data-start="1591" data-end="1620" data-col-size="sm"><strong data-start="1593" data-end="1619">Communication Protocol</strong></td>
<td data-start="1620" data-end="1642" data-col-size="md">Modbus RTU / ASCII</td>
</tr>
<tr data-start="1643" data-end="1692">
<td data-start="1643" data-end="1672" data-col-size="sm"><strong data-start="1645" data-end="1671">Backplane Current Load</strong></td>
<td data-start="1672" data-end="1692" data-col-size="md">800 mA @ 5.1 VDC</td>
</tr>
<tr data-start="1693" data-end="1728">
<td data-start="1693" data-end="1718" data-col-size="sm"><strong data-start="1695" data-end="1717">Power Requirements</strong></td>
<td data-start="1718" data-end="1728" data-col-size="md">24 VDC</td>
</tr>
<tr data-start="1729" data-end="1771">
<td data-start="1729" data-end="1746" data-col-size="sm"><strong data-start="1731" data-end="1745">Indicators</strong></td>
<td data-start="1746" data-end="1771" data-col-size="md">LED Status Indicators</td>
</tr>
<tr data-start="1772" data-end="1816">
<td data-start="1772" data-end="1800" data-col-size="sm"><strong data-start="1774" data-end="1799">Operating Temperature</strong></td>
<td data-start="1800" data-end="1816" data-col-size="md">-40 to +85&deg;C</td>
</tr>
<tr data-start="1817" data-end="1869">
<td data-start="1817" data-end="1848" data-col-size="sm"><strong data-start="1819" data-end="1847">Environmental Protection</strong></td>
<td data-start="1848" data-end="1869" data-col-size="md">Conformal Coating</td>
</tr>
<tr data-start="1870" data-end="1920">
<td data-start="1870" data-end="1885" data-col-size="sm"><strong data-start="1872" data-end="1884">Mounting</strong></td>
<td data-start="1885" data-end="1920" data-col-size="md">ControlLogix Rack (Single Slot)</td>
</tr>
<tr data-start="1921" data-end="1965">
<td data-start="1921" data-end="1938" data-col-size="sm"><strong data-start="1923" data-end="1937">Dimensions</strong></td>
<td data-start="1938" data-end="1965" data-col-size="md">145.2 &times; 34.6 &times; 139.6 mm</td>
</tr>
<tr data-start="1966" data-end="1990">
<td data-start="1966" data-end="1979" data-col-size="sm"><strong data-start="1968" data-end="1978">Weight</strong></td>
<td data-start="1979" data-end="1990" data-col-size="md">0.45 kg</td>
</tr>
</tbody>
</table>
</div>
</div>
<hr data-start="1993" data-end="1998">
<h3 data-section-id="xdxar3" data-start="1999" data-end="2021"><span role="text"><strong data-start="2003" data-end="2019">Applications</strong></span></h3>
<p data-start="2023" data-end="2165">&#9679; <strong data-start="2025" data-end="2065">Harsh environment automation systems</strong>, such as oil &amp; gas fields and offshore platforms where extended temperature tolerance is required</p>
<p data-start="2167" data-end="2297">&#9679; <strong data-start="2169" data-end="2203">Power generation and utilities</strong>, enabling reliable Modbus communication between ControlLogix PLCs and field instrumentation</p>
<p data-start="2299" data-end="2407">&#9679; <strong data-start="2301" data-end="2323">Process industries</strong>, including chemical and petrochemical plants with corrosive or humid environments</p>
<p data-start="2409" data-end="2527">&#9679; <strong data-start="2411" data-end="2442">Distributed control systems</strong>, supporting simultaneous Master/Slave communication across multiple Modbus devices</p>
<p data-start="2529" data-end="2632">&#9679; <strong data-start="2531" data-end="2562">System integration projects</strong>, bridging legacy Modbus networks with modern ControlLogix platforms</p>
<p data-start="2634" data-end="2751">&#9679; <strong data-start="2636" data-end="2675">Remote monitoring and SCADA systems</strong>, ensuring stable data transmission under extreme environmental conditions</p>
<hr data-start="2754" data-end="2759">
<h3 data-section-id="1cmhqn2" data-start="2760" data-end="2780"><span role="text"><strong data-start="2764" data-end="2778">Advantages</strong></span></h3>
<p data-start="2782" data-end="2895">&#9679; <strong data-start="2784" data-end="2829">Extended temperature range (-40 to +85&deg;C)</strong>, ensuring stable performance in extreme industrial environments</p>
