<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>ProSoft MVI46-MCM - Excellent PLC</title>
	<atom:link href="https://www.excellentplc.com/tag/prosoft-mvi46-mcm/feed/" rel="self" type="application/rss+xml" />
	<link>https://www.excellentplc.com/tag/prosoft-mvi46-mcm/</link>
	<description></description>
	<lastBuildDate>Wed, 08 Apr 2026 03:57:36 +0000</lastBuildDate>
	<language>zh-Hans</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.9.4</generator>

<image>
	<url>https://www.excellentplc.com/wp-content/uploads/2025/08/cropped-cropped-logo-192x192-1-32x32.jpg</url>
	<title>ProSoft MVI46-MCM - Excellent PLC</title>
	<link>https://www.excellentplc.com/tag/prosoft-mvi46-mcm/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>ProSoft MVI46-MCM Modbus Master/Slave Communication Module</title>
		<link>https://www.excellentplc.com/prosoft-mvi46-mcm-modbus-master-slave-communication-module/</link>
					<comments>https://www.excellentplc.com/prosoft-mvi46-mcm-modbus-master-slave-communication-module/#respond</comments>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Wed, 08 Apr 2026 03:57:01 +0000</pubDate>
				<category><![CDATA[Allen Bradley]]></category>
		<category><![CDATA[Modbus Master/Slave Communication Module]]></category>
		<category><![CDATA[MVI46-MCM]]></category>
		<category><![CDATA[ProSoft]]></category>
		<category><![CDATA[ProSoft MVI46-MCM]]></category>
		<guid isPermaLink="false">https://www.excellentplc.com/?p=126530</guid>

					<description><![CDATA[<p>Product Introduction The ProSoft MVI46-MCM is a Modbus  [&#8230;]</p>
<p><a href="https://www.excellentplc.com/prosoft-mvi46-mcm-modbus-master-slave-communication-module/">ProSoft MVI46-MCM Modbus Master/Slave Communication Module</a>最先出现在<a href="https://www.excellentplc.com">Excellent PLC</a>。</p>
]]></description>
										<content:encoded><![CDATA[<!DOCTYPE html PUBLIC "-//W3C//DTD HTML 4.0 Transitional//EN" "http://www.w3.org/TR/REC-html40/loose.dtd">
<html><body><h3 data-section-id="fp1bwt" data-start="6" data-end="36"><img fetchpriority="high" decoding="async" class="alignnone size-full wp-image-126531" src="https://www.excellentplc.com/wp-content/uploads/2026/04/MVI46-MCM-1.jpg" alt="ProSoft MVI46-MCM Modbus Master/Slave Communication Module" width="800" height="800"></h3>
<h3 data-section-id="fp1bwt" data-start="6" data-end="36"><span role="text"><strong data-start="10" data-end="34">Product Introduction</strong></span></h3>
<p data-start="38" data-end="346">The ProSoft MVI46-MCM is a Modbus Master/Slave communication module designed for Allen-Bradley SLC and CompactLogix processors. This module provides a seamless interface between the PLC backplane and Modbus-compatible devices, enabling efficient and reliable data exchange in industrial automation systems.</p>
<p data-start="348" data-end="664">Equipped with both Master and Slave functionality, the MVI46-MCM allows the PLC to actively poll Modbus devices while simultaneously responding to requests from other Masters. This flexibility makes it suitable for complex distributed control systems and applications where multiple communication roles are needed.</p>
<p data-start="666" data-end="1054">The module features dual communication ports supporting RS-232, RS-422, and RS-485 connections, along with a dedicated configuration port (RJ45) for setup and diagnostics. Its robust design ensures stable operation under industrial environmental conditions, including moderate vibration and temperature ranges, making it ideal for manufacturing, process control, and factory automation.</p>
<hr data-start="1056" data-end="1061">
<h3 data-section-id="10kfchv" data-start="1062" data-end="1094"><span role="text"><strong data-start="1066" data-end="1092">Product Specifications</strong></span></h3>
