<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>ProSoft MVI69-FLN - Excellent PLC</title>
	<atom:link href="https://www.excellentplc.com/tag/prosoft-mvi69-fln/feed/" rel="self" type="application/rss+xml" />
	<link>https://www.excellentplc.com/tag/prosoft-mvi69-fln/</link>
	<description></description>
	<lastBuildDate>Wed, 08 Apr 2026 03:42:20 +0000</lastBuildDate>
	<language>zh-Hans</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.9.4</generator>

<image>
	<url>https://www.excellentplc.com/wp-content/uploads/2025/08/cropped-cropped-logo-192x192-1-32x32.jpg</url>
	<title>ProSoft MVI69-FLN - Excellent PLC</title>
	<link>https://www.excellentplc.com/tag/prosoft-mvi69-fln/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>ProSoft MVI69-FLN FL-Net Network Interface Module</title>
		<link>https://www.excellentplc.com/prosoft-mvi69-fln-fl-net-network-interface-module/</link>
					<comments>https://www.excellentplc.com/prosoft-mvi69-fln-fl-net-network-interface-module/#respond</comments>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Wed, 08 Apr 2026 03:42:20 +0000</pubDate>
				<category><![CDATA[Allen Bradley]]></category>
		<category><![CDATA[FL-Net Network Interface Module]]></category>
		<category><![CDATA[MVI69-FLN]]></category>
		<category><![CDATA[ProSoft]]></category>
		<category><![CDATA[ProSoft MVI69-FLN]]></category>
		<guid isPermaLink="false">https://www.excellentplc.com/?p=126524</guid>

					<description><![CDATA[<p>Product Introduction The ProSoft MVI69-FLN is a FL-net  [&#8230;]</p>
<p><a href="https://www.excellentplc.com/prosoft-mvi69-fln-fl-net-network-interface-module/">ProSoft MVI69-FLN FL-Net Network Interface Module</a>最先出现在<a href="https://www.excellentplc.com">Excellent PLC</a>。</p>
]]></description>
										<content:encoded><![CDATA[<!DOCTYPE html PUBLIC "-//W3C//DTD HTML 4.0 Transitional//EN" "http://www.w3.org/TR/REC-html40/loose.dtd">
<html><body><h3 data-section-id="fp1bwt" data-start="6" data-end="36"><img fetchpriority="high" decoding="async" class="alignnone size-full wp-image-126525" src="https://www.excellentplc.com/wp-content/uploads/2026/04/MVI69-FLN-1.jpg" alt="ProSoft MVI69-FLN FL-Net Network Interface Module" width="800" height="800"></h3>
<h3 data-section-id="fp1bwt" data-start="6" data-end="36"><span role="text"><strong data-start="10" data-end="34">Product Introduction</strong></span></h3>
<p data-start="38" data-end="445">The ProSoft MVI69-FLN is a FL-net network interface communication module designed for Rockwell Automation CompactLogix and MicroLogix processors. This single-slot module enables seamless communication with FL-net protocol-compatible devices, following the FL-net version 2.00 (OPCN-2) specification defined by JEMA (Japan Electrical Manufacturers Association) for factory automation (FA) control networks.</p>
<p data-start="447" data-end="757">As a gateway, the MVI69-FLN interfaces between the FL-net network and the CompactLogix/MicroLogix backplane. It facilitates asynchronous data transfer, ensuring that operations on the FL-net network and PLC actions remain decoupled, maintaining reliable communication without interfering with network timing.</p>
<p data-start="759" data-end="1191">The module manages Area 1 and Area 2 cyclic data, network data, and module status information through its internal database. It enables peer-to-peer communication on FL-net, where all devices share two fixed-size databases. The MVI69-FLN accepts commands to monitor, control, and transfer this data between the FL-net network and the PLC processor, allowing users to implement high-performance automation applications efficiently.</p>
<hr data-start="1194" data-end="1199">