<p data-start="2897" data-end="2994">&#9679; <strong data-start="2899" data-end="2931">Conformal coating protection</strong>, improving resistance to moisture, dust, and corrosive gases</p>
<p data-start="2996" data-end="3103">&#9679; <strong data-start="2998" data-end="3030">Dual Master/Slave capability</strong>, allowing flexible and efficient communication within complex networks</p>
<p data-start="3105" data-end="3190">&#9679; <strong data-start="3107" data-end="3144">Seamless ControlLogix integration</strong>, eliminating the need for external gateways</p>
<p data-start="3192" data-end="3279">&#9679; <strong data-start="3194" data-end="3226">Multiple communication ports</strong>, supporting flexible Modbus network configurations</p>
<p data-start="3281" data-end="3389">&#9679; <strong data-start="3283" data-end="3307">Enhanced reliability</strong>, specifically designed for the Logix-XT platform and harsh operating conditions</p>
</body></html>
<p><a href="https://www.excellentplc.com/prosoft-mvi56e-mcmxt-modbus-master-slave-enhanced-communication-module/">ProSoft MVI56E-MCMXT Modbus Master/Slave Enhanced Communication Module</a>最先出现在<a href="https://www.excellentplc.com">Excellent PLC</a>。</p>
]]></content:encoded>
					
					<wfw:commentRss>https://www.excellentplc.com/prosoft-mvi56e-mcmxt-modbus-master-slave-enhanced-communication-module/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>ProSoft MVI56E-MCM Modbus Master/Slave Enhanced Communication Module</title>
		<link>https://www.excellentplc.com/prosoft-mvi56e-mcm-modbus-master-slave-enhanced-communication-module/</link>
					<comments>https://www.excellentplc.com/prosoft-mvi56e-mcm-modbus-master-slave-enhanced-communication-module/#respond</comments>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Wed, 08 Apr 2026 02:33:40 +0000</pubDate>
				<category><![CDATA[Allen Bradley]]></category>
		<category><![CDATA[Modbus Master/Slave Enhanced Communication Module]]></category>
		<category><![CDATA[MVI56E-MCM]]></category>
		<category><![CDATA[ProSoft]]></category>
		<category><![CDATA[ProSoft MVI56E-MCM]]></category>
		<guid isPermaLink="false">https://www.excellentplc.com/?p=126502</guid>

					<description><![CDATA[<p>Product Introduction The ProSoft MVI56E-MCM is an enhan [&#8230;]</p>
<p><a href="https://www.excellentplc.com/prosoft-mvi56e-mcm-modbus-master-slave-enhanced-communication-module/">ProSoft MVI56E-MCM Modbus Master/Slave Enhanced Communication Module</a>最先出现在<a href="https://www.excellentplc.com">Excellent PLC</a>。</p>
]]></description>
										<content:encoded><![CDATA[<!DOCTYPE html PUBLIC "-//W3C//DTD HTML 4.0 Transitional//EN" "http://www.w3.org/TR/REC-html40/loose.dtd">
<html><body><h3 data-section-id="fp1bwt" data-start="6" data-end="36"><img decoding="async" class="alignnone size-full wp-image-126503" src="https://www.excellentplc.com/wp-content/uploads/2026/04/MVI56E-MCM-1.jpg" alt="ProSoft MVI56E-MCM Modbus Master/Slave Enhanced Communication Module" width="800" height="800"></h3>
<h3 data-section-id="fp1bwt" data-start="6" data-end="36"><span role="text"><strong data-start="10" data-end="34">Product Introduction</strong></span></h3>
<p data-start="38" data-end="393">The ProSoft MVI56E-MCM is an enhanced Modbus Master/Slave communication module designed for direct integration with Allen-Bradley ControlLogix processors. It functions as a dedicated interface between the ControlLogix backplane and external Modbus networks, allowing seamless and reliable data exchange without requiring additional communication gateways.</p>
<p data-start="395" data-end="721">Installed as a standard I/O module within the ControlLogix rack, the MVI56E-MCM enables the PLC to communicate directly with Modbus-compatible devices such as meters, drives, remote I/O systems, and instrumentation. This simplifies system design and significantly reduces integration complexity in mixed-protocol environments.</p>
