<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>MVI69-DFNT - Excellent PLC</title>
	<atom:link href="https://www.excellentplc.com/tag/mvi69-dfnt/feed/" rel="self" type="application/rss+xml" />
	<link>https://www.excellentplc.com/tag/mvi69-dfnt/</link>
	<description></description>
	<lastBuildDate>Wed, 08 Apr 2026 07:10:50 +0000</lastBuildDate>
	<language>zh-Hans</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.9.4</generator>

<image>
	<url>https://www.excellentplc.com/wp-content/uploads/2025/08/cropped-cropped-logo-192x192-1-32x32.jpg</url>
	<title>MVI69-DFNT - Excellent PLC</title>
	<link>https://www.excellentplc.com/tag/mvi69-dfnt/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>ProSoft MVI69-DFNT EtherNet/IP Client/Server Communication Module</title>
		<link>https://www.excellentplc.com/prosoft-mvi69-dfnt-ethernet-ip-client-server-communication-module/</link>
					<comments>https://www.excellentplc.com/prosoft-mvi69-dfnt-ethernet-ip-client-server-communication-module/#respond</comments>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Wed, 08 Apr 2026 07:10:50 +0000</pubDate>
				<category><![CDATA[Allen Bradley]]></category>
		<category><![CDATA[EtherNet/IP Client/Server Communication Module]]></category>
		<category><![CDATA[MVI69-DFNT]]></category>
		<category><![CDATA[ProSoft]]></category>
		<category><![CDATA[ProSoft MVI69-DFNT]]></category>
		<guid isPermaLink="false">https://www.excellentplc.com/?p=126551</guid>

					<description><![CDATA[<p>Product Introduction The ProSoft MVI69-DFNT is an Ether [&#8230;]</p>
<p><a href="https://www.excellentplc.com/prosoft-mvi69-dfnt-ethernet-ip-client-server-communication-module/">ProSoft MVI69-DFNT EtherNet/IP Client/Server Communication Module</a>最先出现在<a href="https://www.excellentplc.com">Excellent PLC</a>。</p>
]]></description>
										<content:encoded><![CDATA[<!DOCTYPE html PUBLIC "-//W3C//DTD HTML 4.0 Transitional//EN" "http://www.w3.org/TR/REC-html40/loose.dtd">
<html><body><h3 data-section-id="fp1bwt" data-start="6" data-end="36"><img fetchpriority="high" decoding="async" class="alignnone size-full wp-image-126552" src="https://www.excellentplc.com/wp-content/uploads/2026/04/MVI69-DFNT-1.jpg" alt="ProSoft MVI69-DFNT EtherNet/IP Client/Server Communication Module" width="800" height="800"></h3>
<h3 data-section-id="fp1bwt" data-start="6" data-end="36"><span role="text"><strong data-start="10" data-end="34">Product Introduction</strong></span></h3>
<p data-start="38" data-end="370">The ProSoft MVI69-DFNT is an EtherNet/IP Client/Server communication module designed to provide seamless network connectivity for Allen-Bradley CompactLogix and MicroLogix 1500 LRP processors. This module enables controllers to communicate efficiently with EtherNet/IP-compatible devices and host systems using explicit messaging.</p>
<p data-start="372" data-end="664">Installed as a single-slot solution, the MVI69-DFNT acts as a bridge between the PLC backplane and Ethernet networks. It allows processors that do not natively support advanced Ethernet communication to integrate into modern industrial networks without requiring major system modifications.</p>
<p data-start="666" data-end="1033">The module features a dedicated configuration port and a 10/100 Base-T Ethernet interface, ensuring straightforward setup and stable communication performance. Its compatibility with a wide range of CompactLogix processors, including L20, L30, L31, L32, L35, L43, and L45 series, makes it a flexible and practical solution for upgrading existing automation systems.</p>
<hr data-start="1036" data-end="1041">
<h3 data-section-id="10kfchv" data-start="1042" data-end="1074"><span role="text"><strong data-start="1046" data-end="1072">Product Specifications</strong></span></h3>
