<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>MVI56-HART - Excellent PLC</title>
	<atom:link href="https://www.excellentplc.com/tag/mvi56-hart/feed/" rel="self" type="application/rss+xml" />
	<link>https://www.excellentplc.com/tag/mvi56-hart/</link>
	<description></description>
	<lastBuildDate>Wed, 08 Apr 2026 06:43:11 +0000</lastBuildDate>
	<language>zh-Hans</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.9.4</generator>

<image>
	<url>https://www.excellentplc.com/wp-content/uploads/2025/08/cropped-cropped-logo-192x192-1-32x32.jpg</url>
	<title>MVI56-HART - Excellent PLC</title>
	<link>https://www.excellentplc.com/tag/mvi56-hart/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>ProSoft MVI56-HART Multi-drop Master Communication Module</title>
		<link>https://www.excellentplc.com/prosoft-mvi56-hart-multi-drop-master-communication-module/</link>
					<comments>https://www.excellentplc.com/prosoft-mvi56-hart-multi-drop-master-communication-module/#respond</comments>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Wed, 08 Apr 2026 06:43:11 +0000</pubDate>
				<category><![CDATA[Allen Bradley]]></category>
		<category><![CDATA[Multi-drop Master Communication Module]]></category>
		<category><![CDATA[MVI56-HART]]></category>
		<category><![CDATA[ProSoft]]></category>
		<category><![CDATA[ProSoft MVI56-HART]]></category>
		<guid isPermaLink="false">https://www.excellentplc.com/?p=126543</guid>

					<description><![CDATA[<p>Product Introduction The ProSoft MVI56-HART is a multi- [&#8230;]</p>
<p><a href="https://www.excellentplc.com/prosoft-mvi56-hart-multi-drop-master-communication-module/">ProSoft MVI56-HART Multi-drop Master Communication Module</a>最先出现在<a href="https://www.excellentplc.com">Excellent PLC</a>。</p>
]]></description>
										<content:encoded><![CDATA[<!DOCTYPE html PUBLIC "-//W3C//DTD HTML 4.0 Transitional//EN" "http://www.w3.org/TR/REC-html40/loose.dtd">
<html><body><h3 data-section-id="fp1bwt" data-start="6" data-end="36"><img fetchpriority="high" decoding="async" class="alignnone size-full wp-image-126545" src="https://www.excellentplc.com/wp-content/uploads/2026/04/MVI56-HART-1-1.jpg" alt="ProSoft MVI56-HART Multi-drop Master Communication Module" width="800" height="800"></h3>
<h3 data-section-id="fp1bwt" data-start="6" data-end="36"><span role="text"><strong data-start="10" data-end="34">Product Introduction</strong></span></h3>
<p data-start="38" data-end="366">The ProSoft MVI56-HART is a multi-drop Master communication module designed for seamless integration with Allen-Bradley ControlLogix processors. It provides a reliable interface between the ControlLogix backplane and HART-enabled field devices, enabling efficient communication with smart transmitters, sensors, and actuators.</p>
<p data-start="368" data-end="708">This module supports four independent HART communication channels, allowing multiple field devices to be connected in a multi-drop configuration. It acts as a Master on the HART network, collecting diagnostic, configuration, and process data from connected slave devices and transferring it directly to the PLC for control and monitoring.</p>
<p data-start="710" data-end="1025">Built for industrial environments, the MVI56-HART offers robust performance with high resistance to vibration, shock, and varying environmental conditions. It is widely used in process industries where HART communication is essential for accessing advanced device diagnostics and improving operational visibility.</p>
<hr data-start="1028" data-end="1033">
<h3 data-section-id="10kfchv" data-start="1034" data-end="1066"><span role="text"><strong data-start="1038" data-end="1064">Product Specifications</strong></span></h3>
<div class="TyagGW_tableContainer">
<div class="group TyagGW_tableWrapper flex flex-col-reverse w-fit" tabindex="-1">
<table class="w-fit min-w-(--thread-content-width)" data-start="1068" data-end="1876">