<p data-start="723" data-end="996">The module supports both Master and Slave modes, making it highly flexible in various control architectures. It can actively poll field devices while simultaneously responding to requests from higher-level systems, ensuring smooth data flow across different network layers.</p>
<p data-start="998" data-end="1316">Equipped with a dedicated configuration port and dual communication ports, the module offers convenient setup, diagnostics, and maintenance. Its enhanced processing capability ensures stable performance even in applications with high communication loads, making it suitable for demanding industrial automation systems.</p>
<hr data-start="1319" data-end="1324">
<h3 data-section-id="10kfchv" data-start="1325" data-end="1357"><span role="text"><strong data-start="1329" data-end="1355">Product Specifications</strong></span></h3>
<div class="TyagGW_tableContainer">
<div class="group TyagGW_tableWrapper flex flex-col-reverse w-fit" tabindex="-1">
<table class="w-fit min-w-(--thread-content-width)" data-start="1359" data-end="2050">
<thead data-start="1359" data-end="1384">
<tr data-start="1359" data-end="1384">
<th class="" data-start="1359" data-end="1375" data-col-size="sm"><strong data-start="1361" data-end="1374">Parameter</strong></th>
<th class="" data-start="1375" data-end="1384" data-col-size="sm">Value</th>
</tr>
</thead>
<tbody data-start="1408" data-end="2050">
<tr data-start="1408" data-end="1442">
<td data-start="1408" data-end="1428" data-col-size="sm"><strong data-start="1410" data-end="1427">Product Model</strong></td>
<td data-start="1428" data-end="1442" data-col-size="sm">MVI56E-MCM</td>
</tr>
<tr data-start="1443" data-end="1484">
<td data-start="1443" data-end="1462" data-col-size="sm"><strong data-start="1445" data-end="1461">Manufacturer</strong></td>
<td data-start="1462" data-end="1484" data-col-size="sm">ProSoft Technology</td>
</tr>
<tr data-start="1485" data-end="1534">
<td data-start="1485" data-end="1503" data-col-size="sm"><strong data-start="1487" data-end="1502">Module Type</strong></td>
<td data-start="1503" data-end="1534" data-col-size="sm">Modbus Communication Module</td>
</tr>
<tr data-start="1535" data-end="1578">
<td data-start="1535" data-end="1555" data-col-size="sm"><strong data-start="1537" data-end="1554">Functionality</strong></td>
<td data-start="1555" data-end="1578" data-col-size="sm">Modbus Master/Slave</td>
</tr>
<tr data-start="1579" data-end="1638">
<td data-start="1579" data-end="1608" data-col-size="sm"><strong data-start="1581" data-end="1607">Platform Compatibility</strong></td>
<td data-start="1608" data-end="1638" data-col-size="sm">Allen-Bradley ControlLogix</td>
</tr>
<tr data-start="1639" data-end="1682">
<td data-start="1639" data-end="1664" data-col-size="sm"><strong data-start="1641" data-end="1663">Configuration Port</strong></td>
<td data-start="1664" data-end="1682" data-col-size="sm">1 &times; RJ45 (CFG)</td>
</tr>
<tr data-start="1683" data-end="1730">
<td data-start="1683" data-end="1709" data-col-size="sm"><strong data-start="1685" data-end="1708">Communication Ports</strong></td>
<td data-start="1709" data-end="1730" data-col-size="sm">2 &times; RJ45 (Modbus)</td>
</tr>
<tr data-start="1731" data-end="1785">
<td data-start="1731" data-end="1767" data-col-size="sm"><strong data-start="1733" data-end="1766">Power Consumption (Backplane)</strong></td>
<td data-start="1767" data-end="1785" data-col-size="sm">5 VDC @ 800 mA</td>
</tr>
<tr data-start="1786" data-end="1839">
<td data-start="1786" data-end="1822" data-col-size="sm"><strong data-start="1788" data-end="1821">Power Consumption (Backplane)</strong></td>
<td data-start="1822" data-end="1839" data-col-size="sm">24 VDC @ 3 mA</td>
</tr>
<tr data-start="1840" data-end="1883">
<td data-start="1840" data-end="1868" data-col-size="sm"><strong data-start="1842" data-end="1867">Operating Temperature</strong></td>
<td data-start="1868" data-end="1883" data-col-size="sm">0 to +60 &deg;C</td>
</tr>
<tr data-start="1884" data-end="1925">
<td data-start="1884" data-end="1904" data-col-size="sm"><strong data-start="1886" data-end="1903">Mounting Type</strong></td>
<td data-start="1904" data-end="1925" data-col-size="sm">ControlLogix Rack</td>