<div class="TyagGW_tableContainer">
<div class="group TyagGW_tableWrapper flex flex-col-reverse w-fit" tabindex="-1">
<table class="w-fit min-w-(--thread-content-width)" data-start="1076" data-end="1839">
<thead data-start="1076" data-end="1101">
<tr data-start="1076" data-end="1101">
<th class="" data-start="1076" data-end="1092" data-col-size="sm"><strong data-start="1078" data-end="1091">Parameter</strong></th>
<th class="" data-start="1092" data-end="1101" data-col-size="md">Value</th>
</tr>
</thead>
<tbody data-start="1125" data-end="1839">
<tr data-start="1125" data-end="1159">
<td data-start="1125" data-end="1145" data-col-size="sm"><strong data-start="1127" data-end="1144">Product Model</strong></td>
<td data-start="1145" data-end="1159" data-col-size="md">MVI69-DFNT</td>
</tr>
<tr data-start="1160" data-end="1201">
<td data-start="1160" data-end="1179" data-col-size="sm"><strong data-start="1162" data-end="1178">Manufacturer</strong></td>
<td data-start="1179" data-end="1201" data-col-size="md">ProSoft Technology</td>
</tr>
<tr data-start="1202" data-end="1270">
<td data-start="1202" data-end="1220" data-col-size="sm"><strong data-start="1204" data-end="1219">Module Type</strong></td>
<td data-start="1220" data-end="1270" data-col-size="md">EtherNet/IP Client/Server Communication Module</td>
</tr>
<tr data-start="1271" data-end="1367">
<td data-start="1271" data-end="1300" data-col-size="sm"><strong data-start="1273" data-end="1299">Platform Compatibility</strong></td>
<td data-start="1300" data-end="1367" data-col-size="md">CompactLogix (L20/L30/L31/L32/L35/L43/L45), MicroLogix 1500 LRP</td>
</tr>
<tr data-start="1368" data-end="1433">
<td data-start="1368" data-end="1397" data-col-size="sm"><strong data-start="1370" data-end="1396">Communication Protocol</strong></td>
<td data-start="1397" data-end="1433" data-col-size="md">EtherNet/IP (Explicit Messaging)</td>
</tr>
<tr data-start="1434" data-end="1489">
<td data-start="1434" data-end="1459" data-col-size="sm"><strong data-start="1436" data-end="1458">Configuration Port</strong></td>
<td data-start="1459" data-end="1489" data-col-size="md">1 &times; RJ45 Serial Port (CFG)</td>
</tr>
<tr data-start="1490" data-end="1538">
<td data-start="1490" data-end="1510" data-col-size="sm"><strong data-start="1492" data-end="1509">Ethernet Port</strong></td>
<td data-start="1510" data-end="1538" data-col-size="md">1 &times; RJ45 (10/100 Base-T)</td>
</tr>
<tr data-start="1539" data-end="1586">
<td data-start="1539" data-end="1568" data-col-size="sm"><strong data-start="1541" data-end="1567">Backplane Current Load</strong></td>
<td data-start="1568" data-end="1586" data-col-size="md">800 mA @ 5 VDC</td>
</tr>
<tr data-start="1587" data-end="1628">
<td data-start="1587" data-end="1615" data-col-size="sm"><strong data-start="1589" data-end="1614">Operating Temperature</strong></td>
<td data-start="1615" data-end="1628" data-col-size="md">0 to 60&deg;C</td>
</tr>
<tr data-start="1629" data-end="1670">
<td data-start="1629" data-end="1655" data-col-size="sm"><strong data-start="1631" data-end="1654">Storage Temperature</strong></td>
<td data-start="1655" data-end="1670" data-col-size="md">-40 to 85&deg;C</td>
</tr>
<tr data-start="1671" data-end="1725">
<td data-start="1671" data-end="1695" data-col-size="sm"><strong data-start="1673" data-end="1694">Relative Humidity</strong></td>
<td data-start="1695" data-end="1725" data-col-size="md">5% to 95% (non-condensing)</td>
</tr>
<tr data-start="1726" data-end="1776">
<td data-start="1726" data-end="1741" data-col-size="sm"><strong data-start="1728" data-end="1740">Mounting</strong></td>
<td data-start="1741" data-end="1776" data-col-size="md">Single Slot (CompactLogix Rack)</td>
</tr>