<thead data-start="1068" data-end="1093">
<tr data-start="1068" data-end="1093">
<th class="" data-start="1068" data-end="1084" data-col-size="sm"><strong data-start="1070" data-end="1083">Parameter</strong></th>
<th class="" data-start="1084" data-end="1093" data-col-size="md">Value</th>
</tr>
</thead>
<tbody data-start="1117" data-end="1876">
<tr data-start="1117" data-end="1151">
<td data-start="1117" data-end="1137" data-col-size="sm"><strong data-start="1119" data-end="1136">Product Model</strong></td>
<td data-start="1137" data-end="1151" data-col-size="md">MVI56-HART</td>
</tr>
<tr data-start="1152" data-end="1193">
<td data-start="1152" data-end="1171" data-col-size="sm"><strong data-start="1154" data-end="1170">Manufacturer</strong></td>
<td data-start="1171" data-end="1193" data-col-size="md">ProSoft Technology</td>
</tr>
<tr data-start="1194" data-end="1259">
<td data-start="1194" data-end="1212" data-col-size="sm"><strong data-start="1196" data-end="1211">Module Type</strong></td>
<td data-start="1212" data-end="1259" data-col-size="md">HART Multi-drop Master Communication Module</td>
</tr>
<tr data-start="1260" data-end="1319">
<td data-start="1260" data-end="1289" data-col-size="sm"><strong data-start="1262" data-end="1288">Platform Compatibility</strong></td>
<td data-start="1289" data-end="1319" data-col-size="md">Allen-Bradley ControlLogix</td>
</tr>
<tr data-start="1320" data-end="1362">
<td data-start="1320" data-end="1345" data-col-size="sm"><strong data-start="1322" data-end="1344">Communication Type</strong></td>
<td data-start="1345" data-end="1362" data-col-size="md">HART Protocol</td>
</tr>
<tr data-start="1363" data-end="1405">
<td data-start="1363" data-end="1378" data-col-size="sm"><strong data-start="1365" data-end="1377">Channels</strong></td>
<td data-start="1378" data-end="1405" data-col-size="md">4 Channels (Multi-drop)</td>
</tr>
<tr data-start="1406" data-end="1450">
<td data-start="1406" data-end="1426" data-col-size="sm"><strong data-start="1408" data-end="1425">Functionality</strong></td>
<td data-start="1426" data-end="1450" data-col-size="md">Master Communication</td>
</tr>
<tr data-start="1451" data-end="1500">
<td data-start="1451" data-end="1480" data-col-size="sm"><strong data-start="1453" data-end="1479">Backplane Current Load</strong></td>
<td data-start="1480" data-end="1500" data-col-size="md">800 mA @ 5.1 VDC</td>
</tr>
<tr data-start="1501" data-end="1542">
<td data-start="1501" data-end="1529" data-col-size="sm"><strong data-start="1503" data-end="1528">Operating Temperature</strong></td>
<td data-start="1529" data-end="1542" data-col-size="md">0 to 60&deg;C</td>
</tr>
<tr data-start="1543" data-end="1584">
<td data-start="1543" data-end="1569" data-col-size="sm"><strong data-start="1545" data-end="1568">Storage Temperature</strong></td>
<td data-start="1569" data-end="1584" data-col-size="md">-40 to 85&deg;C</td>
</tr>
<tr data-start="1585" data-end="1650">
<td data-start="1585" data-end="1608" data-col-size="sm"><strong data-start="1587" data-end="1607">Shock Resistance</strong></td>
<td data-start="1608" data-end="1650" data-col-size="md">30 g operational, 50 g non-operational</td>
</tr>
<tr data-start="1651" data-end="1700">
<td data-start="1651" data-end="1678" data-col-size="sm"><strong data-start="1653" data-end="1677">Vibration Resistance</strong></td>
<td data-start="1678" data-end="1700" data-col-size="md">5 g (10 to 150 Hz)</td>
</tr>
<tr data-start="1701" data-end="1755">
<td data-start="1701" data-end="1725" data-col-size="sm"><strong data-start="1703" data-end="1724">Relative Humidity</strong></td>
<td data-start="1725" data-end="1755" data-col-size="md">5% to 95% (non-condensing)</td>
</tr>
<tr data-start="1756" data-end="1806">
<td data-start="1756" data-end="1771" data-col-size="sm"><strong data-start="1758" data-end="1770">Mounting</strong></td>