</tr>
<tr data-start="1926" data-end="1980">
<td data-start="1926" data-end="1953" data-col-size="sm"><strong data-start="1928" data-end="1952">Data Exchange Method</strong></td>
<td data-start="1953" data-end="1980" data-col-size="sm">Backplane I/O Interface</td>
</tr>
<tr data-start="1981" data-end="2025">
<td data-start="1981" data-end="1998" data-col-size="sm"><strong data-start="1983" data-end="1997">Dimensions</strong></td>
<td data-start="1998" data-end="2025" data-col-size="sm">145.2 &times; 34.6 &times; 139.6 mm</td>
</tr>
<tr data-start="2026" data-end="2050">
<td data-start="2026" data-end="2039" data-col-size="sm"><strong data-start="2028" data-end="2038">Weight</strong></td>
<td data-start="2039" data-end="2050" data-col-size="sm">0.45 kg</td>
</tr>
</tbody>
</table>
</div>
</div>
<hr data-start="2053" data-end="2058">
<h3 data-section-id="xdxar3" data-start="2059" data-end="2081"><span role="text"><strong data-start="2063" data-end="2079">Applications</strong></span></h3>
<p data-start="2083" data-end="2196">&#9679; <strong data-start="2085" data-end="2131">ControlLogix to Modbus network integration</strong>, enabling seamless communication with Modbus RTU/ASCII devices</p>
<p data-start="2198" data-end="2312">&#9679; <strong data-start="2200" data-end="2233">Industrial automation systems</strong>, where multiple communication protocols must coexist within one architecture</p>
<p data-start="2314" data-end="2418">&#9679; <strong data-start="2316" data-end="2348">SCADA and monitoring systems</strong>, ensuring stable and continuous data acquisition from field devices</p>
<p data-start="2420" data-end="2532">&#9679; <strong data-start="2422" data-end="2459">Energy and utilities applications</strong>, integrating power meters, protection relays, and monitoring equipment</p>
<p data-start="2534" data-end="2653">&#9679; <strong data-start="2536" data-end="2558">Process industries</strong>, including oil &amp; gas, chemical, and water treatment systems requiring reliable communication</p>
<p data-start="2655" data-end="2757">&#9679; <strong data-start="2657" data-end="2690">System upgrades and retrofits</strong>, connecting modern PLC platforms to legacy Modbus infrastructure</p>
<hr data-start="2760" data-end="2765">
<h3 data-section-id="1cmhqn2" data-start="2766" data-end="2786"><span role="text"><strong data-start="2770" data-end="2784">Advantages</strong></span></h3>
<p data-start="2788" data-end="2886">&#9679; <strong data-start="2790" data-end="2822">Dual Master/Slave capability</strong>, allowing flexible communication roles within the same module</p>
<p data-start="2888" data-end="3009">&#9679; <strong data-start="2890" data-end="2922">Direct backplane integration</strong>, eliminating the need for external protocol converters and simplifying system design</p>
<p data-start="3011" data-end="3128">&#9679; <strong data-start="3013" data-end="3051">Enhanced communication performance</strong>, supporting efficient and stable data transfer under heavy load conditions</p>
<p data-start="3130" data-end="3227">&#9679; <strong data-start="3132" data-end="3164">Multiple communication ports</strong>, enabling simultaneous connection to multiple Modbus devices</p>
<p data-start="3229" data-end="3333">&#9679; <strong data-start="3231" data-end="3262">User-friendly configuration</strong>, with a dedicated configuration port for quick setup and diagnostics</p>
<p data-start="3335" data-end="3435">&#9679; <strong data-start="3337" data-end="3384">High reliability in industrial environments</strong>, ensuring consistent operation over long periods</p>
</body></html>
<p><a href="https://www.excellentplc.com/prosoft-mvi56e-mcm-modbus-master-slave-enhanced-communication-module/">ProSoft MVI56E-MCM Modbus Master/Slave Enhanced Communication Module</a>最先出现在<a href="https://www.excellentplc.com">Excellent PLC</a>。</p>
]]></content:encoded>
					
					<wfw:commentRss>https://www.excellentplc.com/prosoft-mvi56e-mcm-modbus-master-slave-enhanced-communication-module/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
	</channel>
</rss>