<div class="TyagGW_tableContainer">
<div class="group TyagGW_tableWrapper flex flex-col-reverse w-fit" tabindex="-1">
<table class="w-fit min-w-(--thread-content-width)" data-start="1096" data-end="1813">
<thead data-start="1096" data-end="1121">
<tr data-start="1096" data-end="1121">
<th class="" data-start="1096" data-end="1112" data-col-size="sm"><strong data-start="1098" data-end="1111">Parameter</strong></th>
<th class="" data-start="1112" data-end="1121" data-col-size="sm">Value</th>
</tr>
</thead>
<tbody data-start="1145" data-end="1813">
<tr data-start="1145" data-end="1178">
<td data-start="1145" data-end="1165" data-col-size="sm"><strong data-start="1147" data-end="1164">Product Model</strong></td>
<td data-start="1165" data-end="1178" data-col-size="sm">MVI46-MCM</td>
</tr>
<tr data-start="1179" data-end="1220">
<td data-start="1179" data-end="1198" data-col-size="sm"><strong data-start="1181" data-end="1197">Manufacturer</strong></td>
<td data-start="1198" data-end="1220" data-col-size="sm">ProSoft Technology</td>
</tr>
<tr data-start="1221" data-end="1283">
<td data-start="1221" data-end="1239" data-col-size="sm"><strong data-start="1223" data-end="1238">Module Type</strong></td>
<td data-start="1239" data-end="1283" data-col-size="sm">Modbus Master/Slave Communication Module</td>
</tr>
<tr data-start="1284" data-end="1327">
<td data-start="1284" data-end="1304" data-col-size="sm"><strong data-start="1286" data-end="1303">Functionality</strong></td>
<td data-start="1304" data-end="1327" data-col-size="sm">Modbus Master/Slave</td>
</tr>
<tr data-start="1328" data-end="1393">
<td data-start="1328" data-end="1357" data-col-size="sm"><strong data-start="1330" data-end="1356">Platform Compatibility</strong></td>
<td data-start="1357" data-end="1393" data-col-size="sm">Allen-Bradley SLC / ControlLogix</td>
</tr>
<tr data-start="1394" data-end="1447">
<td data-start="1394" data-end="1419" data-col-size="sm"><strong data-start="1396" data-end="1418">Configuration Port</strong></td>
<td data-start="1419" data-end="1447" data-col-size="sm">1 &times; RJ45 RS-232 (CONFIG)</td>
</tr>
<tr data-start="1448" data-end="1510">
<td data-start="1448" data-end="1474" data-col-size="sm"><strong data-start="1450" data-end="1473">Communication Ports</strong></td>
<td data-start="1474" data-end="1510" data-col-size="sm">2 &times; RJ45 RS-232/422/485 (Modbus)</td>
</tr>
<tr data-start="1511" data-end="1549">
<td data-start="1511" data-end="1534" data-col-size="sm"><strong data-start="1513" data-end="1533">Slot Requirement</strong></td>
<td data-start="1534" data-end="1549" data-col-size="sm">Single Slot</td>
</tr>
<tr data-start="1550" data-end="1604">
<td data-start="1550" data-end="1577" data-col-size="sm"><strong data-start="1552" data-end="1576">Data Exchange Method</strong></td>
<td data-start="1577" data-end="1604" data-col-size="sm">Backplane I/O Interface</td>
</tr>
<tr data-start="1605" data-end="1646">
<td data-start="1605" data-end="1633" data-col-size="sm"><strong data-start="1607" data-end="1632">Operating Temperature</strong></td>
<td data-start="1633" data-end="1646" data-col-size="sm">0 to 60&deg;C</td>
</tr>
<tr data-start="1647" data-end="1693">
<td data-start="1647" data-end="1674" data-col-size="sm"><strong data-start="1649" data-end="1673">Vibration Resistance</strong></td>
<td data-start="1674" data-end="1693" data-col-size="sm">5 g (10&ndash;150 Hz)</td>
</tr>
<tr data-start="1694" data-end="1743">
<td data-start="1694" data-end="1723" data-col-size="sm"><strong data-start="1696" data-end="1722">Backplane Current Load</strong></td>
<td data-start="1723" data-end="1743" data-col-size="sm">800 mA @ 5.1 VDC</td>
</tr>
<tr data-start="1744" data-end="1788">