<td data-start="1771" data-end="1806" data-col-size="md">ControlLogix Rack (Single Slot)</td>
</tr>
<tr data-start="1807" data-end="1851">
<td data-start="1807" data-end="1824" data-col-size="sm"><strong data-start="1809" data-end="1823">Dimensions</strong></td>
<td data-start="1824" data-end="1851" data-col-size="md">145.2 &times; 34.6 &times; 139.6 mm</td>
</tr>
<tr data-start="1852" data-end="1876">
<td data-start="1852" data-end="1865" data-col-size="sm"><strong data-start="1854" data-end="1864">Weight</strong></td>
<td data-start="1865" data-end="1876" data-col-size="md">0.31 kg</td>
</tr>
</tbody>
</table>
</div>
</div>
<hr data-start="1879" data-end="1884">
<h3 data-section-id="xdxar3" data-start="1885" data-end="1907"><span role="text"><strong data-start="1889" data-end="1905">Applications</strong></span></h3>
<p data-start="1909" data-end="2062">&#9679; <strong data-start="1911" data-end="1950">Process instrumentation integration</strong>, enabling direct communication with HART-enabled transmitters such as pressure, flow, and temperature devices</p>
<p data-start="2064" data-end="2173">&#9679; <strong data-start="2066" data-end="2100">Plant asset management systems</strong>, allowing access to advanced diagnostics and device configuration data</p>
<p data-start="2175" data-end="2279">&#9679; <strong data-start="2177" data-end="2214">Oil &amp; gas and chemical industries</strong>, where HART devices are widely used for monitoring and control</p>
<p data-start="2281" data-end="2386">&#9679; <strong data-start="2283" data-end="2308">SCADA and DCS systems</strong>, providing reliable acquisition of field-level data for centralized control</p>
<p data-start="2388" data-end="2492">&#9679; <strong data-start="2390" data-end="2424">Predictive maintenance systems</strong>, supporting real-time monitoring of device health and performance</p>
<p data-start="2494" data-end="2599">&#9679; <strong data-start="2496" data-end="2517">Retrofit projects</strong>, integrating existing HART field devices into modern ControlLogix architectures</p>
<hr data-start="2602" data-end="2607">
<h3 data-section-id="1cmhqn2" data-start="2608" data-end="2628"><span role="text"><strong data-start="2612" data-end="2626">Advantages</strong></span></h3>
<p data-start="2630" data-end="2733">&#9679; <strong data-start="2632" data-end="2666">Four independent HART channels</strong>, enabling simultaneous communication with multiple field devices</p>
<p data-start="2735" data-end="2825">&#9679; <strong data-start="2737" data-end="2762">Multi-drop capability</strong>, reducing wiring complexity and improving system scalability</p>
<p data-start="2827" data-end="2915">&#9679; <strong data-start="2829" data-end="2864">Direct ControlLogix integration</strong>, eliminating the need for external HART gateways</p>
<p data-start="2917" data-end="3008">&#9679; <strong data-start="2919" data-end="2950">Enhanced diagnostics access</strong>, allowing full utilization of smart device capabilities</p>
<p data-start="3010" data-end="3110">&#9679; <strong data-start="3012" data-end="3040">Robust industrial design</strong>, with high resistance to shock, vibration, and environmental stress</p>
<p data-start="3112" data-end="3216">&#9679; <strong data-start="3114" data-end="3144">Improved system visibility</strong>, supporting better decision-making through real-time data acquisition</p>
</body></html>
<p><a href="https://www.excellentplc.com/prosoft-mvi56-hart-multi-drop-master-communication-module/">ProSoft MVI56-HART Multi-drop Master Communication Module</a>最先出现在<a href="https://www.excellentplc.com">Excellent PLC</a>。</p>
]]></content:encoded>
					
					<wfw:commentRss>https://www.excellentplc.com/prosoft-mvi56-hart-multi-drop-master-communication-module/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
	</channel>
</rss>