<h3 data-section-id="10kfchv" data-start="1200" data-end="1232"><span role="text"><strong data-start="1204" data-end="1230">Product Specifications</strong></span></h3>
<div class="TyagGW_tableContainer">
<div class="group TyagGW_tableWrapper flex flex-col-reverse w-fit" tabindex="-1">
<table class="w-fit min-w-(--thread-content-width)" data-start="1234" data-end="1928">
<thead data-start="1234" data-end="1259">
<tr data-start="1234" data-end="1259">
<th class="" data-start="1234" data-end="1250" data-col-size="sm"><strong data-start="1236" data-end="1249">Parameter</strong></th>
<th class="" data-start="1250" data-end="1259" data-col-size="sm">Value</th>
</tr>
</thead>
<tbody data-start="1283" data-end="1928">
<tr data-start="1283" data-end="1316">
<td data-start="1283" data-end="1303" data-col-size="sm"><strong data-start="1285" data-end="1302">Product Model</strong></td>
<td data-start="1303" data-end="1316" data-col-size="sm">MVI69-FLN</td>
</tr>
<tr data-start="1317" data-end="1358">
<td data-start="1317" data-end="1336" data-col-size="sm"><strong data-start="1319" data-end="1335">Manufacturer</strong></td>
<td data-start="1336" data-end="1358" data-col-size="sm">ProSoft Technology</td>
</tr>
<tr data-start="1359" data-end="1412">
<td data-start="1359" data-end="1377" data-col-size="sm"><strong data-start="1361" data-end="1376">Module Type</strong></td>
<td data-start="1377" data-end="1412" data-col-size="sm">FL-net Network Interface Module</td>
</tr>
<tr data-start="1413" data-end="1469">
<td data-start="1413" data-end="1433" data-col-size="sm"><strong data-start="1415" data-end="1432">Functionality</strong></td>
<td data-start="1433" data-end="1469" data-col-size="sm">FA Control Network Communication</td>
</tr>
<tr data-start="1470" data-end="1528">
<td data-start="1470" data-end="1499" data-col-size="sm"><strong data-start="1472" data-end="1498">Platform Compatibility</strong></td>
<td data-start="1499" data-end="1528" data-col-size="sm">CompactLogix / MicroLogix</td>
</tr>
<tr data-start="1529" data-end="1577">
<td data-start="1529" data-end="1552" data-col-size="sm"><strong data-start="1531" data-end="1551">Protocol Support</strong></td>
<td data-start="1552" data-end="1577" data-col-size="sm">FL-net v2.00 (OPCN-2)</td>
</tr>
<tr data-start="1578" data-end="1616">
<td data-start="1578" data-end="1601" data-col-size="sm"><strong data-start="1580" data-end="1600">Slot Requirement</strong></td>
<td data-start="1601" data-end="1616" data-col-size="sm">Single Slot</td>
</tr>
<tr data-start="1617" data-end="1658">
<td data-start="1617" data-end="1645" data-col-size="sm"><strong data-start="1619" data-end="1644">Operating Temperature</strong></td>
<td data-start="1645" data-end="1658" data-col-size="sm">0 to 60&deg;C</td>
</tr>
<tr data-start="1659" data-end="1700">
<td data-start="1659" data-end="1685" data-col-size="sm"><strong data-start="1661" data-end="1684">Storage Temperature</strong></td>
<td data-start="1685" data-end="1700" data-col-size="sm">&ndash;40 to 85&deg;C</td>
</tr>
<tr data-start="1701" data-end="1755">
<td data-start="1701" data-end="1725" data-col-size="sm"><strong data-start="1703" data-end="1724">Relative Humidity</strong></td>
<td data-start="1725" data-end="1755" data-col-size="sm">5% to 95% (non-condensing)</td>
</tr>
<tr data-start="1756" data-end="1810">
<td data-start="1756" data-end="1776" data-col-size="sm"><strong data-start="1758" data-end="1775">Mounting Type</strong></td>
<td data-start="1776" data-end="1810" data-col-size="sm">CompactLogix / MicroLogix Rack</td>
</tr>
<tr data-start="1811" data-end="1865">
<td data-start="1811" data-end="1838" data-col-size="sm"><strong data-start="1813" data-end="1837">Data Exchange Method</strong></td>
<td data-start="1838" data-end="1865" data-col-size="sm">Backplane I/O Interface</td>
</tr>