<tr data-start="1777" data-end="1814">
<td data-start="1777" data-end="1794" data-col-size="sm"><strong data-start="1779" data-end="1793">Dimensions</strong></td>
<td data-start="1794" data-end="1814" data-col-size="md">118 &times; 35 &times; 87 mm</td>
</tr>
<tr data-start="1815" data-end="1839">
<td data-start="1815" data-end="1828" data-col-size="sm"><strong data-start="1817" data-end="1827">Weight</strong></td>
<td data-start="1828" data-end="1839" data-col-size="md">0.45 kg</td>
</tr>
</tbody>
</table>
</div>
</div>
<hr data-start="1842" data-end="1847">
<h3 data-section-id="xdxar3" data-start="1848" data-end="1870"><span role="text"><strong data-start="1852" data-end="1868">Applications</strong></span></h3>
<p data-start="1872" data-end="2030">&#9679; <strong data-start="1874" data-end="1937">Integration of legacy PLC systems into EtherNet/IP networks</strong>, enabling older CompactLogix and MicroLogix controllers to communicate with modern devices</p>
<p data-start="2032" data-end="2144">&#9679; <strong data-start="2034" data-end="2064">SCADA and HMI connectivity</strong>, allowing efficient data exchange between controllers and supervisory systems</p>
<p data-start="2146" data-end="2271">&#9679; <strong data-start="2148" data-end="2180">Industrial network expansion</strong>, supporting communication with remote I/O, drives, and intelligent devices over Ethernet</p>
<p data-start="2273" data-end="2383">&#9679; <strong data-start="2275" data-end="2303">Data acquisition systems</strong>, enabling collection of real-time operational data through explicit messaging</p>
<p data-start="2385" data-end="2494">&#9679; <strong data-start="2387" data-end="2420">System upgrades and retrofits</strong>, minimizing hardware changes while enhancing communication capabilities</p>
<p data-start="2496" data-end="2617">&#9679; <strong data-start="2498" data-end="2538">Interfacing with third-party devices</strong>, ensuring compatibility with EtherNet/IP-enabled instruments and controllers</p>
<hr data-start="2620" data-end="2625">
<h3 data-section-id="1cmhqn2" data-start="2626" data-end="2646"><span role="text"><strong data-start="2630" data-end="2644">Advantages</strong></span></h3>
<p data-start="2648" data-end="2744">&#9679; <strong data-start="2650" data-end="2683">Broad processor compatibility</strong>, supporting multiple CompactLogix and MicroLogix platforms</p>
<p data-start="2746" data-end="2839">&#9679; <strong data-start="2748" data-end="2790">EtherNet/IP explicit messaging support</strong>, enabling flexible and efficient data exchange</p>
<p data-start="2841" data-end="2934">&#9679; <strong data-start="2843" data-end="2865">Simple integration</strong>, requiring only a single slot without additional external gateways</p>
<p data-start="2936" data-end="3017">&#9679; <strong data-start="2938" data-end="2973">Reliable Ethernet communication</strong>, with standard 10/100 Base-T connectivity</p>
<p data-start="3019" data-end="3094">&#9679; <strong data-start="3021" data-end="3053">Dedicated configuration port</strong>, simplifying setup and troubleshooting</p>
<p data-start="3096" data-end="3188">&#9679; <strong data-start="3098" data-end="3116">Compact design</strong>, saving panel space while delivering full communication functionality</p>
</body></html>
<p><a href="https://www.excellentplc.com/prosoft-mvi69-dfnt-ethernet-ip-client-server-communication-module/">ProSoft MVI69-DFNT EtherNet/IP Client/Server Communication Module</a>最先出现在<a href="https://www.excellentplc.com">Excellent PLC</a>。</p>
]]></content:encoded>
					
					<wfw:commentRss>https://www.excellentplc.com/prosoft-mvi69-dfnt-ethernet-ip-client-server-communication-module/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
	</channel>
</rss>