<td data-start="1744" data-end="1761" data-col-size="sm"><strong data-start="1746" data-end="1760">Dimensions</strong></td>
<td data-start="1761" data-end="1788" data-col-size="sm">144.5 &times; 34.6 &times; 130.18 mm</td>
</tr>
<tr data-start="1789" data-end="1813">
<td data-start="1789" data-end="1802" data-col-size="sm"><strong data-start="1791" data-end="1801">Weight</strong></td>
<td data-start="1802" data-end="1813" data-col-size="sm">0.16 kg</td>
</tr>
</tbody>
</table>
</div>
</div>
<hr data-start="1816" data-end="1821">
<h3 data-section-id="xdxar3" data-start="1822" data-end="1844"><span role="text"><strong data-start="1826" data-end="1842">Applications</strong></span></h3>
<p data-start="1846" data-end="1970">&#9679; <strong data-start="1848" data-end="1910">SLC/ControlLogix integration with Modbus RTU/ASCII devices</strong>, allowing smooth communication across industrial networks</p>
<p data-start="1972" data-end="2087">&#9679; <strong data-start="1974" data-end="2005">Distributed control systems</strong>, enabling Master/Slave communication with multiple field devices simultaneously</p>
<p data-start="2089" data-end="2195">&#9679; <strong data-start="2091" data-end="2113">Process automation</strong>, such as manufacturing lines, energy monitoring, and water treatment facilities</p>
<p data-start="2197" data-end="2302">&#9679; <strong data-start="2199" data-end="2231">SCADA and monitoring systems</strong>, providing reliable data exchange for remote acquisition and control</p>
<p data-start="2304" data-end="2430">&#9679; <strong data-start="2306" data-end="2325">I/O integration</strong>, allowing the PLC to read and write data to multiple Modbus-compatible devices through a single module</p>
<p data-start="2432" data-end="2559">&#9679; <strong data-start="2434" data-end="2454">System retrofits</strong>, connecting modern Allen-Bradley controllers with existing Modbus networks without additional gateways</p>
<hr data-start="2562" data-end="2567">
<h3 data-section-id="1cmhqn2" data-start="2568" data-end="2588"><span role="text"><strong data-start="2572" data-end="2586">Advantages</strong></span></h3>
<p data-start="2590" data-end="2696">&#9679; <strong data-start="2592" data-end="2624">Dual Master/Slave capability</strong>, offering flexible network communication roles within the same module</p>
<p data-start="2698" data-end="2812">&#9679; <strong data-start="2700" data-end="2732">Multiple communication ports</strong>, supporting RS-232, RS-422, and RS-485, enabling versatile connection options</p>
<p data-start="2814" data-end="2906">&#9679; <strong data-start="2816" data-end="2848">Dedicated configuration port</strong>, allowing easy setup, diagnostics, and firmware updates</p>
<p data-start="2908" data-end="3015">&#9679; <strong data-start="2910" data-end="2935">Backplane integration</strong>, eliminating the need for external protocol converters and simplifying wiring</p>
<p data-start="3017" data-end="3129">&#9679; <strong data-start="3019" data-end="3047">Robust industrial design</strong>, capable of withstanding moderate vibration and standard operating temperatures</p>
<p data-start="3131" data-end="3221">&#9679; <strong data-start="3133" data-end="3165">Compact single-slot solution</strong>, saving rack space while providing full functionality</p>
</body></html>
<p><a href="https://www.excellentplc.com/prosoft-mvi46-mcm-modbus-master-slave-communication-module/">ProSoft MVI46-MCM Modbus Master/Slave Communication Module</a>最先出现在<a href="https://www.excellentplc.com">Excellent PLC</a>。</p>
]]></content:encoded>
					
					<wfw:commentRss>https://www.excellentplc.com/prosoft-mvi46-mcm-modbus-master-slave-communication-module/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
	</channel>
</rss>