<tr data-start="1866" data-end="1903">
<td data-start="1866" data-end="1883" data-col-size="sm"><strong data-start="1868" data-end="1882">Dimensions</strong></td>
<td data-start="1883" data-end="1903" data-col-size="sm">118 &times; 35 &times; 87 mm</td>
</tr>
<tr data-start="1904" data-end="1928">
<td data-start="1904" data-end="1917" data-col-size="sm"><strong data-start="1906" data-end="1916">Weight</strong></td>
<td data-start="1917" data-end="1928" data-col-size="sm">0.28 kg</td>
</tr>
</tbody>
</table>
</div>
</div>
<hr data-start="1931" data-end="1936">
<h3 data-section-id="xdxar3" data-start="1937" data-end="1959"><span role="text"><strong data-start="1941" data-end="1957">Applications</strong></span></h3>
<p data-start="1961" data-end="2092">&#9679; <strong data-start="1963" data-end="2023">CompactLogix/MicroLogix integration with FL-net networks</strong>, enabling efficient communication with peer-to-peer FL-net devices</p>
<p data-start="2094" data-end="2214">&#9679; <strong data-start="2096" data-end="2126">Factory automation systems</strong>, providing connectivity to FA-compatible devices such as PLCs, sensors, and actuators</p>
<p data-start="2216" data-end="2319">&#9679; <strong data-start="2218" data-end="2248">Asynchronous data exchange</strong>, ensuring PLC operations do not interfere with FL-net network timing</p>
<p data-start="2321" data-end="2438">&#9679; <strong data-start="2323" data-end="2361">Cyclic and network data management</strong>, allowing exchange of Area 1 and Area 2 data and module status information</p>
<p data-start="2440" data-end="2557">&#9679; <strong data-start="2442" data-end="2473">High-performance automation</strong>, supporting FA control networks where multiple devices share fixed-size databases</p>
<p data-start="2559" data-end="2694">&#9679; <strong data-start="2561" data-end="2581">System retrofits</strong>, enabling modern CompactLogix processors to interface with existing FL-net devices without additional hardware</p>
<hr data-start="2697" data-end="2702">
<h3 data-section-id="1cmhqn2" data-start="2703" data-end="2723"><span role="text"><strong data-start="2707" data-end="2721">Advantages</strong></span></h3>
<p data-start="2725" data-end="2830">&#9679; <strong data-start="2727" data-end="2757">Single-slot compact design</strong>, saving rack space while providing full FL-net interface functionality</p>
<p data-start="2832" data-end="2925">&#9679; <strong data-start="2834" data-end="2858">FL-net v2.00 support</strong>, ensuring compliance with standardized FA network specifications</p>
<p data-start="2927" data-end="3024">&#9679; <strong data-start="2929" data-end="2959">Peer-to-peer communication</strong>, allowing multiple devices to interact directly on the network</p>
<p data-start="3026" data-end="3121">&#9679; <strong data-start="3028" data-end="3054">Asynchronous operation</strong>, preventing network activity from affecting PLC execution timing</p>
<p data-start="3123" data-end="3224">&#9679; <strong data-start="3125" data-end="3157">Internal database management</strong>, enabling easy access to cyclic, network, and module status data</p>
<p data-start="3226" data-end="3336">&#9679; <strong data-start="3228" data-end="3252">Robust compatibility</strong>, supporting both CompactLogix and MicroLogix processors for versatile integration</p>
</body></html>
<p><a href="https://www.excellentplc.com/prosoft-mvi69-fln-fl-net-network-interface-module/">ProSoft MVI69-FLN FL-Net Network Interface Module</a>最先出现在<a href="https://www.excellentplc.com">Excellent PLC</a>。</p>
]]></content:encoded>
					
					<wfw:commentRss>https://www.excellentplc.com/prosoft-mvi69-fln-fl-net-network-interface-module/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
	</channel>
</rss>
